35 resultados para acoustic radiation force


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Planar, large area, position sensitive silicon detectors are widely utilized in high energy physics research and in medical, computed tomography (CT). This thesis describes author's research work relating to development of such detector components. The key motivation and objective for the research work has been the development of novel, position sensitive detectors improving the performance of the instruments they are intended for. Silicon strip detectors are the key components of barrel-shaped tracking instruments which are typically the innermost structures of high energy physics experimental stations. Particle colliders such as the former LEP collider or present LHC produce particle collisions and the silicon strip detector based trackers locate the trajectories of particles emanating from such collisions. Medical CT has become a regular part of everyday medical care in all developed countries. CT scanning enables x-ray imaging of all parts of the human body with an outstanding structural resolution and contrast. Brain, chest and abdomen slice images with a resolution of 0.5 mm are possible and latest CT machines are able to image whole human heart between heart beats. The two application areas are presented shortly and the radiation detection properties of planar silicon detectors are discussed. Fabrication methods and preamplifier electronics of the planar detectors are presented. Designs of the developed, large area silicon detectors are presented and measurement results of the key operating parameters are discussed. Static and dynamic performance of the developed silicon strip detectors are shown to be very satisfactory for experimental physics applications. Results relating to the developed, novel CT detector chips are found to be very promising for further development and all key performance goals are met.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis comprises seven peer-reviewed articles and examines systems and applications suitable for increasing Future Force Warrior performance, minimizing collateral damage, improving situational awareness and Common Operational Picture. Based on a literature study, missing functionalities of Future Force Warrior were identified and new ideas, concepts and solutions were created as part of early stages of Systems of Systems creation. These introduced ideas have not yet been implemented or tested in combat and for this reason benefit analyses are excluded. The main results of this thesis include the following: A new networking concept, Wireless Polling Sensor Network, which is a swarm of a few Unmanned Aerial Vehicles forming an ad-hoc network and polling a large number of fixed sensor nodes. The system is more robust in a military environment than traditional Wireless Sensor Networks. A Business Process approach to Service Oriented Architecture in a tactical setting is a concept for scheduling and sharing limited resources. New components to military Service Oriented Architecture have been introduced in the thesis. Other results of the thesis include an investigation of the use of Free Space Optics in tactical communications, a proposal for tracking neutral forces, a system for upgrading simple collaboration tools for command, control and collaboration purposes, a three-level hierarchy of Future Force Warrior, and methods for reducing incidents of fratricide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lanthanum lutetium oxide (LaLuO3) thin films were investigated considering their perspective application for industrial microelectronics. Scanning probe microscopy (SPM) techniques permitted to visualize the surface topography and study the electric properties. This work compared both the material properties (charge behavior for samples of 6 nm and 25 nm width) and the applied SPM modes. Particularly, Kelvin probe force microscopy (KPFM) was applied to characterize local potential difference with high lateral resolution. Measurements showed the difference in morphology, chargeability and charge dissipation time for both samples. The polarity effect was detected for this material for the first time. Lateral spreading of the charged spots indicate the diffusive mechanism to be predominant in charge dissipation. This allowed to estimate the diffusion coefficient and mobility. Using simple electrostatic model it was found that charge is partly leaking into the interface oxide layer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Julkaisumaa : 040 AT AUT Itävalta. - Julkaisu sisältää kaksi DVD:tä ja 13 sivuisen tekstiliitteen, projektin verkkosivusto http://europeanacousticheritage.eu/the-project/

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presentation at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study applied qualitative case study method for solving what kind of benefits salespeople and their customers perceived to gain when sales reps used a specific sales force automation tool, that defined the values and identified segment that best fit to each customer. The data consisting of four interviews was collected using semi-structured individual method and analyzed with thematic analysis technique. The analysis revealed five salespeople perceived benefits and four customer perceived benefits. Salespeople perceived benefits were improvements in customer knowledge, guidance of sales operations, salesperson-customer relationship building, time management and growing performance. Customer perceived benefits were information transmission, improved customer service, customer-salesperson relationship building and development of operations, which of the last was found as a new previously unrecognized customer benefit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis properties and influence of modification techniques of porous silicon were studied by Atomic Force Microscope (AFM). This device permits to visualize the surface topography and to study properties of the samples on atomic scale, which was necessary for recent investigation. Samples of porous silicon were obtained by electrochemical etching. Nickel particles were deposited by two methods: electrochemical deposition and extracting from NiCl2 ethanol solution. Sample growth was conducted in Saint-Petersburg State Electrotechnical University, LETI. Kelvin probe force microscopy (KPFM) and Magnetic force microscopy (MFM) were utilized for detailed information about surface properties of the samples. Measurements showed the difference in morphology correlating with initial growth conditions. Submicron size particles were clearly visible on surfaces of the treated samples. Although their nature was not clarified due to limitations of AFM technique. It is expected that surfaces were covered by nanometer scale Ni particles, which can be verified by implication of RAMAN device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute otitis media (AOM) is the most prevalent bacterial infection among children. Tympanometry and spectral gradient acoustic reflectometry (SG-AR) are adjunctive diagnostic tools to pneumatic otoscopy. The aim was to investigate the diagnostic accuracy and success rates of tympanometry and SG-AR performed by physicians and nurses. The study populations comprised 515 (I-II), 281 (III), and 156 (IV) outpatients (6-35 months). Physicians performed 4246 tympanometric (I) and SG-AR (II) examinations. Nurses performed 1782 (III) and 753 (IV) examinations at symptomatic and asymptomatic visits, respectively. Pneumatic otoscopy by the physician was the diagnostic standard. The accuracy of test results by physicians or nurses (I-IV) and the proportion of visits with accurate exclusive test results from both ears (III-IV) were analyzed. Type B tympanogram and SG-AR level 5 (<49˚) predicted middle ear effusion (MEE). At asymptomatic visits, type A and C1 tympanograms (peak pressure > -200 daPa) and SG-AR level 1 (>95˚) indicated healthy middle ear. Negative predictive values of type A and C1 tympanograms by nurses in excluding AOM at symptomatic and MEE at asymptomatic visits were 94% and 95%, respectively. Nurses obtained type A or C1 tympanogram from both ears at 94/459 (20%) and 81/196 (41%) of symptomatic and asymptomatic visits, respectively. SG-AR level 1 was rarely obtained from both ears. Type A and C1 tympanograms were accurate in excluding AOM at symptomatic and MEE at asymptomatic visits. However, nurses obtained these tympanograms from both ears only at one fifth of symptomatic visits and less than half of asymptomatic visits.