23 resultados para SLOT
Resumo:
Today’s electrical machine technology allows increasing the wind turbine output power by an order of magnitude from the technology that existed only ten years ago. However, it is sometimes argued that high-power direct-drive wind turbine generators will prove to be of limited practical importance because of their relatively large size and weight. The limited space for the generator in a wind turbine application together with the growing use of wind energy pose a challenge for the design engineers who are trying to increase torque without making the generator larger. When it comes to high torque density, the limiting factor in every electrical machine is heat, and if the electrical machine parts exceed their maximum allowable continuous operating temperature, even for a short time, they can suffer permanent damage. Therefore, highly efficient thermal design or cooling methods is needed. One of the promising solutions to enhance heat transfer performances of high-power, low-speed electrical machines is the direct cooling of the windings. This doctoral dissertation proposes a rotor-surface-magnet synchronous generator with a fractional slot nonoverlapping stator winding made of hollow conductors, through which liquid coolant can be passed directly during the application of current in order to increase the convective heat transfer capabilities and reduce the generator mass. This doctoral dissertation focuses on the electromagnetic design of a liquid-cooled direct-drive permanent-magnet synchronous generator (LC DD-PMSG) for a directdrive wind turbine application. The analytical calculation of the magnetic field distribution is carried out with the ambition of fast and accurate predicting of the main dimensions of the machine and especially the thickness of the permanent magnets; the generator electromagnetic parameters as well as the design optimization. The focus is on the generator design with a fractional slot non-overlapping winding placed into open stator slots. This is an a priori selection to guarantee easy manufacturing of the LC winding. A thermal analysis of the LC DD-PMSG based on a lumped parameter thermal model takes place with the ambition of evaluating the generator thermal performance. The thermal model was adapted to take into account the uneven copper loss distribution resulting from the skin effect as well as the effect of temperature on the copper winding resistance and the thermophysical properties of the coolant. The developed lumpedparameter thermal model and the analytical calculation of the magnetic field distribution can both be integrated with the presented algorithm to optimize an LC DD-PMSG design. Based on an instrumented small prototype with liquid-cooled tooth-coils, the following targets have been achieved: experimental determination of the performance of the direct liquid cooling of the stator winding and validating the temperatures predicted by an analytical thermal model; proving the feasibility of manufacturing the liquid-cooled tooth-coil winding; moreover, demonstration of the objectives of the project to potential customers.
Resumo:
Thesis: A liquid-cooled, direct-drive, permanent-magnet, synchronous generator with helical, double-layer, non-overlapping windings formed from a copper conductor with a coaxial internal coolant conduit offers an excellent combination of attributes to reliably provide economic wind power for the coming generation of wind turbines with power ratings between 5 and 20MW. A generator based on the liquid-cooled architecture proposed here will be reliable and cost effective. Its smaller size and mass will reduce build, transport, and installation costs. Summary: Converting wind energy into electricity and transmitting it to an electrical power grid to supply consumers is a relatively new and rapidly developing method of electricity generation. In the most recent decade, the increase in wind energy’s share of overall energy production has been remarkable. Thousands of land-based and offshore wind turbines have been commissioned around the globe, and thousands more are being planned. The technologies have evolved rapidly and are continuing to evolve, and wind turbine sizes and power ratings are continually increasing. Many of the newer wind turbine designs feature drivetrains based on Direct-Drive, Permanent-Magnet, Synchronous Generators (DD-PMSGs). Being low-speed high-torque machines, the diameters of air-cooled DD-PMSGs become very large to generate higher levels of power. The largest direct-drive wind turbine generator in operation today, rated just below 8MW, is 12m in diameter and approximately 220 tonne. To generate higher powers, traditional DD-PMSGs would need to become extraordinarily large. A 15MW air-cooled direct-drive generator would be of colossal size and tremendous mass and no longer economically viable. One alternative to increasing diameter is instead to increase torque density. In a permanent magnet machine, this is best done by increasing the linear current density of the stator windings. However, greater linear current density results in more Joule heating, and the additional heat cannot be removed practically using a traditional air-cooling approach. Direct liquid cooling is more effective, and when applied directly to the stator windings, higher linear current densities can be sustained leading to substantial increases in torque density. The higher torque density, in turn, makes possible significant reductions in DD-PMSG size. Over the past five years, a multidisciplinary team of researchers has applied a holistic approach to explore the application of liquid cooling to permanent-magnet wind turbine generator design. The approach has considered wind energy markets and the economics of wind power, system reliability, electromagnetic behaviors and design, thermal design and performance, mechanical architecture and behaviors, and the performance modeling of installed wind turbines. This dissertation is based on seven publications that chronicle the work. The primary outcomes are the proposal of a novel generator architecture, a multidisciplinary set of analyses to predict the behaviors, and experimentation to demonstrate some of the key principles and validate the analyses. The proposed generator concept is a direct-drive, surface-magnet, synchronous generator with fractional-slot, duplex-helical, double-layer, non-overlapping windings formed from a copper conductor with a coaxial internal coolant conduit to accommodate liquid coolant flow. The novel liquid-cooling architecture is referred to as LC DD-PMSG. The first of the seven publications summarized in this dissertation discusses the technological and economic benefits and limitations of DD-PMSGs as applied to wind energy. The second publication addresses the long-term reliability of the proposed LC DD-PMSG design. Publication 3 examines the machine’s electromagnetic design, and Publication 4 introduces an optimization tool developed to quickly define basic machine parameters. The static and harmonic behaviors of the stator and rotor wheel structures are the subject of Publication 5. And finally, Publications 6 and 7 examine steady-state and transient thermal behaviors. There have been a number of ancillary concrete outcomes associated with the work including the following. X Intellectual Property (IP) for direct liquid cooling of stator windings via an embedded coaxial coolant conduit, IP for a lightweight wheel structure for lowspeed, high-torque electrical machinery, and IP for numerous other details of the LC DD-PMSG design X Analytical demonstrations of the equivalent reliability of the LC DD-PMSG; validated electromagnetic, thermal, structural, and dynamic prediction models; and an analytical demonstration of the superior partial load efficiency and annual energy output of an LC DD-PMSG design X A set of LC DD-PMSG design guidelines and an analytical tool to establish optimal geometries quickly and early on X Proposed 8 MW LC DD-PMSG concepts for both inner and outer rotor configurations Furthermore, three technologies introduced could be relevant across a broader spectrum of applications. 1) The cost optimization methodology developed as part of this work could be further improved to produce a simple tool to establish base geometries for various electromagnetic machine types. 2) The layered sheet-steel element construction technology used for the LC DD-PMSG stator and rotor wheel structures has potential for a wide range of applications. And finally, 3) the direct liquid-cooling technology could be beneficial in higher speed electromotive applications such as vehicular electric drives.
Resumo:
Analytical calculation methods for all the major components of the synchronous inductance of tooth-coil permanentmagnet synchronous machines are reevaluated in this paper. The inductance estimation is different in the tooth-coil machine compared with the one in the traditional rotating field winding machine. The accuracy of the analytical torque calculation highly depends on the estimated synchronous inductance. Despite powerful finite element method (FEM) tools, an accurate and fast analytical method is required at an early design stage to find an initialmachine design structure with the desired performance. The results of the analytical inductance calculation are verified and assessed in terms of accuracy with the FEM simulation results and with the prototype measurement results.
Resumo:
The design process of direct-driven permanent magnet synchronous machines (PMSMs) for a full electric 4 ´ 4 sports car is presented. The rotor structure of the machine consists of two permanent magnet layers embedded inside the rotor laminations thus resulting in some inverse saliency, where the q-axis inductance is larger than the d-axis one. An integer slot stator winding was selected to fully take advantage of the additional reluctance torque. The performance characteristics of the designed PMSMs were calculated by applying a twodimensional finite element method. Cross-saturation between the d- and q-axes was taken into account in the calculation of the synchronous inductances. The calculation results are validated by measurements.
Resumo:
Electrical machine drives are the most electrical energy-consuming systems worldwide. The largest proportion of drives is found in industrial applications. There are, however many other applications that are also based on the use of electrical machines, because they have a relatively high efficiency, a low noise level, and do not produce local pollution. Electrical machines can be classified into several categories. One of the most commonly used electrical machine types (especially in the industry) is induction motors, also known as asynchronous machines. They have a mature production process and a robust rotor construction. However, in the world pursuing higher energy efficiency with reasonable investments not every application receives the advantage of using this type of motor drives. The main drawback of induction motors is the fact that they need slipcaused and thus loss-generating current in the rotor, and additional stator current for magnetic field production along with the torque-producing current. This can reduce the electric motor drive efficiency, especially in low-speed, low-power applications. Often, when high torque density is required together with low losses, it is desirable to apply permanent magnet technology, because in this case there is no need to use current to produce the basic excitation of the machine. This promotes the effectiveness of copper use in the stator, and further, there is no rotor current in these machines. Again, if permanent magnets with a high remanent flux density are used, the air gap flux density can be higher than in conventional induction motors. These advantages have raised the popularity of PMSMs in some challenging applications, such as hybrid electric vehicles (HEV), wind turbines, and home appliances. Usually, a correctly designed PMSM has a higher efficiency and consequently lower losses than its induction machine counterparts. Therefore, the use of these electrical machines reduces the energy consumption of the whole system to some extent, which can provide good motivation to apply permanent magnet technology to electrical machines. However, the cost of high performance rare earth permanent magnets in these machines may not be affordable in many industrial applications, because the tight competition between the manufacturers dictates the rules of low-cost and highly robust solutions, where asynchronous machines seem to be more feasible at the moment. Two main electromagnetic components of an electrical machine are the stator and the rotor. In the case of a conventional radial flux PMSM, the stator contains magnetic circuit lamination and stator winding, and the rotor consists of rotor steel (laminated or solid) and permanent magnets. The lamination itself does not significantly influence the total cost of the machine, even though it can considerably increase the construction complexity, as it requires a special assembly arrangement. However, thin metal sheet processing methods are very effective and economically feasible. Therefore, the cost of the machine is mainly affected by the stator winding and the permanent magnets. The work proposed in this doctoral dissertation comprises a description and analysis of two approaches of PMSM cost reduction: one on the rotor side and the other on the stator side. The first approach on the rotor side includes the use of low-cost and abundant ferrite magnets together with a tooth-coil winding topology and an outer rotor construction. The second approach on the stator side exploits the use of a modular stator structure instead of a monolithic one. PMSMs with the proposed structures were thoroughly analysed by finite element method based tools (FEM). It was found out that by implementing the described principles, some favourable characteristics of the machine (mainly concerning the machine size) will inevitable be compromised. However, the main target of the proposed approaches is not to compete with conventional rare earth PMSMs, but to reduce the price at which they can be implemented in industrial applications, keeping their dimensions at the same level or lower than those of a typical electrical machine used in the industry at the moment. The measurement results of the prototypes show that the main performance characteristics of these machines are at an acceptable level. It is shown that with certain specific actions it is possible to achieve a desirable efficiency level of the machine with the proposed cost reduction methods.
Resumo:
This work devotes to the theoretical investigations of spin-electromagnetic waves (SEW) propagating in a thin-film multiferroic structures that were composed of a slot-line and structures with several ferrite films. In contrast to earlier works, the spin-electromagnetic waves in the investigated structures are originated from two different electrodynamics coupling. The first one is coupling of the electromagnetic wave localized mainly in the slot-line with the spin wave excited mostly in the ferrite film. The second one is coupling of two spin waves in the different ferrite films separated by a thin ferroelectric film. For theoretical analysis of SEWs propagation in such kind of structures theories of their eigen-wave spectra were developed. Spectra of SEW in the investigated structures were calculated and analyzed. The range of electric and magnetic tunability of dispersion characteristic were investigated. Spectra of SEW in the investigated multiferroic structures are used for investigation of transfer function of periodic structures.
Resumo:
Työn tarkoitus on arvioida ja selvittää, milloin generaattorin uusinta on optimaalista tehdä vesivoimalaitoksella teknisen kunnon suhteen. Melon generaattori otettiin käyttöön vuonna 1971 ja se on peruskunnostettiin 1998. Vuonna 2009 tehdyn kuntokartoituksen mukaan koneelle annettiin laskelmien 20 vuotta elinikään. Alkuperäisessä generaattorissa on ollut ongelmia alusta asti. Alkuperäiset ongelmat pohjautuvat väärään uralukuun, joka aiheutti värinöitä koneeseen. Värinät saatiin korjattua staattorin käämitystä muuttamalla 1973 ja muutos rajoitti generaattorin tehon 33 MW:iin. Myöhemmin konetta on ajettu yli 33 MW:n teholla, joka aiheutti staattorin levypaketin aaltoilun. Aaltoilu olisi voinut aiheuttaa vakan vaurion generaattoriin. Vuonna 2014 tehdyn revision yhteydessä edellä mainitut ongelmat poistuivat. Ottaen huomioon generaattori 2 ongelmat (käyttöönotettu 1971), niin voidaan todeta, että revisio tehtiin täysin optimaaliseen aikaan.
Resumo:
Tämä työ on tehty Lappeenrannan teknilliselle yliopistolle, joka on suunnitellut ja toteuttanut hybridibussin. Hybridibussin ajomoottorissa käytetään kaksoiskäämitystä, joka mahdollistaa bussin ajamisen vikatilanteessa, jossa toinen käämityksistä on epäkunnossa. Työn tavoitteena on selvittää, millainen kaksoiskäämitys toimii parhaiten tämän hybridibussin kestomagneettiajomoottorissa. Työssä tutustutaan ajomoottoreihin ja niiltä vaadittaviin ominaisuuksiin sekä vikasietoisiin sähkömoottoreihin. Tutkimuksessa löydettyihin vikasietoisiin ajomoottoreihin perustuen päädyttiin neljään kaksoiskäämitysvaihtoehtoon. Näitä kaksoiskäämityksiä tutkittiin FE-analyysiä hyödyntäen. Kaksoiskäämitysten toimintaa simuloitiin nimellis- ja vikatilanteessa. Simuloinnin tuloksista selvisi, että kaksoiskäämitys, jossa jokaisessa urassa oli puolet yhtä käämitystä ja puolet toista (kaksoiskäämitys 1), ei toiminut kunnolla nimellistilanteessa eikä vikatilanteessa. Suurin ongelma oli vikatilanteessa aiheutuva suuri oikosulkuvirta. Kaksoiskäämitys, jossa kaksi napaa oli samaa käämitystä (kaksoiskäämitys 2), toimi moitteettomasti nimellistilanteessa. Vikatilanteen toiminnassa kuitenkin havaittiin epäjaksollisuutta magneettivuontiheydessä, mikä on haitallista moottorin käynnille ja vaaraksi roottorille. Kaksoiskäämityksiä, joista ensimmäisessä oli neljäsosa konetta samaa käämitystä (kaksoiskäämitys 3) ja toisessa puolet koneesta samaa käämitystä (kaksoiskäämitys 4), tutkittiin vikatilanteessa vain magneettivuontiheyden osalta. Puolet ja puolet käämityn koneen osalta magneettivuontiheys osottautui epäjaksolliseksi kuten oli odotettu. Neljäsosiksi käämityn koneen magneettivuontiheys oli säännöllisen jaksollinen. Nimellispisteessä kaksoiskäämityksillä 3 ja 4 havaittiin suuri vääntöväre verrattuna kaksoiskäämityksiin 1 ja 2. Johtopäätöksenä kaksoiskäämitys 3 vaikuttaa lupaavalta, mikäli suuri nimellispisteen vääntöväre saadaan hallintaan käyttämällä uravinoutta staattorissa.