40 resultados para hydraulic pump


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis gives an overview of the validation process for thermal hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. The cases presented are not exhaustive, but they give a good overview of the work performed by the personnel of Lappeenranta University of Technology (LUT). Large part of the work has been performed in co-operation with the CATHARE-team in Grenoble, France. The design of a Russian type pressurized water reactor, VVER, differs from that of a Western-type PWR. Most of thermal-hydraulic system codes are validated only for the Western-type PWRs. Thus, the codes should be assessed and validated also for VVER design in order to establish any weaknesses in the models. This information is needed before codes can be used for the safety analysis. Theresults of the assessment and validation calculations presented here show that the CATHARE code can be used also for the thermal-hydraulic safety studies for VVER type plants. However, some areas have been indicated which need to be reassessed after further experimental data become available. These areas are mostly connected to the horizontal stem generators, like condensation and phase separation in primary side tubes. The work presented in this thesis covers a large numberof the phenomena included in the CSNI code validation matrices for small and intermediate leaks and for transients. Also some of the phenomena included in the matrix for large break LOCAs are covered. The matrices for code validation for VVER applications should be used when future experimental programs are planned for code validation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työssä on tutkittu pumpun valintaa integroidussa simulointiympäristössä. Tutkimuksen avulla on tarkoitus kehittää tieto- ja malligallerian (Galleria) infrastuktuuria ja käytössä olevia työvälineitä siihen suuntaan, että ulkoisten valitsinkomponenttien implementoiminen Gallerian tietokantaan olisi lähitulevaisuudessa helppoa ja nopeaa. Prosessi-integraation tieto- ja malligalleria on infrastruktuurimäärittely ja työvälineistö prosessikomponenttien ja osaprosessien simulointiin tarvittavien malli- ja parametritietojen kirjastoimiseksi internetpohjaiseen tietokantaan, josta ne ovat simulointiohjelmien käyttäjien ja muiden prosessisuunnittelijoiden helposti saatavilla. Tutkimuksen kirjallisessa osassa on keskitytty tutkimaan pumpun valinnan etenemistä ja valintaan vaikuttavia tekijöitä prosessisuunnittelijan näkökulmasta. Tutkimuksen soveltavassa osassa luotiin pumpunvalitsin ja sitä testattiiin Galleria- ympäristöä vastaavassa kehitysympäristössä. Pumpunvalitsimen kehittämisessä on käytetty apuna laitevalmistajalta saatua prosessikomponenttitietoa. Pumpunvalitsimen toteutus perustuu pumpun hydrauliseen valintaan ja esimerkkitapauksena käytettiin keskipakopumppua

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä diplomityössä käsitellään pumppujen maailmanlaajuista varaosa-jakelua. Työn pääpaino on varaosien moniportaisen jakeluverkon toimitusketjun logistiikassa. Asiakaspalvelussa varaosien nopea saatavuus on ratkaisevassa asemassa, jotta asiakkaiden tehtaiden käynnissäpito voidaan turvata. Työn tavoitteena oli kehittää Ahlström Pumpuille uusi globaali toimintamalli varaosien jakeluun. Tämä uusi varaosien jakelumalli on kehitetty pääasiassa sopimusasiakkaille, jotka ovat halukkaita ulkoistamaan varaosatoimintonsa. Mallia sovelletaan käytäntöön varaosien jakelussa ensiksi Suomessa ja Ruotsissa. Myöhemmin on tarkoitus kopioida mallia myös muualle. Malli on pyritty rakentamaan siten, että siihen voidaan helposti liittää muita Ahlström Pumppujen tarjoamia palveluita. Työssä koottu materiaali perustuu pääasiassa haastatteluihin, palavereihin, erilaisiin sisäisiin raportteihin, kirjallisuuteen ja itsenäiseen selvitystyöhön. Työssä on myös tutustuttu kolmen eri yrityksen after-sales- ja varaosatoimintaan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työn tavoitteena oli laatia euron käyttöönottosuunnitelma. Ensin selvitettiin euron syntyvaiheet ja yhteisen valuutan käsittelysäännöt. Sen jälkeen käydään läpi eräs käyttökelpoinen suunnitelma euron käyttöönottamiseksi, johon kuuluu euron käyttöönoton and speed up the implementation of external selection components. Model and Parametrisation Gallery for Process Integration is specification of an infrastructure and a set of tools which are built for storing process component and model library data into an internet based database from where it can be easily used by simulator users and other process designers. This work consists of two parts. In the literature survey pump selection and the factors that affects selection particularly on process designers point of view are studied. In the applied part a pump selector was created and tested in the test environment which is comparable to Gallery environment. This was done to ease the deployment of the selector to the actual working environment. Process component data of a manufacturer was used on the development of the pump selector. The execution of the selector is based on the hydraulic selection of pumps. Centrifugal pump was used as an example case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several possible methods of increasing the efficiency and power of hydro power plants by improving the flow passages are investigated in this stydy. The theoretical background of diffuser design and its application to the optimisation of hydraulic turbine draft tubes is presented in the first part of this study. Several draft tube modernisation projects that have been carried out recently are discussed. Also, a method of increasing the efficiency of the draft tube by injecting a high velocity jet into the boundary layer is presented. Methods of increasing the head of a hydro power plant by using an ejector or a jet pump are discussed in the second part of this work. The theoretical principles of various ejector and jet pump types are presented and four different methods of calculating them are examined in more detail. A self-made computer code is used to calculate the gain in the head for two example power plants. Suitable ejector installations for the example plants are also discussed. The efficiency of the ejector power was found to be in the range 6 - 15 % for conventional head increasers, and 30 % for the jet pump at its optimum operating point. In practice, it is impossible to install an optimised jet pump with a 30 % efficiency into the draft tube as this would considerabely reduce the efficiency of the draft tube at normal operating conditions. This demonstrates, however, the potential for improvement which lies in conventional head increaser technology. This study is based on previous publications and on published test results. No actual laboratory measurements were made for this study. Certain aspects of modelling the flow in the draft tube using computational fluid dynamics are discussed in the final part of this work. The draft tube inlet velocity field is a vital boundary condition for such a calculation. Several previously measured velocity fields that have successfully been utilised in such flow calculations are presented herein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis analyses the calculation of FanSave and PumpSave energy saving tools calculation. With these programs energy consumption of variable speed drive control for fans and pumps can be compared to other control methods. With FanSave centrifugal and axial fans can be examined and PumpSave deals with centrifugal pumps. By means of these programs also suitable frequency converter can be chosen from the ABB collection. Programs need as initial values information about the appliances like amount of flow and efficiencies. Operation time is important factor when calculating the annual energy consumption and information about it are the length and profile. Basic theory related to fans and pumps is introduced without more precise instructions for dimensioning. FanSave and PumpSave contain various methods for flow control. These control methods are introduced in the thesis based on their operational principles and suitability. Also squirrel cage motor and frequency converter are introduced because of their close involvement to fans and pumps. Second part of the thesis contains comparison between results of FanSave’s and PumpSave’s calculation and performance curve based calculation. Also laboratory tests were made with centrifugal and axial fan and also with centrifugal pump. With the results from this thesis the calculation of these programs can be adjusted to be more accurate and also some new features can be added.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study is to obtain a mathematical description for an alternative variant of controlling a hydraulic circuit with an electrical drive. The electrical and hydraulic systems are described by basic mathematical equations. The flexibilities of the load and boom is modeled with assumed mode method. The model is achieved and proven with simulations. The controller is constructed and proven to decrease oscillations and improve the dynamic response of the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The general task of clamping devise is to connect the parts to the machining centers so that the work piece could be fixed on its position during the whole machining process. Additionally, the work piece should be clamped easily and rapidly by the machine users. The purpose of this Master’s thesis project was to develop a product design and find out the dimensioning of a hydraulic vise system for Astex Engineering OY, which was taking care of the general principles of product design and development during the design process. Throughout the process, the needs of manufacturing and assembling were taken into consideration for the machinability and minimization of the cost of manufacturing. The most critical component of the clamping devise was modeled by FEM for the issue of strength requirements. This 3D model was created with Solidworks and FEM-analysis was done with Cosmos software. As the result of this design work, a prototype of the hydraulic vise was manufactured for Astex Engineering OY and the practical test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the current economy situation companies try to reduce their expenses. One of the solutions is to improve the energy efficiency of the processes. It is known that the energy consumption of pumping applications range from 20 up to 50% of the energy usage in the certain industrial plants operations. Some studies have shown that 30% to 50% of energy consumed by pump systems could be saved by changing the pump or the flow control method. The aim of this thesis is to create a mobile measurement system that can calculate a working point position of a pump drive. This information can be used to determine the efficiency of the pump drive operation and to develop a solution to bring pump’s efficiency to a maximum possible value. This can allow a great reduction in the pump drive’s life cycle cost. In the first part of the thesis, a brief introduction in the details of pump drive operation is given. Methods that can be used in the project are presented. Later, the review of available platforms for the project implementation is given. In the second part of the thesis, components of the project are presented. Detailed description for each created component is given. Finally, results of laboratory tests are presented. Acquired results are compared and analyzed. In addition, the operation of created system is analyzed and suggestions for the future development are given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Centrifugal pumps are widely used in industrial and municipal applications, and they are an important end-use application of electric energy. However, in many cases centrifugal pumps operate with a significantly lower energy efficiency than they actually could, which typically has an increasing effect on the pump energy consumption and the resulting energy costs. Typical reasons for this are the incorrect dimensioning of the pumping system components and inefficiency of the applied pump control method. Besides the increase in energy costs, an inefficient operation may increase the risk of a pump failure and thereby the maintenance costs. In the worst case, a pump failure may lead to a process shutdown accruing additional costs. Nowadays, centrifugal pumps are often controlled by adjusting their rotational speed, which affects the resulting flow rate and output pressure of the pumped fluid. Typically, the speed control is realised with a frequency converter that allows the control of the rotational speed of an induction motor. Since a frequency converter can estimate the motor rotational speed and shaft torque without external measurement sensors on the motor shaft, it also allows the development and use of sensorless methods for the estimation of the pump operation. Still today, the monitoring of pump operation is based on additional measurements and visual check-ups, which may not be applicable to determine the energy efficiency of the pump operation. This doctoral thesis concentrates on the methods that allow the use of a frequency converter as a monitoring and analysis device for a centrifugal pump. Firstly, the determination of energy-efficiency- and reliability-based limits for the recommendable operating region of a variable-speed-driven centrifugal pump is discussed with a case study for the laboratory pumping system. Then, three model-based estimation methods for the pump operating location are studied, and their accuracy is determined by laboratory tests. In addition, a novel method to detect the occurrence of cavitation or flow recirculation in a centrifugal pump by a frequency converter is introduced. Its sensitivity compared with known cavitation detection methods is evaluated, and its applicability is verified by laboratory measurements for three different pumps and by using two different frequency converters. The main focus of this thesis is on the radial flow end-suction centrifugal pumps, but the studied methods can also be feasible with mixed and axial flow centrifugal pumps, if allowed by their characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työssä selvitettiin Neste Oil Porvoon jalostamon tuotantolinja 2 jäähdytysvesiverkon tilaa. Jäähdytysvesiverkon hydraulinen malli päivitettiin ja verifioitiin painemittauksin. Mallia tarkennettiin säätöventtiilien mallinnuksen sekä virhelähteiden tarkastelun perusteella havaituin muutoksin. Mallin verifioinnissa havaittiin huomattavia eroja mallin ja mitattujen paineiden välillä. Tämä johti mallin tarkempaan tarkasteluun, sekä virhelähteiden ja niiden vaikutusten selvittämiseen. Putkivarusteiden mallinnusmenetelmiä, sekä mallinnusperiaatteita vertailtiin keskenään. Koska jäähdytysveden kokonaiskierto oli riittämätön, tarkasteltiin kolmea vaihtoehtoa riittävän kiertovesimäärän aikaansaamiseksi. Nykyisten kiertovesipumppujen rinnanoperointi, sekä riittävän suureksi skaalatun pumpun käyttö simuloitiin. Kolmantena tapauksena arvioitiin lämmönvaihdinkohtaisen kuristussuunnitelman vaikutus putkiston painehäviöön, sekä putkistolle sopiva kiertovesipumppu. Vaihtoehdoille laskettiin suuntaa-antavat investointi- ja käyttökustannukset. Tarkastelun perusteella riittävän suureksi skaalattu pumppu todettiin kannattavimmaksi pienen hintaeron, sekä luotettavamman jäähdytysvesikierron käyttövarmuuden vuoksi. Työssä onnistuttiin tuottamaan yleispätevää tietoa suljetun jäähdytysvesiverkon hydrauliseen mallinnukseen vaikuttavista tekijöistä, sekä niiden vaikutuksesta mallin tarkkuuteen. Selvityksen perusteella tarkasteltua mallia saatiin tarkemmaksi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Decreasing bone mass during aging predisposes to fractures and it is estimated that every second woman and one in five men will suffer osteoporotic fractures during their lifetime. Bone is an adaptive tissue undergoing continuous remodeling in response to physical and metabolic stimuli. Bone mass decreases through a net negative balance in the bone remodeling process of bone, in which the new bone incompletely replaces the resorbed bone mass. Bone resorption is carried out by the osteoclasts; the bone mineral is solubilized by acidification and the organic matrix is subsequently degraded by proteases. Several classes of drugs are available for prevention of osteoporotic fractures. They act by different mechanisms to increase bone mass, and some of them act mainly as antiresorptives by inhibition of osteoclast formation or their function. Optimally, a drug should act selectively on a specific process, since other processes affected usually result in adverse effects. The purpose of this study was to evaluate whether the osteoclastic vacuolar adenosine trisphosphatases (V-ATPase), which drives the solubilization of bone mineral, can be selectively inhibited despite its ubiquitous cellular functions. The V-ATPase is a multimeric protein composed of 13 subunits of which six possesses two or more isoforms. Selectivity for the osteoclastic V-ATPase could be provided if it has some structural uniqueness, such as a unique isoform combination. The a3 isoform of the 116kDa subunit is inevitable for bone resorption; however, it is also present in, and mainly limited to, the lysosomes of other cells. No evidence of a structural uniqueness of the osteoclastic V-ATPase compared to the lysosomal V-ATPase was found, although this can not yet be excluded. Thus, an inhibitor selective for the a3 isoform would target the lysosomal V-ATPase as well. However, the results suggest that selectivity for bone resorption over lysosomal function can be obtained by two other mechanisms, suggesting that isoform a3 is a valid target. The first is differential compensation; bone resorption depends on the high level of a3 expression, and is not compensated for by other isoforms, while the lower level of a3 in lysosomes of other cells may be partly compensated for. The second mechanism is because the bone resorption process itself is fundamentally different from lysosomal acidification because of the chemistry of bone dissolution and the anatomy of the resorbing osteoclast. By this mechanism, full inhibition of bone resorption is obtained with more than tenfold lower inhibitor concentration than those needed to fully inhibit lysosomal acidification. The two mechanisms are additive. Based on the results, we suggest that bone resorption can be selectively inhibited if VATPase inhibitors that are sufficiently selective for the a3 isoform over the other isoforms are developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the this research project is to develop a novel force control scheme for the teleoperation of a hydraulically driven manipulator, and to implement an ideal transparent mapping between human and machine interaction, and machine and task environment interaction. This master‘s thesis provides a preparatory study for the present research project. The research is limited into a single degree of freedom hydraulic slider with 6-DOF Phantom haptic device. The key contribution of the thesis is to set up the experimental rig including electromechanical haptic device, hydraulic servo and 6-DOF force sensor. The slider is firstly tested as a position servo by using previously developed intelligent switching control algorithm. Subsequently the teleoperated system is set up and the preliminary experiments are carried out. In addition to development of the single DOF experimental set up, methods such as passivity control in teleoperation are reviewed. The thesis also contains review of modeling of the servo slider in particular reference to the servo valve. Markov Chain Monte Carlo method is utilized in developing the robustness of the model in presence of noise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Approximately a quarter of electrical power consumption in pulp and paper industry is used in different pumping systems. Therefore, improving pumping system efficiency is a considerable way to reduce energy consumption in different processes. Pumping of wood pulp in different consistencies is common in pulp and paper industry. Earlier, centrifugal pumps were used to pump pulp only at low consistencies, but development of MC technology has made it possible to pump medium consistency pulp. Pulp is a non-Newtonian fluid, which flow characteristics are significantly different than what of water. In this thesis is examined the energy efficiency of pumping medium consistency pulp with centrifugal pump. The factors effecting the pumping of MC pulp are presented and through case study is examined the energy efficiency of pumping in practice. With data obtained from the case study are evaluated the effects of pump rotational speed and pulp consistency on energy efficiency. Additionally, losses caused by control valve and validity of affinity laws in pulp pumping are evaluated. The results of this study can be used for demonstrating the energy consumption of MC pumping processes and finding ways to improve energy efficiency in these processes.