37 resultados para Graded thickness layer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of computational fluid dynamics (CFD) and finite element analysis (FEA) has been growing rapidly in the various fields of science and technology. One of the areas of interest is in biomedical engineering. The altered hemodynamics inside the blood vessels plays a key role in the development of the arterial disease called atherosclerosis, which is the major cause of human death worldwide. Atherosclerosis is often treated with the stenting procedure to restore the normal blood flow. A stent is a tubular, flexible structure, usually made of metals, which is driven and expanded in the blocked arteries. Despite the success rate of the stenting procedure, it is often associated with the restenosis (re-narrowing of the artery) process. The presence of non-biological device in the artery causes inflammation or re-growth of atherosclerotic lesions in the treated vessels. Several factors including the design of stents, type of stent expansion, expansion pressure, morphology and composition of vessel wall influence the restenosis process. Therefore, the role of computational studies is crucial in the investigation and optimisation of the factors that influence post-stenting complications. This thesis focuses on the stent-vessel wall interactions followed by the blood flow in the post-stenting stage of stenosed human coronary artery. Hemodynamic and mechanical stresses were analysed in three separate stent-plaque-artery models. Plaque was modeled as a multi-layer (fibrous cap (FC), necrotic core (NC), and fibrosis (F)) and the arterial wall as a single layer domain. CFD/FEA simulations were performed using commercial software packages in several models mimicking the various stages and morphologies of atherosclerosis. The tissue prolapse (TP) of stented vessel wall, the distribution of von Mises stress (VMS) inside various layers of vessel wall, and the wall shear stress (WSS) along the luminal surface of the deformed vessel wall were measured and evaluated. The results revealed the role of the stenosis size, thickness of each layer of atherosclerotic wall, thickness of stent strut, pressure applied for stenosis expansion, and the flow condition in the distribution of stresses. The thicknesses of FC, and NC and the total thickness of plaque are critical in controlling the stresses inside the tissue. A small change in morphology of artery wall can significantly affect the distribution of stresses. In particular, FC is the most sensitive layer to TP and stresses, which could determine plaque’s vulnerability to rupture. The WSS is highly influenced by the deflection of artery, which in turn is dependent on the structural composition of arterial wall layers. Together with the stenosis size, their roles could play a decisive role in controlling the low values of WSS (<0.5 Pa) prone to restenosis. Moreover, the time dependent flow altered the percentage of luminal area with WSS values less than 0.5 Pa at different time instants. The non- Newtonian viscosity model of the blood properties significantly affects the prediction of WSS magnitude. The outcomes of this investigation will help to better understand the roles of the individual layers of atherosclerotic vessels and their risk to provoke restenosis at the post-stenting stage. As a consequence, the implementation of such an approach to assess the post-stented stresses will assist the engineers and clinicians in optimizing the stenting techniques to minimize the occurrence of restenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the feasibility of the floating-gate technology in analog computing platforms in a scaled down general-purpose CMOS technology is considered. When the technology is scaled down the performance of analog circuits tends to get worse because the process parameters are optimized for digital transistors and the scaling involves the reduction of supply voltages. Generally, the challenge in analog circuit design is that all salient design metrics such as power, area, bandwidth and accuracy are interrelated. Furthermore, poor flexibility, i.e. lack of reconfigurability, the reuse of IP etc., can be considered the most severe weakness of analog hardware. On this account, digital calibration schemes are often required for improved performance or yield enhancement, whereas high flexibility/reconfigurability can not be easily achieved. Here, it is discussed whether it is possible to work around these obstacles by using floating-gate transistors (FGTs), and analyze problems associated with the practical implementation. FGT technology is attractive because it is electrically programmable and also features a charge-based built-in non-volatile memory. Apart from being ideal for canceling the circuit non-idealities due to process variations, the FGTs can also be used as computational or adaptive elements in analog circuits. The nominal gate oxide thickness in the deep sub-micron (DSM) processes is too thin to support robust charge retention and consequently the FGT becomes leaky. In principle, non-leaky FGTs can be implemented in a scaled down process without any special masks by using “double”-oxide transistors intended for providing devices that operate with higher supply voltages than general purpose devices. However, in practice the technology scaling poses several challenges which are addressed in this thesis. To provide a sufficiently wide-ranging survey, six prototype chips with varying complexity were implemented in four different DSM process nodes and investigated from this perspective. The focus is on non-leaky FGTs, but the presented autozeroing floating-gate amplifier (AFGA) demonstrates that leaky FGTs may also find a use. The simplest test structures contain only a few transistors, whereas the most complex experimental chip is an implementation of a spiking neural network (SNN) which comprises thousands of active and passive devices. More precisely, it is a fully connected (256 FGT synapses) two-layer spiking neural network (SNN), where the adaptive properties of FGT are taken advantage of. A compact realization of Spike Timing Dependent Plasticity (STDP) within the SNN is one of the key contributions of this thesis. Finally, the considerations in this thesis extend beyond CMOS to emerging nanodevices. To this end, one promising emerging nanoscale circuit element - memristor - is reviewed and its applicability for analog processing is considered. Furthermore, it is discussed how the FGT technology can be used to prototype computation paradigms compatible with these emerging two-terminal nanoscale devices in a mature and widely available CMOS technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atomic Layer Deposition (ALD) is the technology of choice where very thin and highquality films are required. Its advantage is its ability to deposit dense and pinhole-free coatings in a controllable manner. It has already shown promising results in a range of applications, e.g. diffusion barrier coatings for OLED displays, surface passivation layers for solar panels. Spatial Atomic Layer Deposition (SALD) is a concept that allows a dramatic increase in ALD throughput. During the SALD process, the substrate moves between spatially separated zones filled with the respective precursor gases and reagents in such a manner that the exposure sequence replicates the conventional ALD cycle. The present work describes the development of a high-throughput ALD process. Preliminary process studies were made using an SALD reactor designed especially for this purpose. The basic properties of the ALD process were demonstrated using the wellstudied Al2O3 trimethyl aluminium (TMA)+H2O process. It was shown that the SALD reactor is able to deposit uniform films in true ALD mode. The ALD nature of the process was proven by demonstrating self-limiting behaviour and linear film growth. The process behaviour and properties of synthesized films were in good agreement with previous ALD studies. Issues related to anomalous deposition at low temperatures were addressed as well. The quality of the coatings was demonstrated by applying 20 nm of the Al2O3 on to polymer substrate and measuring its moisture barrier properties. The results of tests confirmed the superior properties of the coatings and their suitability for flexible electronics encapsulation. Successful results led to the development of a pilot scale roll-to-roll coating system. It was demonstrated that the system is able to deposit superior quality films with a water transmission rate of 5x10-6 g/m2day at a web speed of 0.25 m/min. That is equivalent to a production rate of 180 m2/day and can be potentially increased by using wider webs. State-of-art film quality, high production rates and repeatable results make SALD the technology of choice for manufacturing ultra-high barrier coatings for flexible electronics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alfa Laval Aalborg Oy designs and manufactures waste heat recovery systems utilizing extended surfaces. The waste heat recovery boiler considered in this thesis is a water-tube boiler where exhaust gas is used as the convective heat transfer medium and water or steam flowing inside the tubes is subject to cross-flow. This thesis aims to contribute to the design of waste heat recovery boiler unit by developing a numerical model of the H-type finned tube bundle currently used by Alfa Laval Aalborg Oy to evaluate the gas-side heat transfer performance. The main objective is to identify weaknesses and potential areas of development in the current H-type finned tube design. In addition, numerical simulations for a total of 15 cases with varying geometric parameters are conducted to investigate the heat transfer and pressure drop performance dependent on H-type fin geometry. The investigated geometric parameters include fin width and height, fin spacing, and fin thickness. Comparison between single and double tube type configuration is also conducted. Based on the simulation results, the local heat transfer and flow behaviour of the H-type finned tube is presented including boundary layer development between the fins, the formation of recirculation zone behind the tubes, and the local variations of flow velocity and temperature within the tube bundle and on the fin surface. Moreover, an evaluation of the effects of various fin parameters on heat transfer and pressure drop performance of H-type finned tube bundle has been provided. It was concluded that from the studied parameters fin spacing and fin width had the most significant effect on tube bundle performance and the effect of fin thickness was the least important. Furthermore, the results suggested that the heat transfer performance would increase due to enhanced turbulence if the current double tube configuration is replaced with single tube configuration, but further investigation and experimental measurements are required in order to validate the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Höyryvoimalaitoksen käyttöönotossa muodostuu kattilaputkien sisäpinnoille niitä korroosiolta suojaava ohut metallioksidikerros. Tämän kerroksen päälle kasvaa kattilan käytön aikana haitallista kerrostumaa paikallisen korroosion tai kattilavedessä olevien epäpuhtauksien kerääntymisen tai kiteytymisen seurauksena. Kerrostuma haittaa lämmönsiirtoa tulipesästä putkiseinämän läpi kattilaveteen. Putkien lämpötilan nousu suunniteltua korkeammaksi kasvattaa putkivaurioiden ja sisäpuolisen korroosion riskiä. Tästä johtuen paksuksi kasvaneet kerrostumat pyritään poistamaan happokäsittelyllä eli peittauksella ennen vaurioiden syntyä. Perinteisesti kerrostumapaksuus on määritetty kattilasta irrotetuista näyteputkista mikroskoopilla. Työn tavoitteena oli tutkia uudenlaisen ultraäänimittauksen teoriaa ja selvittää sen toimivuus höyrystinputkien kerrostumapaksuusmittauksissa. Lisäksi tavoitteena oli tutkia voimalaitoksen höyrystimen sisäpuolisten kerrostumien muodostumista ja niiden vaikutuksia sekä kattilan peittaustarpeen arviointia. Höyrystimen kerrostumien kasvunopeuteen vaikuttavat eniten voimalaitostyyppi, käytetty vesikemia ja kattilaveteen kulkeutuvien epäpuhtauksien määrä. Kasvunopeus vaihtelee laitosten välillä suuresti ja eroaa myös tulipesän eri kohdissa. Kattilaveden epäpuhtauspitoisuus ja kerrostumapaksuus vaikuttavat molemmat korroosiovaurioiden todennäköisyyteen. Peittauspaksuuden ohjearvoissa tulisi huomioida kattilan käyttöpaine, kattilatyyppi ja riski kattilaveden laadun heikkenemiselle. Putkinäytteistä ja laitoksilla suoritettujen mittauksien perusteella uusi ultraäänitekniikka tuottaa luotettavia tuloksia tavanomaisten kerrostumien mittauksessa. Vain yhdellä laitoksella esiintyi irtonaisen sakan kaltaista kerrostumaa, jota mittaus ei kyennyt havaitsemaan. Mittaustulokset kerrostumista tulipesän eri osissa antavat hyvän perustan peittaustarpeen arviointiin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Membraani on ohut kalvo, jossa on pieniä nanomittakaavan reikiä, jotka erottavat partikkelit ja liuenneet yhdisteet liuoksesta. Membraanisuodatuksen käyttö on lisääntynyt merkittävästi vedenpuhdistuksessa, johtuen lisääntyneestä puhtaan veden tarpeesta ja tiukentuneista ympäristövaatimuksista. Tässä työssä esitellään reaaliaikaisia mittausmenetelmiä membraanin likaantumisen seurantaan. Esiteltyjä menetelmiä ovat suora havainnointi pinnan läpi, lasertriangulometria, varjoanalyysi, taittokykymittaus, kuvakatkaisu-menetelmä, partikkelin nopeusmääritys, radioisotooppinen merkintä ja ydinmagneettinen resonanssispektrometria. Mittausmenetelmien avulla likakerroksen paksuutta ja sen leviämistä on mahdollista seurata reaaliaikaisesti. Mittausmenetelmien soveltuvuus olemassa oleviin prosesseihin on vielä epävarmaa. Suurin osa menetelmistä on rajoittunut tiettyyn membraanin materiaaliin, tietynlaiseen membraanisuodatusprosessin rakenteeseen tai tiettyihin olosuhteisiin. Vallitsevien prosessiolosuhteiden lisäksi mittausanturin tulisi kestää myös puhdistusolosuhteet. Lisätutkimuksia tarvitaan, jotta voidaan löytää toimiva laitekokonaisuus tarvittavan tiedon tuottamiseen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this thesis was to examine efficiency of freeze crystallization and eutectic freeze crystallization in purification of wastewater by imitating natural freezing. In addition, a mathematic model based on heat transfer to determine ice thickness and ice growth rate was examined. Also, the amount of sodium sulfate crystallized at the eutectic point was under investigation. In literature part, advantages and applications of the freeze crystallization are discussed, and possibility to apply it in Northern hemisphere winter weather conditions is under study. Furthermore, main sources of sodium sulfate from Finnish industries are described. The experiments were carried out in modified chest freezer, where a fan was placed in order to obtain laminar air flow inside. Picolog PT-104 data logger was used to monitor temperature changes in the salt-water solution, and constant temperature was maintained in the crystallizer with Lauda RP 850 thermostat. The impurity of formed ice layer was determined by weighing ice samples after experiment and again after 24 hours drying to full dryness in oven. Volume of salt-water solution was also measured after experiment. The highest purity of formed ice layer was obtained with small temperature difference and with long freezing time. On the other hand, the amount of crystallized sodium sulfate was its greatest with long freezing time and higher temperature difference. The results obtained by the mathematic model and empirical results did not differ significantly in most of the experiments. However, the difference increased when salt-water mixture reached its eutectic point, leading to simultaneous ice and salt crystallization. Eutectic point was reached only with the highest salt concentration with one exception. In these cases, calculated values were in many cases greater than the experimental ones. In winter weather conditions freeze crystallization is cost-effective wastewater treatment method and rather simple. Nonetheless, the efficiency and separation rate are strongly depended on ambient temperature and its changes