22 resultados para Hydrothermal power systems
Resumo:
If electricity users adjusted their consumption patterns according to time-variable electricity prices or other signals about the state of the power system, generation and network assets could be used more efficiently, and matching intermittent renewable power generation with electricity demand would be facilitated. This kind of adjustment of electricity consumption, or demand response, may be based on consumers’ decisions to shift or reduce electricity use in response to time-variable electricity prices or on the remote control of consumers’ electric appliances. However, while demand response is suggested as a solution to many issues in power systems, actual experiences from demand response programs with residential customers are mainly limited to short pilots with a small number of voluntary participants, and information about what kinds of changes consumers are willing and able to make and what motivates these changes is scarce. This doctoral dissertation contributes to the knowledge about what kinds of factors impact on residential consumers’ willingness and ability to take part in demand response. Saving opportunities calculated with actual price data from the Finnish retail electricity market are compared with the occurred supplier switching to generate a first estimate about how large savings could trigger action also in the case of demand response. Residential consumers’ motives to participate in demand response are also studied by a web-based survey with 2103 responses. Further, experiences of households with electricity consumption monitoring systems are discussed to increase knowledge about consumers’ interest in getting more information on their electricity use and adjusting their behavior based on it. Impacts of information on willingness to participate in demand response programs are also approached by a survey for experts of their willingness to engage in demand response activities. Residential customers seem ready to allow remote control of electric appliances that does not require changes in their everyday routines. Based on residents’ own activity, the electricity consuming activities that are considered shiftable are very limited. In both cases, the savings in electricity costs required to allow remote control or to engage in demand response activities are relatively high. Nonmonetary incentives appeal to fewer households.
Resumo:
Increasingly growing share of distributed generation in the whole electrical power system’s generating system is currently a worldwide tendency, driven by several factors, encircling mainly difficulties in refinement of megalopolises’ distribution networks and its maintenance; widening environmental concerns adding to both energy efficiency approaches and installation of renewable sources based generation, inherently distributed; increased power quality and reliability needs; progress in IT field, making implementable harmonization of needs and interests of different-energy-type generators and consumers. At this stage, the volume, formed by system-interconnected distributed generation facilities, have reached the level of causing broad impact toward system operation under emergency and post-emergency conditions in several EU countries, thus previously implementable approach of their preliminary tripping in case of a fault, preventing generating equipment damage and disoperation of relay protection and automation, is not applicable any more. Adding to the preceding, withstand capability and transient electromechanical stability of generating technologies, interconnecting in proximity of load nodes, enhanced significantly since the moment Low Voltage Ride-Through regulations, followed by techniques, were introduced in Grid Codes. Both aspects leads to relay protection and auto-reclosing operation in presence of distributed generation generally connected after grid planning and construction phases. This paper proposes solutions to the emerging need to ensure correct operation of the equipment in question with least possible grid refinements, distinctively for every type of distributed generation technology achieved its technical maturity to date and network’s protection. New generating technologies are equivalented from the perspective of representation in calculation of initial steady-state short-circuit current used to dimension current-sensing relay protection, and widely adopted short-circuit calculation practices, as IEC 60909 and VDE 0102. The phenomenon of unintentional islanding, influencing auto-reclosing, is addressed, and protection schemes used to eliminate an sustained island are listed and characterized by reliability and implementation related factors, whereas also forming a crucial aspect of realization of the proposed protection operation relieving measures.
Resumo:
Tässä kandidaatintyössä selvitetään aurinkosähköjärjestelmän rakentamisen kannattavuutta, teknisiä ratkaisuja sekä vaatimuksia pientaloon. Tutkimus suoritetaan tarkasteltavaan kiinteistöön aurinkosähköjärjestelmän teknisten ratkaisumahdollisuuksien sekä taloudellisesti kannattavimman mallin löytämiseksi. Työssä käydään läpi järjestelmän teknisten komponenttien rakennetta ja ominaisuuksia, niille määriteltyjä vaatimuksia sekä hintaa. Työssä myös simuloidaan eri voimalakokonaisuuksien tuotantoa voimalan koon optimoimiseksi kohteelle. Saatujen tulosten perusteella voimalan hankkiminen on vielä kallista ja takaisinmaksuajat pitkiä johtuen järjestelmän kalliista hinnasta. Tulevaisuudessa aurinkosähkö tulee olemaan kannattava investointi samalla, kun yhä enenevissä määrin energistyvässä maailmassa luovutaan fossiilisista polttoaineista niiden ympäristövaikutusten ja resurssien puutteen vuoksi. Aurinkosähkö on yksi potentiaalisista korvaajista tulevaisuudessa ja voimme odottaa järjestelmien hintojen laskevan kilpailun lisääntyessä. Myös valtion tuki tulevaisuudessa on mahdollinen pientuottajillekin.
Resumo:
The aim of this master´s thesis is to study which processes increase the auxiliary power consumption in carbon capture and storage processes and if it is possible to reduce the auxiliary power consumption with variable speed drives. Also the cost of carbon capture and storage is studied. Data about auxiliary power consumption in carbon capture is gathered from various studies and estimates made by various research centres. Based on these studies a view is presented how the power auxiliary power consumption is divided between different processes in carbon capture processes. In a literary study, the operation of three basic carbon capture systems is described. Also different methods to transport carbon dioxide and carbon dioxide storage options are described in this section. At the end of the thesis processes that consume most of the auxiliary power are defined and possibilities to reduce the auxiliary power consumption are evaluated. Cost of carbon capture, transport and storage are also evaluated at this point and in the case that the carbon capture and storage systems are fully deployed. According to the results, it can be estimated what are the processes are where variable speed drives can be used and what kind of cost and power consumption reduction could be achieved. Results also show how large a project carbon capture and storage is if it is fully deployed.
Resumo:
The design methods and languages targeted to modern System-on-Chip designs are facing tremendous pressure of the ever-increasing complexity, power, and speed requirements. To estimate any of these three metrics, there is a trade-off between accuracy and abstraction level of detail in which a system under design is analyzed. The more detailed the description, the more accurate the simulation will be, but, on the other hand, the more time consuming it will be. Moreover, a designer wants to make decisions as early as possible in the design flow to avoid costly design backtracking. To answer the challenges posed upon System-on-chip designs, this thesis introduces a formal, power aware framework, its development methods, and methods to constraint and analyze power consumption of the system under design. This thesis discusses on power analysis of synchronous and asynchronous systems not forgetting the communication aspects of these systems. The presented framework is built upon the Timed Action System formalism, which offer an environment to analyze and constraint the functional and temporal behavior of the system at high abstraction level. Furthermore, due to the complexity of System-on-Chip designs, the possibility to abstract unnecessary implementation details at higher abstraction levels is an essential part of the introduced design framework. With the encapsulation and abstraction techniques incorporated with the procedure based communication allows a designer to use the presented power aware framework in modeling these large scale systems. The introduced techniques also enable one to subdivide the development of communication and computation into own tasks. This property is taken into account in the power analysis part as well. Furthermore, the presented framework is developed in a way that it can be used throughout the design project. In other words, a designer is able to model and analyze systems from an abstract specification down to an implementable specification.
Resumo:
Multiprocessing is a promising solution to meet the requirements of near future applications. To get full benefit from parallel processing, a manycore system needs efficient, on-chip communication architecture. Networkon- Chip (NoC) is a general purpose communication concept that offers highthroughput, reduced power consumption, and keeps complexity in check by a regular composition of basic building blocks. This thesis presents power efficient communication approaches for networked many-core systems. We address a range of issues being important for designing power-efficient manycore systems at two different levels: the network-level and the router-level. From the network-level point of view, exploiting state-of-the-art concepts such as Globally Asynchronous Locally Synchronous (GALS), Voltage/ Frequency Island (VFI), and 3D Networks-on-Chip approaches may be a solution to the excessive power consumption demanded by today’s and future many-core systems. To this end, a low-cost 3D NoC architecture, based on high-speed GALS-based vertical channels, is proposed to mitigate high peak temperatures, power densities, and area footprints of vertical interconnects in 3D ICs. To further exploit the beneficial feature of a negligible inter-layer distance of 3D ICs, we propose a novel hybridization scheme for inter-layer communication. In addition, an efficient adaptive routing algorithm is presented which enables congestion-aware and reliable communication for the hybridized NoC architecture. An integrated monitoring and management platform on top of this architecture is also developed in order to implement more scalable power optimization techniques. From the router-level perspective, four design styles for implementing power-efficient reconfigurable interfaces in VFI-based NoC systems are proposed. To enhance the utilization of virtual channel buffers and to manage their power consumption, a partial virtual channel sharing method for NoC routers is devised and implemented. Extensive experiments with synthetic and real benchmarks show significant power savings and mitigated hotspots with similar performance compared to latest NoC architectures. The thesis concludes that careful codesigned elements from different network levels enable considerable power savings for many-core systems.
Resumo:
The purpose of this master’s thesis is to gain an understanding of passive safety systems’ role in modern nuclear reactors projects and to research the failure modes of passive decay heat removal safety systems which use phenomenon of natural circulation. Another purpose is to identify the main physical principles and phenomena which are used to establish passive safety tools in nuclear power plants. The work describes passive decay heat removal systems used in AES-2006 project and focuses on the behavior of SPOT PG system. The descriptions of the main large-scale research facilities of the passive safety systems of the AES-2006 power plant are also included. The work contains the calculations of the SPOT PG system, which was modeled with thermal-hydraulic system code TRACE. The dimensions of the calculation model are set according to the dimensions of the real SPOT PG system. In these calculations three parameters are investigated as a function of decay heat power: the pressure of the system, the natural circulation mass flow rate around the closed loop, and the level of liquid in the downcomer. The purpose of the calculations is to test the ability of the SPOT PG system to remove the decay heat from the primary side of the nuclear reactor in case of failure of one, two, or three loops out of four. The calculations show that three loops of the SPOT PG system have adequate capacity to provide the necessary level of safety. In conclusion, the work supports the view that passive systems could be widely spread in modern nuclear projects.