26 resultados para wide angle scanning phased array
Resumo:
The main idea of this diploma work is to study electric field distribution on the micro level. For this purpose a silicon edgeless detector was chosen as the object of investigation and scanning electron microscope as an investigation tool. Silicon edgeless detector is an important part of installation for studying proton-proton interactions in TOTEM experiment at Large Hadron Collider. For measurement of electric field distribution inside scanning electron microscope a voltage contrast method was applied.
Resumo:
In the theory part the membrane emulsification was studied. Emulsions are used in many industrial areas. Traditionally emulsions are prepared by using high shear in rotor-stator systems or in high pressure homogenizer systems. In membrane emulsification two immiscible liquids are mixed by pressuring one liquid through the membrane into the other liquid. With this technique energy could be saved, more homogeneous droplets could be formed and the amount of surfactant could be decreased. Ziegler-Natta and single-site catalysts are used in olefin polymerization processes. Nowadays, these catalysts are prepared according to traditional mixing emulsification. More homogeneous catalyst particles that have narrower particle size distribution might be prepared with membrane emulsification. The aim of the experimental part was to examine the possibility to prepare single site polypropylene catalyst using membrane emulsification technique. Different membrane materials and solidification techniques of the emulsion were examined. Also the toluene-PFC phase diagram was successfully measured during this thesis work. This phase diagram was used for process optimization. The polytetrafluoroethylene membranes had the largest contact angles with toluene and also the biggest difference between the contact angles measured with PFC and toluene. Despite of the contact angle measurement results no significant difference was noticed between particles prepared using PTFE membrane or metal sinter. The particle size distributions of catalyst prepared in these tests were quite wide. This would probably be fixed by using a membrane with a more homogeneous pore size distribution. It is also possible that the solidification rate has an effect on the particle sizes and particle morphology. When polymeric membranes are compared PTFE is probably still the best material for the process as it had the best chemical durability.
Resumo:
Polymeric materials have been used in dental applications for decades. Adhesion of polymeric materials to each other and to the tooth substrate is essential to their successful use. The aim of this series of studies was two-folded. First, to improve adhesion of poly(paraphenylene) based rigid rod polymer (RRP) to other dental polymers, and secondly, to evaluate the usability of a new dentin primer system based on RRP fillers. Poly(paraphenylene) based RRP would be a tempting material for dental applications because of its good mechanical properties. To be used in dental applications, reliable adhesion between RRP and other dental polymers is required. In this series of studies, the adhesion of RRP to denture base polymer and the mechanical properties of RRP-denture base polymer-material combination were evaluated. Also adhesion of BisGMA-TEGDMA-resin to RRP was determined. Different surface treatments were tested to improve the adhesion of BisGMA-TEGDMA-resin to RRP. Results were based on three-point bending testing, Vickers surface hardness test and scanning electron microscope analysis (SEM), which showed that no reliable adhesion between RRP and denture base polymer was formed. Addition of RRP filler to denture base polymer increased surface hardness and flexural modulus but flexural strength decreased. Results from the shear bond strength test and SEM revealed that adhesion between resin and RRP was possible to improve by surface treatment with dichloromethane (DCM) based primer and a new kind of adhesive surface can be designed. The current dentin bonding agents have good immediate bond strength, but in long term the bond strength may decrease due to the detrimental effect of water and perhaps by matrix metalloproteinases. This leads to problems in longevity of restorations. Current bonding agents use organic monomers. In this series of studies, RRP filled dentin primer was tested in order to decrease the water sorption of the monomer system of the primers. The properties of new dentin primer system were evaluated in vitro by comparing it to commercial etch and rinse adhesive system. The results from the contact angle measurements and SEM showed that experimental primer with RRP reinforcement provided similar resin infiltration to dentin collagen and formed the resin-dentin interface as the control primer. Microtensile bond strength test and SEM revealed that in short term water storing, RRP increased bond strength and primer with BMEP-monomer (bis[2-(methacryloyloxy)-ethyl]phosphate) and high solvent concentration provided comparable bonding properties to the commercial control primers. In long term water storing, the high solvent-monomer concentration of the experimental primers decreased bond strength. However, in low solvent-monomer concentration groups, the long-term water storing did not decrease the bond strength despite the existence of hydrophilic monomers which were used in the system. These studies demonstrated that new dentin primer system reached the mechanical properties of current traditional etch and rinse adhesive system in short time water storing. Improved properties can be achieved by further modifications of the monomer system. Studies of the adhesion of RRP to other polymers suggest that adhesion between RRP and other dental polymers is possible to obtain by certain surface treatments.
Resumo:
Since the introduction of automatic orbital welding in pipeline application in 1961, significant improvements have been obtained in orbital pipe welding systems. Requirement of more productive welding systems for pipeline application forces manufacturers to innovate new advanced systems and welding processes for orbital welding method. Various methods have been used to make welding process adaptive, such as visual sensing, passive visual sensing, real-time intelligent control, scan welding technique, multi laser vision sensor, thermal scanning, adaptive image processing, neural network model, machine vision, and optical sensing. Numerous studies are reviewed and discussed in this Master’s thesis and based on a wide range of experiments which already have been accomplished by different researches the vision sensor are reported to be the best choice for adaptive orbital pipe welding system. Also, in this study the most welding processes as well as the most pipe variations welded by orbital welding systems mainly for oil and gas pipeline applications are explained. The welding results show that Gas Metal Arc Welding (GMAW) and its variants like Surface Tension Transfer (STT) and modified short circuit are the most preferred processes in the welding of root pass and can be replaced to the Gas Tungsten Arc Welding (GTAW) in many applications. Furthermore, dual-tandem gas metal arc welding technique is currently considered the most efficient method in the welding of fill pass. Orbital GTAW process mostly is applied for applications ranging from single run welding of thin walled stainless tubes to multi run welding of thick walled pipes. Flux cored arc welding process is faster process with higher deposition rate and recently this process is getting more popular in pipe welding applications. Also, combination of gas metal arc welding and Nd:YAG laser has shown acceptable results in girth welding of land pipelines for oil and gas industry. This Master’s thesis can be implemented as a guideline in welding of pipes and tubes to achieve higher quality and efficiency. Also, this research can be used as a base material for future investigations to supplement present finding.
Resumo:
Our understanding of the pathogenesis of organ‐specific autoinflammation has been restricted by limited access to the target organs. Peripheral blood, however, as a preferred transportation route for immune cells, provides a window to assess the entire immune system throughout the body. Transcriptional profiling with RNA stabilizing blood collection tubes reflects in vivo expression profiles at the time the blood is drawn, allowing detection of the disease activity in different samples or within the same sample over time. The main objective of this Ph.D. study was to apply gene‐expression microarrays in the characterization of peripheral blood transcriptional profiles in patients with autoimmune diseases. To achieve this goal a custom cDNA microarray targeted for gene‐expression profiling of human immune system was designed and produced. Sample collection and preparation was then optimized to allow gene‐expression profiling from whole‐blood samples. To overcome challenges resulting from minute amounts of sample material, RNA amplification was successfully applied to study pregnancy related immunosuppression in patients with multiple sclerosis (MS). Furthermore, similar sample preparation was applied to characterize longitudinal genome‐wide expression profiles in children with type 1 diabetes (T1D) associated autoantibodies and eventually clinical T1D. Blood transcriptome analyses, using both the ImmunoChip cDNA microarray with targeted probe selection and genome‐wide Affymetrix U133 Plus 2.0 oligonucleotide array, enabled monitoring of autoimmune activity. Novel disease related genes and general autoimmune signatures were identified. Notably, down‐regulation of the HLA class Ib molecules in peripheral blood was associated with disease activity in both MS and T1D. Taken together, these studies demonstrate the potential of peripheral blood transcriptional profiling in biomedical research and diagnostics. Imbalances in peripheral blood transcriptional activity may reveal dynamic changes that are relevant for the disease but might be completely missed in conventional cross‐sectional studies.
Resumo:
The main focus of this thesis is to define the field weakening point of permanent magnet synchronous machine with embedded magnets in traction applications. Along with the thesis a modelling program is made to help the designer to define the field weakening point in practical applications. The thesis utilizes the equations based on the current angle. These equations can be derived from the vector diagram of permanent magnet synchronous machine. The design parameters of the machine are: The maximum rotational speed, saliency ratio, maximum induced voltage and characteristic current. The main result of the thesis is finding out the rated rotational speed, from which the field weakening starts. The action of the machine is estimated at a wide speed range and the changes of machine parameters are examined.
Resumo:
The offset printing process is complex and involves the meeting of two essentially complex materials, printing ink and paper, upon which the final product is formed. It can therefore be expected that a multitude of chemical and physical interactions and mechanisms take place at the ink-paper interface. Interactions between ink and paper are of interest to both the papermakers and ink producers, as they wish to achieve better quality in the final product. The objective of this work is to clarify the combined influence of paper coating structure, printing ink and fountain solution on ink setting and the problems related to ink setting. A further aim is to identify the mechanisms that influence ink setting problems, and to be able to counteract them by changing properties of the coating layer or by changing the properties of the ink. The work carried out for this thesis included use of many techniques ranging from standard paper and printability tests to advanced optical techniques for detection of ink filaments during ink levelling. Modern imaging methods were applied for assessment of ink filament remain sizes and distribution of ink components inside pigment coating layers. Gravimetric filtration method and assessment of print rub using Ink-Surface-Interaction-Tester (ISIT) were utilized to study the influence of ink properties on ink setting. The chemical interactions were observed with the help of modified thin layer chromatography and contact angle measurements using both conventional and high speed imaging. The results of the papers in this thesis link the press operational parameters to filament sizes and show the influence of these parameters to filament size distribution. The relative importance between the press operation parameters was shown to vary. The size distribution of filaments is important in predicting the ink setting behaviour, which was highlighted by the dynamic gloss and ink setting studies. Prediction of ink setting behaviour was also further improved by use of separate permeability factors for different ink types in connection to filtration equations. The roles of ink components were studied in connection to ink absorption and mechanism of print rub. Total solids content and ratio of linseed oil to mineral oil were found to determine the degree of print rub on coated papers. Wax addition improved print rub resistance, but would not decrease print rub as much as lowering the total solids content in the ink. Linseed oil was shown to absorb into pigment coating pores by mechanism of adsorption to pore walls, which highlights the need for sufficient pore surface area for improved chromatographic separation of ink components. These results should help press operators, suppliers of printing presses, papermakers and suppliers to papermakers, to better understand the material and operating conditions of the press as it relates to various print quality issues. Even though paper is in competition with electronic media, high quality printed products are still in demand. The results should provide useful information for this segment of the industry.
Resumo:
Resonance energy transfer (RET) is a non-radiative transfer of the excitation energy from the initially excited luminescent donor to an acceptor. The requirements for the resonance energy transfer are: i) the spectral overlap between the donor emission spectrum and the acceptor absorption spectrum, ii) the close proximity of the donor and the acceptor, and iii) the suitable relative orientations of the donor emission and the acceptor absorption transition dipoles. As a result of the RET process the donor luminescence intensity and the donor lifetime are decreased. If the acceptor is luminescent, a sensitized acceptor emission appears. The rate of RET depends strongly on the donor–acceptor distance (r) and is inversely proportional to r6. The distance dependence of RET is utilized in binding assays. The proximity requirement and the selective detection of the RET-modified emission signal allow homogeneous separation free assays. The term lanthanide-based RET is used when luminescent lanthanide compounds are used as donors. The long luminescence lifetimes, the large Stokes’ shifts and the intense, sharply-spiked emission spectra of the lanthanide donors offer advantages over the conventional organic donor molecules. Both the organic lanthanide chelates and the inorganic up-converting phosphor (UCP) particles have been used as donor labels in the RET based binding assays. In the present work lanthanide luminescence and lanthanide-based resonance energy transfer phenomena were studied. Luminescence lifetime measurements had an essential role in the research. Modular frequency-domain and time-domain luminometers were assembled and used successfully in the lifetime measurements. The frequency-domain luminometer operated in the low frequency domain ( 100 kHz) and utilized a novel dual-phase lock-in detection of the luminescence. One of the studied phenomena was the recently discovered non-overlapping fluorescence resonance energy transfer (nFRET). The studied properties were the distance and temperature dependences of nFRET. The distance dependence was found to deviate from the Förster theory and a clear temperature dependence was observed whereas conventional RET was completely independent of the temperature. Based on the experimental results two thermally activated mechanisms were proposed for the nFRET process. The work with the UCP particles involved the measurement of the luminescence properties of the UCP particles synthesized in our laboratory. The goal of the UCP particle research is to develop UCP donor labels for binding assays. In the present work the effect of the dopant concentrations and the core–shell structure on the total up-conversion luminescence intensity, the red–green emission ratio, and the luminescence lifetime was studied. Also the non-radiative nature of the energy transfer from the UCP particle donors to organic acceptors was demonstrated for the first time in aqueous environment and with a controlled donor–acceptor distance.
Resumo:
This research establishes the primary components, predictors, and consequences of organizational commitment in the military context. Specifically, the research examines commitment to the military service among Finnish conscripts and whether initial affective commitment prior to service predicts later commitment, attitudes, behavior, and performance, and, furthermore, analyzes the changes in commitment and its possible outcomes. The data were collected from records as well as by surveys from 1,387 rank and file soldiers, immediately after they reported for duty, near the end of basic training, and near the end of 6 to 12 months of service. The data covered a wide array of predictor variables, including background items, attitudes toward conscription, mental and physical health, sociability, training quality, and leadership. Moreover, the archival data included such items as rank, criminal record, performance ratings, and the number of medical examines and exemptions. The measures were further refined based on the results of factor analysis and reliability tests. The results indicated that initial commitment significantly corresponded with expected adjustment, intentions to stay in the military, and acceptance of authority. Moreover, initial commitment moderately related to personal growth, perceived performance, and the number of effective service days at the end of service. During basic training, affective commitment was mostly influenced by challenging training, adjustment experiences, regimentation, and unit climate. At the end of service, committed soldiers demonstrated more personal growth and development in service, had higher-level expected performance, and less malingering during their service. Additionally, they had significantly more positive attitudes toward national defense. The results suggest that affective commitment requires adequate personal adjustment, experiences of personal growth and development, and satisfaction with unit dynamics and training. This research contributes to the theoretical discussion on organizational commitment and the will to defend the nation and advances developing models to support and manage conscript training, education, leadership, and personnel policy. This is achieved by determining the main factors and variables, including their relative strength, that affect commitment to the military service. These findings may also facilitate in designing programs aimed at reducing unwanted discharges and inadequate performance. In particular, these results provide tools for improving conscripts’ overall attachment to and identification with the military service.
Resumo:
The main goal of the present Master’s Thesis project was to create a field-programmable gate array (FPGA) based system for the control of single-electron transistors or other cryoelectronic devices. The FPGA and similar technologies are studied in the present work. The fixed and programmable logic are compared with each other. The main features and limitations of the hardware used in the project are investigated. The hardware and software connections of the device to the computer are shown in detail. The software development techniques for FPGA-based design are described. The steps of design for programmable logic are considered. Furthermore, the results of filters implemented in the software are illustrated.