42 resultados para Finite-Temperature
Resumo:
Selostus: Perunan ja perunahybridien jäätymisen ja fotoinhibition kestävyys
Resumo:
Selostus: Kohotettujen CO‚́‚:n ja lämpötilan vaikutukset kevätvehnän fenologiseen kehitykseen ja sadontuottomahdollisuuksiin
Resumo:
Abstract
Resumo:
Abstract
Resumo:
Abstract
Resumo:
In this study, a model for the unsteady dynamic behaviour of a once-through counter flow boiler that uses an organic working fluid is presented. The boiler is a compact waste-heat boiler without a furnace and it has a preheater, a vaporiser and a superheater. The relative lengths of the boiler parts vary with the operating conditions since they are all parts of a single tube. The present research is a part of a study on the unsteady dynamics of an organic Rankine cycle power plant and it will be a part of a dynamic process model. The boiler model is presented using a selected example case that uses toluene as the process fluid and flue gas from natural gas combustion as the heat source. The dynamic behaviour of the boiler means transition from the steady initial state towards another steady state that corresponds to the changed process conditions. The solution method chosen was to find such a pressure of the process fluid that the mass of the process fluid in the boiler equals the mass calculated using the mass flows into and out of the boiler during a time step, using the finite difference method. A special method of fast calculation of the thermal properties has been used, because most of the calculation time is spent in calculating the fluid properties. The boiler was divided into elements. The values of the thermodynamic properties and mass flows were calculated in the nodes that connect the elements. Dynamic behaviour was limited to the process fluid and tube wall, and the heat source was regarded as to be steady. The elements that connect the preheater to thevaporiser and the vaporiser to the superheater were treated in a special way that takes into account a flexible change from one part to the other. The model consists of the calculation of the steady state initial distribution of the variables in the nodes, and the calculation of these nodal values in a dynamic state. The initial state of the boiler was received from a steady process model that isnot a part of the boiler model. The known boundary values that may vary during the dynamic calculation were the inlet temperature and mass flow rates of both the heat source and the process fluid. A brief examination of the oscillation around a steady state, the so-called Ledinegg instability, was done. This examination showed that the pressure drop in the boiler is a third degree polynomial of the mass flow rate, and the stability criterion is a second degree polynomial of the enthalpy change in the preheater. The numerical examination showed that oscillations did not exist in the example case. The dynamic boiler model was analysed for linear and step changes of the entering fluid temperatures and flow rates.The problem for verifying the correctness of the achieved results was that there was no possibility o compare them with measurements. This is why the only way was to determine whether the obtained results were intuitively reasonable and the results changed logically when the boundary conditions were changed. The numerical stability was checked in a test run in which there was no change in input values. The differences compared with the initial values were so small that the effects of numerical oscillations were negligible. The heat source side tests showed that the model gives results that are logical in the directions of the changes, and the order of magnitude of the timescale of changes is also as expected. The results of the tests on the process fluid side showed that the model gives reasonable results both on the temperature changes that cause small alterations in the process state and on mass flow rate changes causing very great alterations. The test runs showed that the dynamic model has no problems in calculating cases in which temperature of the entering heat source suddenly goes below that of the tube wall or the process fluid.
Resumo:
Ultrafiltration (UF) is already used in pulp and paper industry and its demand is growing because of the required reduction of raw water intake and the separation of useful compounds from process waters. In the pulp and paper industry membranes might be exposed to extreme conditions and, therefore, it is important that the membrane can withstand them. In this study, extractives, hemicelluloses and lignin type compounds were separated from wood hydrolysate in order to be able to utilise the hemicelluloses in the production of biofuel. The performance of different polymeric membranes at different temperatures was studied. Samples were analysed for total organic compounds (TOC), lignin compounds (UV absorption at 280 nm) and sugar. Turbidity, conductivity and pH were also measured. The degree of fouling of the membranes was monitored by measuring the pure water flux before and comparing it with the pure water flux after the filtration of hydrolysate. According to the results, the retention of turbidity was observed to be higher at lower temperature compared to when the filtrations were operated at high temperature (70 °C). Permeate flux increased with elevated process temperature. There was no detrimental effect of temperature on most of the membranes used. Microdyn-Nadir regenerated cellulose membranes (RC) and GE-Osmonics thin film membranes seemed to be applicable in the chosen process conditions. The Polyethersulphone (NF-PES-10 and UH004P) and polysulphone (MPS-36) membranes used were highly fouled, but they showed high retentions for different compounds.
Resumo:
In this dissertation the main aim was to study the usability of aspen wood in the mechanical wood processes, especially the factors that affect the usability of aspen wood, which is dried at different temperature levels. The problematic of varying temperatures from level to another seem to have significant effects on distortions. According to the studies conducted, many practical solutions for drying of aspen timber can be made. European aspen sawn timber should be dried in relatively narrow widths, short lengths, edged and sawn pith free. The results achieved give an interesting view for the distortions of aspen wood between HT drying and heat treatment. The most significant result is that cupping seems to decrease when increasing temperature level from HT drying to heat treatment phase. The difference is significant. Other very obvious result is that bow and crook are increasing between these two temperature levels, bow significantly. Also the modelling gives a good background for this result since cupping is reduced by higher temperatures. It can also be assumed that these distortions can be affected for example by sorting out the timber used to different moisture levels before drying. This could be a very simple solution for practical purposes. From practical point of view, it was also noted during the drying tests performed that the discoloration seem to be no problem for aspen boards dried in temperatures under 150 °C. Altogether, this dissertation covers many interesting points of view of factors affecting distortions of wood in different temperature stages. Aspen as species in use of mechanical wood industries seems to be a species suitable for component production. According to the results, the best yield from aspen timber can be achieved in industry that can utilize relatively short components of sawn wood. Results achieved give a significant indication about the factors affecting distortions of wood at different temperature stages of drying, especially considering European aspen.
Resumo:
The focus of this dissertation is to develop finite elements based on the absolute nodal coordinate formulation. The absolute nodal coordinate formulation is a nonlinear finite element formulation, which is introduced for special requirements in the field of flexible multibody dynamics. In this formulation, a special definition for the rotation of elements is employed to ensure the formulation will not suffer from singularities due to large rotations. The absolute nodal coordinate formulation can be used for analyzing the dynamics of beam, plate and shell type structures. The improvements of the formulation are mainly concentrated towards the description of transverse shear deformation. Additionally, the formulation is verified by using conventional iso-parametric solid finite element and geometrically exact beam theory. Previous claims about especially high eigenfrequencies are studied by introducing beam elements based on the absolute nodal coordinate formulation in the framework of the large rotation vector approach. Additionally, the same high eigenfrequency problem is studied by using constraints for transverse deformation. It was determined that the improvements for shear deformation in the transverse direction lead to clear improvements in computational efficiency. This was especially true when comparative stress must be defined, for example when using elasto-plastic material. Furthermore, the developed plate element can be used to avoid certain numerical problems, such as shear and curvature lockings. In addition, it was shown that when compared to conventional solid elements, or elements based on nonlinear beam theory, elements based on the absolute nodal coordinate formulation do not lead to an especially stiff system for the equations of motion.
Resumo:
Työssä tutkittiin kestomagneettigeneraattorin staattoriytimen aksiaalisen puristamisen ja lämpötilan vaikutuksia staattorin jännityksiin ja muodonmuutoksiin. Lisäksi tutkittiin aksiaalisen puristusjännityksen vaikutusta staattorin aksiaalisuuntaisen ominaismuodon taajuuteen. Rakenteesta tehtiin elementtimalli, jonka avulla laskettiin rakenteen siirtymät, jännitykset ja ominaistaajuudet. Rakenteen jännityksiä ja siirtymiä tutkittiin myös yksinkertaisella jousikuvauksella, jonka tuloksia verrattiin elementtimallilla saatuihin tuloksiin. Työn tavoitteena oli kehittää uusi staattorirakenne. Elementtimenetelmän tulosten perusteella staattorirakennetta voidaan yksinkertaistaa poistamalla nyt käytetty puristusrengas, jolloin rakenteesta tulee yksinkertaisempi ja kustannustehokkaampi.
Resumo:
Pyörivien sähkökoneiden suunnittelussa terminen suunnittelu on yhtä tärkeää kuin sähköinen ja mekaaninen suunnittelukin. Tässä diplomityössä tarkoituksena on kehittää ilmajäähdytteisten kestomagneettigeneraattorien laskentaan soveltuva lämmönsiirtymismalli, jolla staattorin lämpötilajakauma voitaisiin selvittää. Kehitetty lämmönsiirtymismalli perustuu kolmiulotteiseen äärellisen erotuksen (finite difference) menetelmään. Malli ottaa huomioon lämmönjohtumisen staattorin aktiiviosissa ja konvektion jäähdytysilmavirtaan. Mallissa on myös yksinkertainen painehäviölaskenta jäähdytysjärjestelmän komponenttien mitoittamista varten. Laskentamallilla lasketaan esimerkkitapauksena 4,3 MW:n kestomagneettigeneraattorin jäähdytystä eri toimintapisteissä. Tuloksia verrataan CFD-mallinnuksen antamiin tuloksiin sekä kokeellisten mittausten antamiin tuloksiin.
Resumo:
A high-speed and high-voltage solid-rotor induction machine provides beneficial features for natural gas compressor technology. The mechanical robustness of the machine enables its use in an integrated motor-compressor. The technology uses a centrifugal compressor, which is mounted on the same shaft with the high-speed electrical machine driving it. No gearbox is needed as the speed is determined by the frequency converter. The cooling is provided by the process gas, which flows through the motor and is capable of transferring the heat away from the motor. The technology has been used in the compressors in the natural gas supply chain in the central Europe. New areas of application include natural gas compressors working at the wellheads of the subsea gas reservoir. A key challenge for the design of such a motor is the resistance of the stator insulation to the raw natural gas from the well. The gas contains water and heavy hydrocarbon compounds and it is far harsher than the sales gas in the natural gas supply network. The objective of this doctoral thesis is to discuss the resistance of the insulation to the raw natural gas and the phenomena degrading the insulation. The presence of partial discharges is analyzed in this doctoral dissertation. The breakdown voltage of the gas is measured as a function of pressure and gap distance. The partial discharge activity is measured on small samples representing the windings of the machine. The electrical field behavior is also modeled by finite element methods. Based on the measurements it has been concluded that the discharges are expected to disappear at gas pressures above 4 – 5 bar. The disappearance of discharges is caused by the breakdown strength of the gas, which increases as the pressure increases. Based on the finite element analysis, the physical length of a discharge seen in the PD measurements at atmospheric pressure was approximated to be 40 – 120 m. The chemical aging of the insulation when exposed to raw natural gas is discussed based on a vast set of experimental tests with the gas mixture representing the real gas mixture at the wellhead. The mixture was created by mixing dry hydrocarbon gas, heavy hydrocarbon compounds, monoethylene glycol, and water. The mixture was chosen to be more aggressive by increasing the amount of liquid substances. Furthermore, the temperature and pressure were increased, which resulted in accelerated test conditions. The time required to detect severe degradation was thus decreased. The test program included a comparison of materials, an analysis of the e ects of di erent compounds in the gas mixture, namely water and heavy hydrocarbons, on the aging, an analysis of the e ects of temperature and exposure duration, and also an analysis on the e ect of sudden pressure changes on the degradation of the insulating materials. It was found in the tests that an insulation consisting of mica, glass, and epoxy resin can tolerate the raw natural gas, but it experiences some degradation. The key material in the composite insulation is the resin, which largely defines the performance of the insulation system. The degradation of the insulation is mostly determined by the amount of gas mixture di used into it. The di usion was seen to follow Fick’s second law, but the coe cients were not accurately defined. The di usion was not sensitive to temperature, but it was dependent upon the thermodynamic state of the gas mixture, in other words, the amounts of liquid components in the gas. The weight increase observed was mostly related to heavy hydrocarbon compounds, which act as plasticizers in the epoxy resin. The di usion of these compounds is determined by the crosslink density of the resin. Water causes slight changes in the chemical structure, but these changes do not significantly contribute to the aging phenomena. Sudden changes in pressure can lead to severe damages in the insulation, because the motion of the di used gas is able to create internal cracks in the insulation. Therefore, the di usion only reduces the mechanical strength of the insulation, but the ultimate breakdown can potentially be caused by a sudden drop in the pressure of the process gas.
Resumo:
Sementti on yksi eniten maailmassa käytetty rakennusmateriaali ja Suomessa sementin valmistuksesta vastaa Finnsementti Oy kahden tehtaan voimin. Lappeenrannan tehtaalle investoitiin uusi uunilinja vuonna 2007, joka on aikansa kehittyneintä tekniikkaa. Järjes-telmän esilämmitysvaiheen laitteissa, erityisesti kalsinaattorissa, on esiintynyt luvattoman paljon plastisoitumista ja murtumia. Tässä työssä tutkittiin lämpötilan ja sen vaihtelun vaikutusta järjestelmässä syntyneisiin siirtymiin ja murtumiin. Työn alussa luotiin katsaus erilaisiin murtumisilmiöihin ja niiden syntyyn. Vuorauksessa käytettyihin tiilien käyttäytymistä tutkittiin myös, koska ne ovat olennainen osa esilämmi-tysjärjestelmää. Työn kokeellisessa osuudessa aluksi määriteltiin järjestelmässä käytetylle teräkselle lujuusominaisuudet tutkimalla mikrorakennetta sekä suorittamalla veto- että kovuuskokeet materiaalille. Toisessa osiossa mitattiin järjestelmän alasajon aikana tapah-tuneet siirtymät. Laskennallisessa osuudessa tutkittiin väsymismurtuman mahdollisuutta sekä määritettiin kuoressa esiintyvän särön vaikutusta puhkeamis- ja murtumiskuormituk-seen. FEM- analyysissä tarkasteltiin lämpötilan vaikutusta siirtymien suuruuksiin ja pyrittiin löytämään perusteluita, miksi rakenne on todellisuudessa siirtynyt eri suuntiin kuin alun perin oli tarkoitettu. Lisäksi analysoitiin FEM- mallit tiilihyllystä ja kalsinaattorin kuoren tukikehästä, joista tutkittiin lämpökuorman aiheuttamia jännityksiä. Materiaalin osalta selvisi, että kyseessä oli hyvin yleinen rakenneteräs S235 tai sitä vas-taava teräslaatu. Teräs ei ominaisuuksiltaan sovellu kuumiin olosuhteisiin, jonka vuoksi järjestelmässä käytettävän eristevuorauksen kunto on erityisen tärkeä rakenteen käyttöiän kannalta. Vuorauksen kunnosta riippuu, kuinka suuren lämpökuorman teräskuori saa. Väsymismurtuman mahdollisuus jäi minimaalisen pieneksi lämpötilan muutoksen vaiku-tuksesta. Analysoinnin tulosten perusteella voitiin todeta, että lämpötilan hitaasti mutta kohtalaisen suurella vaihteluvälillä sekä tiilien turpoamisen vaikutuksella on erittäin suuri merkitys järjestelmässä esiintyviin murtumiin.
Resumo:
Direct-driven permanent magnet synchronous generator is one of the most promising topologies for megawatt-range wind power applications. The rotational speed of the direct-driven generator is very low compared with the traditional electrical machines. The low rotational speed requires high torque to produce megawatt-range power. The special features of the direct-driven generators caused by the low speed and high torque are discussed in this doctoral thesis. Low speed and high torque set high demands on the torque quality. The cogging torque and the load torque ripple must be as low as possible to prevent mechanical failures. In this doctoral thesis, various methods to improve the torque quality are compared with each other. The rotor surface shaping, magnet skew, magnet shaping, and the asymmetrical placement of magnets and stator slots are studied not only by means of torque quality, but also the effects on the electromagnetic performance and manufacturability of the machine are discussed. The heat transfer of the direct-driven generator must be designed to handle the copper losses of the stator winding carrying high current density and to keep the temperature of the magnets low enough. The cooling system of the direct-driven generator applying the doubly radial air cooling with numerous radial cooling ducts was modeled with a lumped-parameter-based thermal network. The performance of the cooling system was discussed during the steady and transient states. The effect of the number and width of radial cooling ducts was explored. The large number of radial cooling ducts drastically increases the impact of the stack end area effects, because the stator stack consists of numerous substacks. The effects of the radial cooling ducts on the effective axial length of the machine were studied by analyzing the crosssection of the machine in the axial direction. The method to compensate the magnet end area leakage was considered. The effect of the cooling ducts and the stack end area effects on the no-load voltages and inductances of the machine were explored by using numerical analysis tools based on the three-dimensional finite element method. The electrical efficiency of the permanent magnet machine with different control methods was estimated analytically over the whole speed and torque range. The electrical efficiencies achieved with the most common control methods were compared with each other. The stator voltage increase caused by the armature reaction was analyzed. The effect of inductance saturation as a function of load current was implemented to the analytical efficiency calculation.
Resumo:
Increased emissions of greenhouse gases into the atmosphere are causing an anthropogenic climate change. The resulting global warming challenges the ability of organisms to adapt to the new temperature conditions. However, warming is not the only major threat. In marine environments, dissolution of carbon dioxide from the atmosphere causes a decrease in surface water pH, the so called ocean acidification. The temperature and acidification effects can interact, and create even larger problems for the marine flora and fauna than either of the effects would cause alone. I have used Baltic calanoid copepods (crustacean zooplankton) as my research object and studied their growth and stress responses using climate predictions projected for the next century. I have studied both direct temperature and pH effects on copepods, and indirect effects via their food: the changing phytoplankton spring bloom composition and toxic cyanobacterium. The main aims of my thesis were: 1) to find out how warming and acidification combined with a toxic cyanobacterium affect copepod reproductive success (egg production, egg viability, egg hatching success, offspring development) and oxidative balance (antioxidant capacity, oxidative damage), and 2) to reveal the possible food quality effects of spring phytoplankton bloom composition dominated by diatoms or dinoflagellates on reproducing copepods (egg production, egg hatching, RNA:DNA ratio). The two copepod genera used, Acartia sp. and Eurytemora affinis are the dominating mesozooplankton taxa (0.2 – 2 mm) in my study area the Gulf of Finland. The 20°C temperature seems to be within the tolerance limits of Acartia spp., because copepods can adapt to the temperature phenotypically by adjusting their body size. Copepods are also able to tolerate a pH decrease of 0.4 from present values, but the combination of warm water and decreased pH causes problems for them. In my studies, the copepod oxidative balance was negatively influenced by the interaction of these two environmental factors, and egg and nauplii production were lower at 20°C and lower pH, than at 20°C and ambient pH. However, presence of toxic cyanobacterium Nodularia spumigena improved the copepod oxidative balance and helped to resist the environmental stress, in question. In addition, adaptive maternal effects seem to be an important adaptation mechanism in a changing environment, but it depends on the condition of the female copepod and her diet how much she can invest in her offspring. I did not find systematic food quality difference between diatoms and dinoflagellates. There are both good and bad diatom and dinoflagellate species. Instead, the dominating species in the phytoplankton bloom composition has a central role in determining the food quality, although copepods aim at obtaining as a balanced diet as possible by foraging on several species. If the dominating species is of poor quality it can cause stress when ingested, or lead to non-optimal foraging if rejected. My thesis demonstrates that climate change induced water temperature and pH changes can cause problems to Baltic Sea copepod communities. However, their resilience depends substantially on their diet, and therefore the response of phytoplankton to the environmental changes. As copepods are an important link in pelagic food webs, their future success can have far reaching consequences, for example on fish stocks.