60 resultados para Dissolution test
Resumo:
Modern sophisticated telecommunication devices require even more and more comprehensive testing to ensure quality. The test case amount to ensure well enough coverage of testing has increased rapidly and this increased demand cannot be fulfilled anymore only by using manual testing. Also new agile development models require execution of all test cases with every iteration. This has lead manufactures to use test automation more than ever to achieve adequate testing coverage and quality. This thesis is separated into three parts. Evolution of cellular networks is presented at the beginning of the first part. Also software testing, test automation and the influence of development model for testing are examined in the first part. The second part describes a process which was used to implement test automation scheme for functional testing of LTE core network MME element. In implementation of the test automation scheme agile development models and Robot Framework test automation tool were used. In the third part two alternative models are presented for integrating this test automation scheme as part of a continuous integration process. As a result, the test automation scheme for functional testing was implemented. Almost all new functional level testing test cases can now be automated with this scheme. In addition, two models for integrating this scheme to be part of a wider continuous integration pipe were introduced. Also shift from usage of a traditional waterfall model to a new agile development based model in testing stated to be successful.
Resumo:
Artikel i konferensrapport.
Resumo:
Svavel förekommer i kol och olja och oxideras vid förbränning till svaveldioxid (SO2). Årligen utsläpps stora mängder svaveldioxid som åstadkommer sura regn, minskning av stratosfäriskt ozon och sjukdomar. Av dessa orsaker är det nödvändigt att minska utsläppen av svaveldioxid. Den teknologi som rör planering av reaktorer och processer för rökgasavsvavling (FGD) har utvecklats kraftigt och idag använder man olika typer av lösningar. De vanligaste alternativen för FGD är våtskrubber- och semitorra skrubbersystem (Spray Dry Scrubbers, SDS) och injektionsprocesser för absorbenter. SDS-processer har studerats bland annat av Ahlbeck [4] och Klingspor [5] och injektionsprocesser av Alvfors [6]. Kalksten, som i huvusak består av kalciumkarbonat, används i rökgasavsvavling på grund av sin förmåga att binda svavel i form av sulfatsalter. Den vanligaste rökgasavsvavlingsmetoden är våtskrubbning, där det sedimentära stenmaterialets upplösningshastighet är en av de faktorer som påverkar resultatet mest. Utvärdering av kalkstensreaktivitet är därför speciellt viktig vid planering och drift av anläggningar för rökgasavsvavling. Målsättningen med detta arbete var att modellera upplösningen av olika typers kalksten för att få en kvantitativ utvärdering av kvaliteten på de analyserade proverna. Därtill testades även karbonatbiprodukter från stålindustrin för att utvärdera möjligheter att använda andra råmaterial. Det transienta förloppet har analyserats, varvid upplösningshastigheten modellerades bl.a. i avseende på tid och pH. Under arbetets gång har antalet empiriska korrelationer minskats till fördel för fysikaliska modeller av diffusiva och konvektiva masstransportfenomen. En målsättning var att skapa en effektiv och snabb metod för att testa olika absorbenter för rökgasavsvavling under transienta förlopp. I arbetet användes PSD-analys, gjordes pH-mätningar och andra utvärderingar av de fysikaliska parametrar som ingår i beräkningarna. On-line mätningar för de icke-stationära variablerna tid och pH ger möjlighet att eliminera osäkerheter. Vissa modeller kan vara komplicerade. En modell för upplösningshastigheten med mer detaljerad utvärdering av parametrar och färre approximationer är därför nödvändig då man vill utvärdera reaktionshastigheten för fasta partiklar i sur miljö. Arbetet utfördes under fyra år och fem peer review-artiklar ingår i avhandlingen.
Resumo:
In this thesis, the components important for testing work and organisational test process are identified and analysed. This work focuses on the testing activities in reallife software organisations, identifying the important test process components, observing testing work in practice, and analysing how the organisational test process could be developed. Software professionals from 14 different software organisations were interviewed to collect data on organisational test process and testing‐related factors. Moreover, additional data on organisational aspects was collected with a survey conducted on 31 organisations. This data was further analysed with the Grounded Theory method to identify the important test process components, and to observe how real‐life test organisations develop their testing activities. The results indicate that the test management at the project level is an important factor; the organisations do have sufficient test resources available, but they are not necessarily applied efficiently. In addition, organisations in general are reactive; they develop their process mainly to correct problems, not to enhance their efficiency or output quality. The results of this study allows organisations to have a better understanding of the test processes, and develop towards better practices and a culture of preventing problems, not reacting to them.
Resumo:
This paper presents the design for a graphical parameter editor for Testing and Test Control Notation 3 (TTCN-3) test suites. This work was done in the context of OpenTTCN IDE, a TTCN-3 development environment built on top of the Eclipse platform. The design presented relies on an additional parameter editing tab added to the launch configurations for test campaigns. This parameter editing tab shows the list of editable parameters and allows opening editing components for the different parameters. Each TTCN-3 primitive type will have a specific editing component providing tools to ease modification of values of that type.
Resumo:
CHARGE syndrome, Sotos syndrome and 3p deletion syndrome are examples of rare inherited syndromes that have been recognized for decades but for which the molecular diagnostics only have been made possible by recent advances in genomic research. Despite these advances, development of diagnostic tests for rare syndromes has been hindered by diagnostic laboratories having limited funds for test development, and their prioritization of tests for which a (relatively) high demand can be expected. In this study, the molecular diagnostic tests for CHARGE syndrome and Sotos syndrome were developed, resulting in their successful translation into routine diagnostic testing in the laboratory of Medical Genetics (UTUlab). In the CHARGE syndrome group, mutation was identified in 40.5% of the patients and in the Sotos syndrome group, in 34%, reflecting the use of the tests in routine diagnostics in differential diagnostics. In CHARGE syndrome, the low prevalence of structural aberrations was also confirmed. In 3p deletion syndrome, it was shown that small terminal deletions are not causative for the syndrome, and that testing with arraybased analysis provides a reliable estimate of the deletion size but benign copy number variants complicate result interpretation. During the development of the tests, it was discovered that finding an optimal molecular diagnostic strategy for a given syndrome is always a compromise between the sensitivity, specificity and feasibility of applying a new method. In addition, the clinical utility of the test should be considered prior to test development: sometimes a test performing well in a laboratory has limited utility for the patient, whereas a test performing poorly in the laboratory may have a great impact on the patient and their family. At present, the development of next generation sequencing methods is changing the concept of molecular diagnostics of rare diseases from single tests towards whole-genome analysis.
Resumo:
The Repair of segmental defects in load-bearing long bones is a challenging task because of the diversity of the load affecting the area; axial, bending, shearing and torsional forces all come together to test the stability/integrity of the bone. The natural biomechanical requirements for bone restorative materials include strength to withstand heavy loads, and adaptivity to conform into a biological environment without disturbing or damaging it. Fiber-reinforced composite (FRC) materials have shown promise, as metals and ceramics have been too rigid, and polymers alone are lacking in strength which is needed for restoration. The versatility of the fiber-reinforced composites also allows tailoring of the composite to meet the multitude of bone properties in the skeleton. The attachment and incorporation of a bone substitute to bone has been advanced by different surface modification methods. Most often this is achieved by the creation of surface texture, which allows bone growth, onto the substitute, creating a mechanical interlocking. Another method is to alter the chemical properties of the surface to create bonding with the bone – for example with a hydroxyapatite (HA) or a bioactive glass (BG) coating. A novel fiber-reinforced composite implant material with a porous surface was developed for bone substitution purposes in load-bearing applications. The material’s biomechanical properties were tailored with unidirectional fiber reinforcement to match the strength of cortical bone. To advance bone growth onto the material, an optimal surface porosity was created by a dissolution process, and an addition of bioactive glass to the material was explored. The effects of dissolution and orientation of the fiber reinforcement were also evaluated for bone-bonding purposes. The Biological response to the implant material was evaluated in a cell culture study to assure the safety of the materials combined. To test the material’s properties in a clinical setting, an animal model was used. A critical-size bone defect in a rabbit’s tibia was used to test the material in a load-bearing application, with short- and long-term follow-up, and a histological evaluation of the incorporation to the host bone. The biomechanical results of the study showed that the material is durable and the tailoring of the properties can be reproduced reliably. The Biological response - ex vivo - to the created surface structure favours the attachment and growth of bone cells, with the additional benefit of bioactive glass appearing on the surface. No toxic reactions to possible agents leaching from the material could be detected in the cell culture study when compared to a nontoxic control material. The mechanical interlocking was enhanced - as expected - with the porosity, whereas the reinforcing fibers protruding from the surface of the implant gave additional strength when tested in a bone-bonding model. Animal experiments verified that the material is capable of withstanding load-bearing conditions in prolonged use without breaking of the material or creating stress shielding effects to the host bone. A Histological examination verified the enhanced incorporation to host bone with an abundance of bone growth onto and over the material. This was achieved with minimal tissue reactions to a foreign body. An FRC implant with surface porosity displays potential in the field of reconstructive surgery, especially regarding large bone defects with high demands on strength and shape retention in load-bearing areas or flat bones such as facial / cranial bones. The benefits of modifying the strength of the material and adjusting the surface properties with fiber reinforcement and bone-bonding additives to meet the requirements of different bone qualities are still to be fully discovered.
Resumo:
The dewatering of iron ore concentrates requires large capacity in addition to producing a cake with low moisture content. Such large processes are commonly energy intensive and means to lower the specific energy consumption are needed. Ceramic capillary action disc filters incorporate a novel filter medium enabling the harnessing of capillary action, which results in decreased energy consumption in comparison to traditional filtration technologies. As another benefit, the filter medium is mechanically and chemically more durable than, for example, filter cloths and can, thus, withstand harsh operating conditions and possible regeneration better than other types of filter media. In iron ore dewatering, the regeneration of the filter medium is done through a combination of several techniques: (1) backwashing, (2) ultrasonic cleaning, and (3) acid regeneration. Although it is commonly acknowledged that the filter medium is affected by slurry particles and extraneous compounds, published research, especially in the field of dewatering of mineral concentrates, is scarce. Whereas the regenerative effect of backwashing and ultrasound are more or less mechanical, regeneration with acids is based on chemistry. The chemistry behind the acid regeneration is, naturally, dissolution. The dissolution of iron oxide particles has been extensively studied over several decades but those studies may not necessarily be directly applicable in the regeneration of the filter medium which has undergone interactions with the slurry components. The aim of this thesis was to investigate if free particle dissolution indeed correlates with the regeneration of the filter medium. For this purpose, both free particle dissolution and dissolution of surface adhered particles were studied. The focus was on acidic dissolution of iron oxide particles and on the study of the ceramic filter medium used in the dewatering of iron ore concentrates. The free particle dissolution experiments show that the solubility of synthetic fine grained iron oxide particles in oxalic acid could be explained through linear models accounting for the effects of temperature and acid concentration, whereas the dissolution of a natural magnetite is not so easily explained by such models. In addition, the kinetic experiments performed both support and contradict the work of previous authors: the suitable kinetic model here supports previous research suggesting solid state reduction to be the reaction mechanism of hematite dissolution but the formation of a stable iron oxalate is not supported by the results of this research. Several other dissolution mechanisms have also been suggested for iron oxide dissolution in oxalic acid, indicating that the details of oxalate promoted reductive dissolution are not yet agreed and, in this respect, this research offers added value to the community. The results of the regeneration experiments with the ceramic filter media show that oxalic acid is highly effective in removing iron oxide particles from the surface of the filter medium. The dissolution of those particles did not, however, exhibit the expected behaviour, i.e. complete dissolution. The results of this thesis show that although the regeneration of the ceramic filter medium with acids incorporates the dissolution of slurry particles from the surface of the filter medium, the regeneration cannot be assessed purely based upon free particle dissolution. A steady state, dependent on temperature and on the acid concentration, was observed in the dissolution of particles from the surface even though the limit of solubility of free iron oxide particles had not been reached. Both the regeneration capacity and efficiency, with regards to the removal of iron oxide particles, was found to be temperature dependent, but was not affected by the acid concentration. This observation further suggests that the removal of the surface adhered particles does not follow the dissolution of free particles, which do exhibit a dependency on the acid concentration. In addition, changes in the permeability and in the pore structure of the filter medium were still observed after the bulk concentration of dissolved iron had reached a steady state. Consequently, the regeneration of the filter medium continued after the dissolution of particles from the surface had ceased. This observation suggests that internal changes take place at the final stages of regeneration. The regeneration process could, in theory, be divided into two, possibly overlapping, stages: (1) dissolution of surface-adhered particles, and (2) dissolution of extraneous compounds from within the pore structure. In addition to the fundamental knowledge generated during this thesis, tools to assess the effects of parameters on the regeneration of the ceramic filter medium are needed. It has become clear that the same tools used to estimate the dissolution of free particles cannot be used to estimate the regeneration of a filter medium unless only a robust characterisation of the order of regeneration efficiency is needed.
Resumo:
kuv., 8 x 15 cm
Resumo:
kuv., 10 x 15 cm
Resumo:
kuv., 10 x 15 cm
Resumo:
kuv., 8 x 15 cm