107 resultados para Biometano, Smart Grid Gas, AEEG
Power Electronic Converters in Low-Voltage Direct Current Distribution – Analysis and Implementation
Resumo:
Over the recent years, smart grids have received great public attention. Many proposed functionalities rely on power electronics, which play a key role in the smart grid, together with the communication network. However, “smartness” is not the driver that alone motivates the research towards distribution networks based on power electronics; the network vulnerability to natural hazards has resulted in tightening requirements for the supply security, set both by electricity end-users and authorities. Because of the favorable price development and advancements in the field, direct current (DC) distribution has become an attractive alternative for distribution networks. In this doctoral dissertation, power electronic converters for a low-voltage DC (LVDC) distribution system are investigated. These include the rectifier located at the beginning of the LVDC network and the customer-end inverter (CEI) on the customer premises. Rectifier topologies are introduced, and according to the LVDC system requirements, topologies are chosen for the analysis. Similarly, suitable CEI topologies are addressed and selected for study. Application of power electronics into electricity distribution poses some new challenges. Because the electricity end-user is supplied with the CEI, it is responsible for the end-user voltage quality, but it also has to be able to supply adequate current in all operating conditions, including a short-circuit, to ensure the electrical safety. Supplying short-circuit current with power electronics requires additional measures, and therefore, the short-circuit behavior is described and methods to overcome the high-current supply to the fault are proposed. Power electronic converters also produce common-mode (CM) and radio-frequency (RF) electromagnetic interferences (EMI), which are not present in AC distribution. Hence, their magnitudes are investigated. To enable comprehensive research on the LVDC distribution field, a research site was built into a public low-voltage distribution network. The implementation was a joint task by the LVDC research team of Lappeenranta University of Technology and a power company Suur-Savon S¨ahk¨o Oy. Now, the measurements could be conducted in an actual environment. This is important especially for the EMI studies. The main results of the work concern the short-circuit operation of the CEI and the EMI issues. The applicability of the power electronic converters to electricity distribution is demonstrated, and suggestions for future research are proposed.
Resumo:
The research towards efficient, reliable and environmental-friendly power supply solutions is producing growing interest to the “Smart Grid” approach for the development of the electricity networks and managing the increasing energy consumption. One of the novel approaches is an LVDC microgrid. The purpose of the research is to analyze the possibilities for the implementation of LVDC microgrids in public distribution networks in Russia. The research contains the analysis of the modern Russian electric power industry, electricity market, electricity distribution business, regulatory framework and standardization, related to the implementation of LVDC microgrid concept. For the purpose of the economic feasibility estimation, a theoretical case study for comparing low voltage AC and medium voltage AC with LVDC microgrid solutions for a small settlement in Russia is presented. The results of the market and regulatory framework analysis along with the economic comparison of AC and DC solutions show that implementation of the LVDC microgrid concept in Russia is possible and can be economically feasible. From the electric power industry and regulatory framework point of view, there are no serious obstacles for the LVDC microgrids in Russian distribution networks. However, the most suitable use cases at the moment are expected to be found in the electrification of remote settlements, which are isolated from the Unified Energy System of Russia.
Resumo:
Lappeenrannan teknillinen yliopisto tutkii pientasajännitesähkön käyttöä. Yliopisto on rakennuttanut Järvi-Suomen Energia Oy:n ja Suur-Savon Sähkö Oy:n kanssa yhteistyössä kokeellisen pientasajännitesähköverkon, jolla pystytään tarjoamaan kenttäolosuhteet pienjännitetutkimukselle todellisilla asiakkailla ja todentaa LVDC-teknologiaa ja muita älykkään sähköverkon toimintoja kenttäolosuhteissa. Verkon tasajänniteyhteys on rakennettu 20 kV sähkönjakeluverkon ja neljän kuluttajan välille. 20 kV keskijännite suunnataan tasamuuntamolla ±750 V pientasajännitteeksi ja uudestaan 400/230 V vaihtojännitteeksi kuluttajien läheisyydessä. Tämän kandidaatintyön tarkoituksena on luoda yliopistolle tietokanta pientasajännitesähköverkosta kertyvälle tiedolle ja mittaustuloksille. Tietokanta nähtiin tarpeelliseksi luoda, jotta pienjänniteverkon mittaustuloksia pystytään myöhemmin tarkastelemaan yhdessä ja yhtenäisessä muodossa. Yhdeksi tutkimuskysymykseksi muodostui, kuinka järjestää ja visualisoida kaikki verkosta palvelimille kertyvä mittausdata. Työssä on huomioitu myös kolme tietokantaa mahdollisesti hyödyntävää käyttäjäryhmää: kotitalousasiakkaat, sähköverkkoyhtiöt ja tutkimuslaboratorio, sekä pohdittu tietokannan hyötyä ja merkitystä näille käyttäjille. Toiseksi tutkimuskysymykseksi muodostuikin, mikä kaikesta tietokantaan talletetusta datasta olisi oleellisen tärkeää ottaa talteen näiden asiakkaiden kannalta, ja kuinka nämä voisivat hakea tietoa tietokannasta. Työn tutkimusmenetelmät perustuvat jo valmiiksi olemassa olevaan mittausdataan. Työtä varten on käytetty sekä painettua että sähköisessä muodossa olevaa kirjallisuutta. Työn tuloksena on saatu luotua tietokanta MySQL Workbench -ohjelmistolla, sekä mittausdatan keräys- ja käsittelyohjelmat Python-ohjelmointikielellä. Lisäksi on luotu erillinen MATLAB-rajapinta tiedon visualisoimista varten, jolla havainnollistetaan kolmen asiakasryhmän mittausdataa. Tietokanta ja sen tiedon visualisointi antavat kuluttajalle mahdollisuuden ymmärtää paremmin omaa sähkönkäyttöään, sekä sähköverkkoyhtiöille ja tutkimuslaboratorioille muun muassa tietoa sähkön laadusta ja verkon kuormituksesta.
Resumo:
This work deals with the cooling of high-speed electric machines, such as motors and generators, through an air gap. It consists of numerical and experimental modelling of gas flow and heat transfer in an annular channel. Velocity and temperature profiles are modelled in the air gap of a high-speed testmachine. Local and mean heat transfer coefficients and total friction coefficients are attained for a smooth rotor-stator combination at a large velocity range. The aim is to solve the heat transfer numerically and experimentally. The FINFLO software, developed at Helsinki University of Technology, has been used in the flow solution, and the commercial IGG and Field view programs for the grid generation and post processing. The annular channel is discretized as a sector mesh. Calculation is performed with constant mass flow rate on six rotational speeds. The effect of turbulence is calculated using three turbulence models. The friction coefficient and velocity factor are attained via total friction power. The first part of experimental section consists of finding the proper sensors and calibrating them in a straight pipe. After preliminary tests, a RdF-sensor is glued on the walls of stator and rotor surfaces. Telemetry is needed to be able to measure the heat transfer coefficients at the rotor. The mean heat transfer coefficients are measured in a test machine on four cooling air mass flow rates at a wide Couette Reynolds number range. The calculated values concerning the friction and heat transfer coefficients are compared with measured and semi-empirical data. Heat is transferred from the hotter stator and rotor surfaces to the coolerair flow in the air gap, not from the rotor to the stator via the air gap, althought the stator temperature is lower than the rotor temperature. The calculatedfriction coefficients fits well with the semi-empirical equations and precedingmeasurements. On constant mass flow rate the rotor heat transfer coefficient attains a saturation point at a higher rotational speed, while the heat transfer coefficient of the stator grows uniformly. The magnitudes of the heat transfer coefficients are almost constant with different turbulence models. The calibrationof sensors in a straight pipe is only an advisory step in the selection process. Telemetry is tested in the pipe conditions and compared to the same measurements with a plain sensor. The magnitudes of the measured data and the data from the semi-empirical equation are higher for the heat transfer coefficients than thenumerical data considered on the velocity range. Friction and heat transfer coefficients are presented in a large velocity range in the report. The goals are reached acceptably using numerical and experimental research. The next challenge is to achieve results for grooved stator-rotor combinations. The work contains also results for an air gap with a grooved stator with 36 slots. The velocity field by the numerical method does not match in every respect the estimated flow mode. The absence of secondary Taylor vortices is evident when using time averagednumerical simulation.
Resumo:
This study examines Smart Grids and distributed generation, which is connected to a single-family house. The distributed generation comprises small wind power plant and solar panels. The study is done from the consumer point of view and it is divided into two parts. The first part presents the theoretical part and the second part presents the research part. The theoretical part consists of the definition of distributed generation, wind power, solar energy and Smart Grids. The study examines what the Smart Grids will enable. New technology concerning Smart Grids is also examined. The research part introduces wind and sun conditions from two countries. The countries are Finland and Germany. According to the wind and sun conditions of these two countries, the annual electricity production from wind power plant and solar panels will be calculated. The costs of generating electricity from wind and solar energy are calculated from the results of annual electricity productions. The study will also deal with feed-in tariffs, which are supporting systems for renewable energy resources. It is examined in the study, if it is cost-effective for the consumers to use the produced electricity by themselves or sell it to the grid. Finally, figures for both countries are formed. The figures include the calculated cost of generating electricity from wind power plant and solar panels, retail and wholesale prices and feed-in tariffs. In Finland, it is not cost-effective to sell the produced electricity to the grid, before there are support systems. In Germany, it is cost-effective to sell the produced electricity from solar panels to the grid because of feed-in tariffs. On the other hand, in Germany it is cost-effective to produce electricity from wind to own use because the retail price is higher than the produced electricity from wind.
Resumo:
This thesis is done as a part of the NEOCARBON project. The aim of NEOCARBON project is to study a fully renewable energy system utilizing Power-to-Gas or Power-to-Liquid technology for energy storage. Power-to-Gas consists of two main operations: Hydrogen production via electrolysis and methane production via methanation. Methanation requires carbon dioxide and hydrogen as a raw material. This thesis studies the potential carbon dioxide sources within Finland. The different sources are ranked using the cost and energy penalty of the carbon capture, carbon biogenity and compatibility with Power-to-Gas. It can be concluded that in Finland there exists enough CO2 point sources to provide national PtG system with sufficient amounts of carbon. Pulp and paper industry is single largest producer of biogenic CO2 in Finland. It is possible to obtain single unit capable of grid balancing operations and energy transformations via Power-to-Gas and Gas-to-Power by coupling biogas plants with biomethanation and CHP units.
Resumo:
Increasing amount of renewable energy source based electricity production has set high load control requirements for power grid balance markets. The essential grid balance between electricity consumption and generation is currently hard to achieve economically with new-generation solutions. Therefore conventional combustion power generation will be examined in this thesis as a solution to the foregoing issue. Circulating fluidized bed (CFB) technology is known to have sufficient scale to acts as a large grid balancing unit. Although the load change rate of the CFB unit is known to be moderately high, supplementary repowering solution will be evaluated in this thesis for load change maximization. The repowering heat duty is delivered to the CFB feed water preheating section by smaller gas turbine (GT) unit. Consequently, steam extraction preheating may be decreased and large amount of the gas turbine exhaust heat may be utilized in the CFB process to reach maximum plant electrical efficiency. Earlier study of the repowering has focused on the efficiency improvements and retrofitting to maximize plant electrical output. This study however presents the CFB load change improvement possibilities achieved with supplementary GT heat. The repowering study is prefaced with literature and theory review for both of the processes to maximize accuracy of the research. Both dynamic and steady-state simulations accomplished with APROS simulation tool will be used to evaluate repowering effects to the CFB unit operation. Eventually, a conceptual level analysis is completed to compare repowered plant performance to the state-of-the-art CFB performance. Based on the performed simulations, considerably good improvements to the CFB process parameters are achieved with repowering. Consequently, the results show possibilities to higher ramp rate values achieved with repowered CFB technology. This enables better plant suitability to the grid balance markets.
Resumo:
Centrifugal compressors are widely used for example in process industry, oil and gas industry, in small gas turbines and turbochargers. In order to achieve lower consumption of energy and operation costs the efficiency of the compressor needs to be improve. In the present work different pinches and low solidity vaned diffusers were utilized in order to improve the efficiency of a medium size centrifugal compressor. In this study, pinch means the decrement of the diffuser flow passage height. First different geometries were analyzed using computational fluid dynamics. The flow solver Finflo was used to solve the flow field. Finflo is a Navier-Stokes solver. The solver is capable to solve compressible, incompressible, steady and unsteady flow fields. Chien's k-e turbulence model was used. One of the numerically investigated pinched diffuser and one low solidity vaned diffuser were studied experimentally. The overall performance of the compressor and the static pressure distribution before and after the diffuser were measured. The flow entering and leaving the diffuser was measured using a three-hole Cobra-probe and Kiel-probes. The pinch and the low solidity vaned diffuser increased the efficiency of the compressor. Highest isentropic efficiency increment obtained was 3\% of the design isentropic efficiency of the original geometry. It was noticed in the numerical results that the pinch made to the hub and the shroud wall was most beneficial to the operation of the compressor. Also the pinch made to the hub was better than the pinchmade to the shroud. The pinch did not affect the operation range of the compressor, but the low solidity vaned diffuser slightly decreased the operation range.The unsteady phenomena in the vaneless diffuser were studied experimentally andnumerically. The unsteady static pressure was measured at the diffuser inlet and outlet, and time-accurate numerical simulation was conducted. The unsteady static pressure showed that most of the pressure variations lay at the passing frequency of every second blade. The pressure variations did not vanish in the diffuser and were visible at the diffuser outlet. However, the amplitude of the pressure variations decreased in the diffuser. The time-accurate calculations showed quite a good agreement with the measured data. Agreement was very good at the design operation point, even though the computational grid was not dense enough inthe volute and in the exit cone. The time-accurate calculation over-predicted the amplitude of the pressure variations at high flow.
Resumo:
Tämän diplomityön tavoitteena on kartoittaa Vaahto Oy:n Hollolan tehtaan energiankulutus ja energiansäästökohteet. Ensin tutkittiin tehtaan energiankulutus ja energiankulutuksen jakautuminen. Tutkimuksessa käytettiin saatavilla olevia kulutustietoja, luettiin konekirjoja sekä haastateltiin tehtaan työntekijöitä. Lisäksi tehdashallien lämmityslaitteiden hyötysuhteet mitattiin. Tutkimuksen päätavoite oli selvittää, miksi tehtaan lämmitysenergiankulutus on kasvanut ja kannattaisiko rakennusten lämmittämiseen käyttää vaihtoehtoista lämmitysmuotoa öljylämmitykselle. Potentiaalisista energiansäästökohteista tehtiin investointilaskelmat ja toimenpide-ehdotukset. Kannattaviksi toimenpiteiksi tutkimuksessa todettiin: lämmityspolttoaineen vaihtaminen maakaasuun, nosto-ovien hankkiminen, paineilmaverkon huolto, paineilmakompressorin lämmöntalteenotto, tehdastilojen sisälämpötilan tarkastus ja työnjohtotilojen ilmanvaihdon käyntiaikojen muutos. Toimenpiteillä arvioidaan vuotuisten energiakustannusten pienenevän noin 34 000 euroa. Toimenpiteiden toteuttamisen arvioidaan maksavan 135 000 ¤, mistä lämmitysjärjestelmän vaihdon osuus on 100 000 ¤.
Resumo:
Diplomityössä kehitetään malli tiheän kaksifaasivirtauksen aiheuttaman eroosiokulumi-sen mallintamiseksi, ratkaistaan virtauskenttä kahdessa erilaisessa keskipakopumpussa, sovelletaan kehitettyä mallia, sekävertaillaan mallin antamia tuloksia käytännön kokeissa saavutettuihin tuloksiin. Työssä on erityisenä mielenkiinnon kohteena savukaasupesurin pumppu. Työn alkuosa sisältää tarkemman kuvauksen savukaasupesurin toi-minnasta. Numeerinen ratkaisu ja laskentahilan generointi suoritetaan ANSYS CFX- ja Turbo-Grid-ohjelmistoilla. Laskennassa virtauksen Navier-Stokesin yhtälöt on aikakeskiarvo-tettu ja ratkaistu käyttäen kontrollitilavuusmenetelmää. Tiheiden kaksifaasivirtausten eroosiokulumista on mallinnettu tekijän kehittämällä mallilla, jonka käytännön toteutus-ta ei kuitenkaan saateta julkiseksi, koodin kehittämisessä käytetty teoria on kuitenkin esitetty työssä. Työn piirissä tehtiin myös kulumiskokeita Sulzer Pumps Finlandin Karhulan tehtailla, sekä vertailtiin simuloinnin tuloksia aikaisemmissa kokeissa saavutettuihin. Koejärjestelyt kuvataan työssä.
Resumo:
In bubbly flow simulations, bubble size distribution is an important factor in determination of hydrodynamics. Beside hydrodynamics, it is crucial in the prediction of interfacial area available for mass transfer and in the prediction of reaction rate in gas-liquid reactors such as bubble columns. Solution of population balance equations is a method which can help to model the size distribution by considering continuous bubble coalescence and breakage. Therefore, in Computational Fluid Dynamic simulations it is necessary to couple CFD and Population Balance Model (CFD-PBM) to get reliable distribution. In the current work a CFD-PBM coupled model is implemented as FORTRAN subroutines in ANSYS CFX 10 and it has been tested for bubbly flow. This model uses the idea of Multi Phase Multi Size Group approach which was previously presented by Sha et al. (2006) [18]. The current CFD-PBM coupled method considers inhomogeneous flow field for different bubble size groups in the Eulerian multi-dispersed phase systems. Considering different velocity field for bubbles can give the advantageof more accurate solution of hydrodynamics. It is also an improved method for prediction of bubble size distribution in multiphase flow compared to available commercial packages.
Resumo:
Tutkimus suomalaisten yritysten liiketoimintamahdollisuuksista hiilidoksidipäästöjen vähentämisen parissa Luoteis-Venäjällä.
Resumo:
Small centrifugal compressors are more and more widely used in many industrialsystems because of their higher efficiency and better off-design performance comparing to piston and scroll compressors as while as higher work coefficient perstage than in axial compressors. Higher efficiency is always the aim of the designer of compressors. In the present work, the influence of four partsof a small centrifugal compressor that compresses heavy molecular weight real gas has been investigated in order to achieve higher efficiency. Two parts concern the impeller: tip clearance and the circumferential position of the splitter blade. The other two parts concern the diffuser: the pinch shape and vane shape. Computational fluid dynamics is applied in this study. The Reynolds averaged Navier-Stokes flow solver Finflo is used. The quasi-steady approach is utilized. Chien's k-e turbulence model is used to model the turbulence. A new practical real gas model is presented in this study. The real gas model is easily generated, accuracy controllable and fairly fast. The numerical results and measurements show good agreement. The influence of tip clearance on the performance of a small compressor is obvious. The pressure ratio and efficiency are decreased as the size of tip clearance is increased, while the total enthalpy rise keeps almost constant. The decrement of the pressure ratio and efficiency is larger at higher mass flow rates and smaller at lower mass flow rates. The flow angles at the inlet and outlet of the impeller are increased as the size of tip clearance is increased. The results of the detailed flow field show that leakingflow is the main reason for the performance drop. The secondary flow region becomes larger as the size of tip clearance is increased and the area of the main flow is compressed. The flow uniformity is then decreased. A detailed study shows that the leaking flow rate is higher near the exit of the impeller than that near the inlet of the impeller. Based on this phenomenon, a new partiallyshrouded impeller is used. The impeller is shrouded near the exit of the impeller. The results show that the flow field near the exit of the impeller is greatly changed by the partially shrouded impeller, and better performance is achievedthan with the unshrouded impeller. The loading distribution on the impeller blade and the flow fields in the impeller is changed by moving the splitter of the impeller in circumferential direction. Moving the splitter slightly to the suction side of the long blade can improve the performance of the compressor. The total enthalpy rise is reduced if only the leading edge of the splitter ismoved to the suction side of the long blade. The performance of the compressor is decreased if the blade is bended from the radius direction at the leading edge of the splitter. The total pressure rise and the enthalpy rise of thecompressor are increased if pinch is used at the diffuser inlet. Among the fivedifferent pinch shape configurations, at design and lower mass flow rates the efficiency of a straight line pinch is the highest, while at higher mass flow rate, the efficiency of a concave pinch is the highest. The sharp corner of the pinch is the main reason for the decrease of efficiency and should be avoided. The variation of the flow angles entering the diffuser in spanwise direction is decreased if pinch is applied. A three-dimensional low solidity twisted vaned diffuser is designed to match the flow angles entering the diffuser. The numerical results show that the pressure recovery in the twisted diffuser is higher than in a conventional low solidity vaned diffuser, which also leads to higher efficiency of the twisted diffuser. Investigation of the detailed flow fields shows that the separation at lower mass flow rate in the twisted diffuser is later than in the conventional low solidity vaned diffuser, which leads to a possible wider flow range of the twisted diffuser.