24 resultados para Ultrasonic wave reflection


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Type 2 diabetes patients have a 2-4 fold risk of cardiovascular disease (CVD) compared to the general population. In type 2 diabetes, several CVD risk factors have been identified, including obesity, hypertension, hyperglycemia, proteinuria, sedentary lifestyle and dyslipidemia. Although much of the excess CVD risk can be attributed to these risk factors, a significant proportion is still unknown. Aims: To assess in middle-aged type 2 diabetic subjects the joint relations of several conventional and non-conventional CVD risk factors with respect to cardiovascular and total mortality. Subjects and methods: This thesis is part of a large prospective, population based East-West type 2 diabetes study that was launched in 1982-1984. It includes 1,059 middle-aged (45-64 years old) participants. At baseline, a thorough clinical examination and laboratory measurements were performed and an ECG was recorded. The latest follow-up study was performed 18 years later in January 2001 (when the subjects were 63-81 years old). The study endpoints were total mortality and mortality due to CVD, coronary heart disease (CHD) and stroke. Results: Physically more active patients had significantly reduced total, CVD and CHD mortality independent of high-sensitivity C-reactive protein (hs-CRP) levels unless proteinuria was present. Among physically active patients with a hs-CRP level >3 mg/L, the prognosis of CVD mortality was similar to patients with hs-CRP levels ≤3 mg/L. The worst prognosis was among physically inactive patients with hs-CRP levels >3 mg/L. Physically active patients with proteinuria had significantly increased total and CVD mortality by multivariate analyses. After adjustment for confounding factors, patients with proteinuria and a systolic BP <130 mmHg had a significant increase in total and CVD mortality compared to those with a systolic BP between 130 and 160 mmHg. The prognosis was similar in patients with a systolic BP <130 mmHg and ≥160 mmHg. Among patients without proteinuria, a systolic BP <130 mmHg was associated with a non-significant reduction in mortality. A P wave duration ≥114 ms was associated with a 2.5-fold increase in stroke mortality among patients with prevalent CHD or claudication. This finding persisted in multivariable analyses. Among patients with no comorbidities, there was no relationship between P wave duration and stroke mortality. Conclusions: Physical activity reduces total and CVD mortality in patients with type 2 diabetes without proteinuria or with elevated levels of hs-CRP, suggesting that the anti-inflammatory effect of physical activity can counteract increased CVD morbidity and mortality associated with a high CRP level. In patients with proteinuria the protective effect was not, however, present. Among patients with proteinuria, systolic BP <130 mmHg may increase mortality due to CVD. These results demonstrate the importance of early intervention to prevent CVD and to control all-cause mortality among patients with type 2 diabetes. The presence of proteinuria should be taken into account when defining the target systolic BP level for prevention of CVD deaths. A prolongation of the duration of the P wave was associated with increased stroke mortality among high-risk patients with type 2 diabetes. P wave duration is easy to measure and merits further examination to evaluate its importance for estimation of the risk of stroke among patients with type 2 diabetes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

julkaisumaa: 372 IE IRL Irlanti

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrokinetics has emerged as a potential technique for in situ soil remediation and especially unique because of the ability to work in low permeability soil. In electrokinetic remediation, non-polar contaminants like most organic compounds are transported primarily by electroosmosis, thus the process is effective only if the contaminants are soluble in pore fluid. Therefore, enhancement is needed to improve mobility of these hydrophobic compounds, which tend to adsorb strongly to the soil. On the other hand, as a novel and rapidly growing science, the applications of ultrasound in environmental technology hold a promising future. Compared to conventional methods, ultrasonication can bring several benefits such as environmental friendliness (no toxic chemical are used or produced), low cost, and compact instrumentation. It also can be applied onsite. Ultrasonic energy applied into contaminated soils can increase desorption and mobilization of contaminants and porosity and permeability of soil through developing of cavitation. The research investigated the coupling effect of the combination of these two techniques, electrokinetics and ultrasonication, in persistent organic pollutant removal from contaminated low permeability clayey soil (with kaolin as a model medium). The preliminary study checked feasibility of ultrasonic treatment of kaolin highly contaminated by persistent organic pollutants (POPs). The laboratory experiments were conducted in various conditions (moisture, frequency, power, duration time, initial concentration) to examine the effects of these parameters on the treatment process. Experimental results showed that ultrasonication has a potential to remove POPs, although the removal efficiencies were not high with short duration time. The study also suggested intermittent ultrasonication over longer time as an effective means to increase the removal efficiencies. Then, experiments were conducted to compare the performances among electrokinetic process alone and electrokinetic processes combined with surfactant addition and mainly with ultrasonication, in designed cylinders (with filtercloth separating central part and electrolyte parts) and in open pans. Combined electrokinetic and ultrasonic treatment did prove positive coupling effect compared to each single process alone, though the level of enhancement is not very significant. The assistance of ultrasound in electrokinetic remediation can help reduce POPs from clayey soil by improving the mobility of hydrophobic organic compounds and degrading these contaminants through pyrolysis and oxidation. Ultrasonication also sustains higher current and increases electroosmotic flow. Initial contaminant concentration is an essential input parameter that can affect the removal effectiveness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis presents point-contact measurements between superconductors (Nb, Ta, Sn,Al, Zn) and ferromagnets (Co, Fe, Ni) as well as non-magnetic metals (Ag, Au, Cu, Pt).The point contacts were fabricated using the shear method. The differential resistanceof the contacts was measured either in liquid He at 4.2 K or in vacuum in a dilutionrefrigerator at varying temperature down to 0.1 K. The contact properties were investigatedas function of size and temperature. The measured Andreev-reflection spectrawere analysed in the framework of the BTK model – a three parameter model that describescurrent transport across a superconductor - normal conductor interface. Theoriginal BTK model was modified to include the effects of spin polarization or finitelifetime of the Cooper pairs. Our polarization values for the ferromagnets at 4.2 K agree with the literature data, but the analysis was ambiguous because the experimental spectra both with ferromagnets and non-magnets could be described equally well either with spin polarization or finite lifetime effects in the BTK model. With the polarization model the Z parametervaries from almost 0 to 0.8 while the lifetime model produces Z values close to 0.5. Measurements at lower temperatures partly lift this ambiguity because the magnitude of thermal broadening is small enough to separate lifetime broadening from the polarization. The reduced magnitude of the superconducting anomalies for Zn-Fe contacts required an additional modification of the BTK model which was implemented as a scaling factor. Adding this parameter led to reduced polarization values. However, reliable data is difficult to obtain because different parameter sets produce almost identical spectra.