36 resultados para MECHANICAL INFLAMMATORY HYPERNOCICEPTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-metallic implants made of bioresorbable or biostable synthetic polymers are attractive options in many surgical procedures, ranging from bioresorbable suture anchors of arthroscopic surgery to reconstructive skull implants made of biostable fiber-reinforced composites. Among other benefits, non-metallic implants produce less interference in imaging. Bioresorbable polymer implants may be true multifunctional, serving as osteoconductive scaffolds and as matrices for simultaneous delivery of bone enhancement agents. As a major advantage for loading conditions, mechanical properties of biostable fiber-reinforced composites can be matched with those of the bone. Unsolved problems of these biomaterials are related to the risk of staphylococcal biofilm infections and to the low osteoconductivity of contemporary bioresorbable composite implants. This thesis was focused on the research and development of a multifunctional implant model with enhanced osteoconductivity and low susceptibility to infection. In addition, the experimental models for assessment, diagnostics and prophylaxis of biomaterial-related infections were established. The first experiment (Study I) established an in vitro method for simultaneous evaluation of calcium phosphate and biofilm formation on bisphenol-Aglycidyldimethacrylate and triethylenglycoldimethacrylate (BisGMA-TEGDMA) thermosets with different content of bioactive glass 45S5. The second experiment (Study II) showed no significant difference in osteointegration of nanostructured and microsized polylactide-co-glycolide/β-tricalcium phosphate (PLGA /β-TCP) composites in a minipig model. The third experiment (Study III) demonstrated that positron emission tomography (PET) imaging with the novel 68Ga labelled 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) CD33 related sialic-acid immunoglobulin like lectins (Siglec-9) tracer was able to detect inflammatory response to S. epidermidis and S. aureus peri-implant infections in an intraosseous polytetrafluoroethylene catheter model. In the fourth experiment (Study IV), BisGMATEGDMA thermosets coated with lactose-modified chitosan (Chitlac) and silver nanoparticles exhibited antibacterial activity against S. aureus and P. aeruginosa strains in an in vitro biofilm model and showed in vivo biocompatibility in a minipig model. In the last experiment (Study V), a selective androgen modulator (SARM) released from a poly(lactide)-co-ε-caprolactone (PLCL) polymer matrix failed to produce a dose-dependent enhancement of peri-implant osteogenesis in a bone marrow ablation model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Decrease in microbial contacts in affluent societies is considered to lie behind the rise in allergic and other chronic inflammatory diseases during the last decades. Indeed, deviations in the intestinal microbiota composition and diversity have been associated with several diseases, such as atopic eczema. However, there is no consensus yet on what would constitute a beneficial or harmful microbiota. The aim of this thesis was to study the microbiota development in healthy infants and to characterize intestinal microbiota signatures associated with disease status and severity in infants with atopic eczema. The methodological aim was to compare and optimize methods for DNA extraction from fecal samples to be used in high-throughput microbiota analyses. It was confirmed that the most critical step in successful microbial DNA extraction from fecal samples is the mechanical cell lysis procedure. Based on this finding, an efficient semi-automated extraction process was developed that can be scaled for use in high-throughput platforms such as phylogenetic microarray used in this series of studies. By analyzing a longitudinal motherchild cohort for 3 years it was observed that the microbiota development is a gradual process, where some bacterial groups reach the degree of adult-type pattern earlier than others. During the breast-feeding period, the microbiota appeared to be relatively simple, while major diversification was found to start during the weaning process. By the age of 3 years, the child’s microbiota composition started to resemble that of an adult, but the bacterial diversity has still not reached the full diversity, indicating that the microbiota maturation extends beyond this age. In addition, at three years of age, the child’s microbiota was more similar to mother’s microbiota than to microbiota of nonrelated women.In infants with atopic eczema, a high total microbiota diversity and abundance of butyrate-producing bacteria was found to correlate with mild symptoms at 6 months. At 18 months, infants with mild eczema had significantly higher microbiota diversity and aberrant microbiota composition when compared to healthy controls at the same age. In conclusion, the comprehensive phylogenetic microarray analysis of early life microbiota shows the synergetic effect of vertical transmission and shared environment on the intestinal microbiota development. By the age of three years, the compositional development of intestinal microbiota is close to adult level, but the microbiota diversification continues beyond this age. In addition, specific microbiota signatures are associated with the existence and severity of atopic eczema and intestinal microbiota seems to have a role in alleviating the symptoms of this disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thesis is dedicated to enhancement and development of a Mechanism in Company X in order to increase its key parameters and approve its workability. Current Mechanism model is described in details. The basis of various analysis, models and theories that are reflecting the working process of the Mechanism are included in the thesis. According to these three directions of enhancements are chosen: from mechanical, tribological and conceptual points of view. As the result the list of improvements is presented. The new models of Mechanism are built. The efficiency and lifetime value are obtained in accordance with corresponding estimations. The comparative analysis confirms the necessity of conducted changes. Recommendations for the Company X specialists are represented in the thesis. Proposals for deeper research are also suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments were carried out to determine the properties of the welded joints in 8mm thick high-strength steels produced by quenching and tempering and thermomechanical rolling with accelerated cooling (tensile strength 821–835 MPa). The dependence of the strength, elongation, hardness, impact energy and crack opening displacement on the heat input in the range 1.0–0.7 kJ mm21 was determined. The results show that the dependence of the strength of the welded joints decreases and that of the elongation increases. The heat input has only a slight effect on the impact energy and crack opening displacement in the heat-affected zone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Full contour monolithic zirconia restorations have shown an increased popularity in the dental field over the recent years, owing to its mechanical and acceptable optical properties. However, many features of the restoration are yet to be researched and supported by clinical studies to confirm its place among the other indirect restorative materials This series of in vitro studies aimed at evaluating and comparing the optical and mechanical properties, light cure irradiance, and cement polymerization of multiple monolithic zirconia material at variable thicknesses, environments, treatments, and stabilization. Five different monolithic zirconia materials, four of which were partially stabilized and one fully stabilized were investigated. The optical properties in terms of surface gloss, translucency parameter, and contrast ratio were determined via a reflection spectrophotometer at variable thicknesses, coloring, sintering method, and after immersion in an acidic environment. Light cure irradiance and radiant exposure were quantified through the specimens at variable thicknesses and the degree of conversion of two dual-cure cements was determined via Fourier Transform Infrared spectroscopy. Bi-axial flexural strength was evaluated to compare between the partially and fully stabilized zirconia prepared using different coloring and sintering methods. Surface characterization was performed using a scanning electron microscope and a spinning disk confocal microscope. The surface gloss and translucency of the zirconia investigated were brand and thickness dependent with the translucency values decreasing as the thickness increased. Staining decreased the translucency of the zirconia and enhanced surface gloss as well as the flexural strength of the fully stabilized zirconia but had no effect on partially stabilized zirconia. Immersion in a corrosive acid increased surface gloss and decreased the translucency of some zirconia brands. Zirconia thickness was inversely related to the amount of light irradiance, radiant exposure, and degree of monomer conversion. Type of sintering furnace had no effect on the optical and mechanical properties of zirconia. Monolithic zirconia maybe classified as a semi-translucent material that is well influenced by the thickness, limiting its use in the esthetic zones. Conventional acid-base reaction, autopolymerizing and dual-cure cements are recommended for its cementation. Its desirable mechanical properties give it a high potential as a restoration for posterior teeth. However, close monitoring with controlled clinical studies must be determined before any definite clinical recommendations can be drawn.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Utilization of light and illumination systems in automotive industry for different purposes has been increased significantly in recent years. Volvo as one of the leading companies in manufacturing of luxury cars has found the great capacity in this area. The performance of such an illumination systems is one of the challenges that engineers in this industry are facing with. In this study an effort has been made to design a system to make the iron mark of Volvo being illuminated and the system is being evaluated by optics simulation in software using Ray optics method. At the end, results are assessed and some optimizations are carried out. Different kind of light guides, front side of the iron mark and some possible arrangement for LED also evaluated and different materials tested. The best combination from uniformity, color and amount of luminance aspect selected as a possible solution for this special project which can be used as a base for further studies in Volvo.