43 resultados para Urban Regeneration
Resumo:
The dewatering of iron ore concentrates requires large capacity in addition to producing a cake with low moisture content. Such large processes are commonly energy intensive and means to lower the specific energy consumption are needed. Ceramic capillary action disc filters incorporate a novel filter medium enabling the harnessing of capillary action, which results in decreased energy consumption in comparison to traditional filtration technologies. As another benefit, the filter medium is mechanically and chemically more durable than, for example, filter cloths and can, thus, withstand harsh operating conditions and possible regeneration better than other types of filter media. In iron ore dewatering, the regeneration of the filter medium is done through a combination of several techniques: (1) backwashing, (2) ultrasonic cleaning, and (3) acid regeneration. Although it is commonly acknowledged that the filter medium is affected by slurry particles and extraneous compounds, published research, especially in the field of dewatering of mineral concentrates, is scarce. Whereas the regenerative effect of backwashing and ultrasound are more or less mechanical, regeneration with acids is based on chemistry. The chemistry behind the acid regeneration is, naturally, dissolution. The dissolution of iron oxide particles has been extensively studied over several decades but those studies may not necessarily be directly applicable in the regeneration of the filter medium which has undergone interactions with the slurry components. The aim of this thesis was to investigate if free particle dissolution indeed correlates with the regeneration of the filter medium. For this purpose, both free particle dissolution and dissolution of surface adhered particles were studied. The focus was on acidic dissolution of iron oxide particles and on the study of the ceramic filter medium used in the dewatering of iron ore concentrates. The free particle dissolution experiments show that the solubility of synthetic fine grained iron oxide particles in oxalic acid could be explained through linear models accounting for the effects of temperature and acid concentration, whereas the dissolution of a natural magnetite is not so easily explained by such models. In addition, the kinetic experiments performed both support and contradict the work of previous authors: the suitable kinetic model here supports previous research suggesting solid state reduction to be the reaction mechanism of hematite dissolution but the formation of a stable iron oxalate is not supported by the results of this research. Several other dissolution mechanisms have also been suggested for iron oxide dissolution in oxalic acid, indicating that the details of oxalate promoted reductive dissolution are not yet agreed and, in this respect, this research offers added value to the community. The results of the regeneration experiments with the ceramic filter media show that oxalic acid is highly effective in removing iron oxide particles from the surface of the filter medium. The dissolution of those particles did not, however, exhibit the expected behaviour, i.e. complete dissolution. The results of this thesis show that although the regeneration of the ceramic filter medium with acids incorporates the dissolution of slurry particles from the surface of the filter medium, the regeneration cannot be assessed purely based upon free particle dissolution. A steady state, dependent on temperature and on the acid concentration, was observed in the dissolution of particles from the surface even though the limit of solubility of free iron oxide particles had not been reached. Both the regeneration capacity and efficiency, with regards to the removal of iron oxide particles, was found to be temperature dependent, but was not affected by the acid concentration. This observation further suggests that the removal of the surface adhered particles does not follow the dissolution of free particles, which do exhibit a dependency on the acid concentration. In addition, changes in the permeability and in the pore structure of the filter medium were still observed after the bulk concentration of dissolved iron had reached a steady state. Consequently, the regeneration of the filter medium continued after the dissolution of particles from the surface had ceased. This observation suggests that internal changes take place at the final stages of regeneration. The regeneration process could, in theory, be divided into two, possibly overlapping, stages: (1) dissolution of surface-adhered particles, and (2) dissolution of extraneous compounds from within the pore structure. In addition to the fundamental knowledge generated during this thesis, tools to assess the effects of parameters on the regeneration of the ceramic filter medium are needed. It has become clear that the same tools used to estimate the dissolution of free particles cannot be used to estimate the regeneration of a filter medium unless only a robust characterisation of the order of regeneration efficiency is needed.
Resumo:
This thesis examines partnerships in sustainable urban development projects. Achievement of urban development requires the involvement of several parties. The cooperation of the actors of sustainable urban development is achieved by forming partnerships. The purpose of this study is to find solutions and best practices for the management of partnerships in sustainable residential development projects by examining partnerships and their success factors in sustainable urban development. The impact of the roles, responsibilities and interactions of actors taking part in the processes of creating sustainable urban development in outcomes of these development projects and thus on the overall success of accomplishing sustainable development raises the question of how to manage these collaborations. In order to be able to find the best ways of organizing sustainable urban development projects, it is crucial to have the knowledge of how the interactions between all the parties involved in the development can be managed successfully to give the best outcomes. The main research question of this study is: What are the characteristics of successful partnerships in sustainable urban development projects? In order to answer this question, the success factors in partnerships between actors of sustainable urban development are analyzed. In addition, challenges related to these partnerships are examined to get a more comprehensive view of the features of these collaborative ventures and the obstacles that have to be overcome to ensure the successfulness of cooperation. The research approach is multiple case study comprising four cases. The empirical data has been gathered through theme interviews from four different sustainable residential district projects in Sweden and Finland. A comparative analysis of the cases is performed, based on which seven success factors of partnerships in sustainable urban development supported by the prevailing theories are formulated. In addition, challenges faced by projects regarding the partnerships are discussed.
Resumo:
Ammonia can be used as a pH controller in chloride-based metal recovery processes. In chloride conditions, ammonia reacts to ammonium chloride which can be regenerated back to ammonia with lime. Although the regeneration process itself has been known for a long time, the concentrations, non-reacting species, conditions, and even goals are different when comparing the ammonia regeneration process in different industries. The main objective of this thesis was to study the phenomena, equipment, and challenges in ammonia regeneration in the nickel process and to make a preliminary process design. The study concentrated on the regeneration and recovery units. The thesis was made by process simulation and laboratory tests using the current processes as initial information. The results were combined from all of the information obtained during the studies to provide a total process solution, which can be used as a basis when designing an ammonia regeneration process to be used in industry. In particular, it was possible to determine ammonia recovery with a stripping column and the achievement of the desired ammonia water product within the scope of this thesis. The required mass flows and process conditions were also determined. The possible challenges and solutions or further studies to overcome them were provided as well to ease the prediction and design of the ammonia regeneration process in the future. On the basis of the results of this thesis, the ammonia regeneration process can be developed further and implemented in the nickel chloride leaching process.
Resumo:
As the rapid development of the society as well as the lifestyle, the generation of commercial waste is getting more complicated to control. The situation of packaging waste and food waste – the main fractions of commercial waste in different countries in Europe and Asia is analyzed in order to evaluate and suggest necessary improvements for the existing waste management system in the city of Hanoi, Vietnam. From all waste generation sources of the city, a total amount of approximately 4000 tons of mixed waste is transported to the composting facility and the disposal site, which emits a huge amount of 1,6Mt of GHG emission to the environment. Recycling activity is taking place spontaneously by the informal pickers, leads to the difficulty in managing the whole system and uncertainty of the overall data. With a relative calculation, resulting in only approximately 0,17Mt CO2 equivalent emission, incinerator is suggested to be the solution of the problem with overloaded landfill and raising energy demand within the inhabitants.
Resumo:
The term urban heat island (UHI) refers to the common situation in which the city is warmer than its rural surroundings. In this dissertation, the local climate, and especially the UHI, of the coastal city of Turku (182,000 inh.), SW Finland, was studied in different spatial and temporal scales. The crucial aim was to sort out the urban, topographical and water body impact on temperatures at different seasons and times of the day. In addition, the impact of weather on spatiotemporal temperature differences was studied. The relative importance of environmental factors was estimated with different modelling approaches and a large number of explanatory variables with various spatial scales. The city centre is the warmest place in the Turku area. Temperature excess relative to the coldest sites, i.e. rural areas about 10 kilometers to the NE from the centre, is on average 2 °C. Occasionally, the UHI intensity can be even 10 °C. The UHI does not prevail continuously in the Turku area, but occasionally the city centre can be colder than its surroundings. Then the term urban cool island or urban cold island (UCI) is used. The UCI is most common in daytime in spring and in summer, whereas during winter the UHI prevails throughout the day. On average, the spatial temperature differences are largest in summer, whereas the single extreme values are often observed in winter. The seasonally varying sea temperature causes the shift of relatively warm areas towards the coast in autumn and inland in spring. In the long term, urban land use was concluded to be the most important factor causing spatial temperature differences in the Turku area. The impact was mainly a warming one. The impact of water bodies was emphasised in spring and autumn, when the water temperature was relatively cold and warm, respectively. The impact of topography was on average the weakest, and was seen mainly in proneness of relatively low-lying places for cold air drainage during night-time. During inversions, however, the impact of topography was emphasised, occasionally outperforming those of urban land use and water bodies.
Resumo:
A direct-driven permanent magnet synchronous machine for a small urban use electric vehicle is presented. The measured performance of the machine at the test bench as well as the performance over the modified New European Drive Cycle will be given. The effect of optimal current components, maximizing the efficiency and taking into account the iron loss, is compared with the simple id=0 – control. The machine currents and losses during the drive cycle are calculated and compared with each other.