29 resultados para BRASS ELECTRODES


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Original sludge from wastewater treatment plants (WWTPs) usually has a poor dewaterability. Conventionally, mechanical dewatering methods are used to increase the dry solids (DS) content of the sludge. However, sludge dewatering is an important economic factor in the operation of WWTPs, high water content in the final sludge cake is commonly related to an increase in transport and disposal costs. Electro‐dewatering could be a potential technique to reduce the water content of the final sludge cake, but the parameters affecting the performance of electro‐dewatering and the quality of the resulting sludge cake, as well as removed water, are not sufficiently well known. In this research, non‐pressure and pressure‐driven experiments were set up to investigate the effect of various parameters and experimental strategies on electro‐dewatering. Migration behaviour of organic compounds and metals was also studied. Application of electrical field significantly improved the dewatering performance in comparison to experiments without electric field. Electro‐dewatering increased the DS content of the sludge from 15% to 40 % in non‐pressure applications and from 8% to 41% in pressure‐driven applications. DS contents were significantly higher than typically obtained with mechanical dewatering techniques in wastewater treatment plant. The better performance of the pressure‐driven dewatering was associated to a higher current density at the beginning and higher electric field strength later on in the experiments. The applied voltage was one of the major parameters affecting dewatering time, water removal rate and DS content of the sludge cake. By decreasing the sludge loading rate, higher electrical field strength was established between the electrodes, which has a positive effect on an increase in DS content of the final sludge cake. However interrupted voltage application had anegative impact on dewatering in this study, probably because the off‐times were too long. Other factors affecting dewatering performance were associated to the original sludge characteristics and sludge conditioning. Anaerobic digestion of the sludge with high pH buffering capacity, polymer addition and freeze/thaw conditioning had a positive impact on dewatering. The impact of pH on electro‐dewatering was related to the surface charge of the particles measured as zeta‐potential. One of the differences between electro‐dewatering and mechanical dewatering technologies is that electro‐dewatering actively removes ionic compounds from the sludge. In this study, dissolution and migration of organic compounds (such as shortchain fatty acids), macro metals (Na, K, Ca, Mg, Fe) and trace metals (Ni, Mn, Zn, Cr) was investigated. The migration of the metals depended on the fractionation and electrical field strength. These compounds may have both negative and positive impacts on the reuse and recycling of the sludge and removed water. Based on the experimental results of this study, electro‐dewatering process can be optimized in terms of dewatering time, desired DS content, power consumption and chemical usage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chemical coagulation is commonly used in raw water and wastewater treatment plants for the destabilisation of pollutants so that they can be removed in the subsequent separation processes. The most commonly used coagulation chemicals are aluminium and iron metal salts. Electrocoagulation technology has also been proposed for the treatment of raw waters and wastewaters. With this technology, metal cations are produced on the electrodes via electrolysis and these cations form various hydroxides in the water depending on the water pH. In addition to this main reaction, several side reactions, such as hydrogen bubble formation and the reduction of metals on cathodes, also take place in the cell. In this research, the applications of electrocoagulation were investigated in raw water treatment and wastewater applications. The surface water used in this research contained high concentrations of natural organic matter (NOM). The effect of the main parameters – current density, initial pH, electric charge per volume, temperature and electrolysis cell construction – on NOM removal were investigated. In the wastewater treatment studies, the removal of malodorous sulphides and toxic compounds from the wastewaters and debarking effluents were studied. Also, the main parameters of the treatment, such as initial pH and current density, were investigated. Aluminium electrodes were selected for the raw water treatment, whereas wastewaters and debarking effluent were treated with iron electrodes. According to results of this study, aluminium is more suitable electrode material for electrocoagulation applications because it produces Al(III) species. Metal ions and hydroxides produced by iron electrodes are less effective in the destabilisation of pollutants because iron electrodes produce more soluble and less charged Fe(II) species. However, Fe(II) can be effective in some special applications, such as sulphide removal. The resulting metal concentration is the main parameter affecting destabilisation of pollutants. Current density, treatment time, temperature and electrolysis cell construction affect the dissolution of electrodes and hence also the removal of pollutants. However, it seems that these parameters have minimal significance in the destabilization of the pollutants besides this effect (in the studied range of parameters). Initial pH and final pH have an effect on the dissolution of electrodes, but they also define what aluminium or iron species are formed in the solution and have an effect on the ζ-potential of all charged species in the solution. According to the results of this study, destabilisation mechanisms of pollutants by electrocoagulation and chemical coagulation are similar. Optimum DOC removal and low residual aluminium can be obtained simultaneously with electrocoagulation, which may be a significant benefit of electrocoagulation in surface water treatment compared to chemical coagulation. Surface water treatment with electrocoagulation can produce high quality water, which could be used as potable water or fresh water for industrial applications. In wastewater treatment applications, electrocoagulation can be used to precipitate malodorous sulphides to prevent their release into air. Technology seems to be able to remove some toxic pollutants from wastewater and could be used as pretreatment prior to treatment at a biological wastewater treatment plant. However, a thorough economic and ecological comparison of chemical coagulation and electrocoagulation is recommended, because these methods seem to be similar in pollutant destabilisation mechanisms, metal consumption and removal efficiency in most applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Superconductor – normal metal point contacts were investigated, using different combinations of Cu, brass, Nb and NbTi. The resulting spectra contained side peaks. The currents at which these side peaks appeared, depended on the radii of the contacts. For contacts with Nb this dependence was quadratic, while for contacts with NbTi it was linear. Based on this, we argue that the side peaks in the case of the Nb contacts are due to the critical current density being exceeded. In contrast, side peaks of the NbTi contacts are caused by the self-magnetic field exceeding the lower critical field of NbTi. The NbTi contacts did not show the expected contribution from the vanishing Maxwell resistance of the superconductor, a question which remained open.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Interest in water treatment by electrochemical methods has grown in recent years. Electrochemical oxidation has been applied particularly successfully to degrade different organic pollutants and disinfect drinking water. This study summarizes the effectiveness of the electrochemical oxidation technique in inactivating different primary biofilm forming paper mill bacteria as well as sulphide and organic material in pulp and paper mill wastewater in laboratory scale batch experiments. Three different electrodes, borondoped diamond (BDD), mixed metal oxide (MMO) and PbO2, were employed as anodes. The impact on inactivation efficiency of parameters such as current density and initial pH or chloride concentration of synthetic paper machine water was studied. The electrochemical behaviour of the electrodes was investigated by cyclic voltammetry with MMO, BDD and PbO2 electrodes in synthetic paper mill water as also with MMO and stainless steel electrodes with biocides. Some suggestions on the formation of different oxidants and oxidation mechanisms were also presented during the treatment. Aerobic paper mill bacteria species (Deinococcus geothermalis, Pseudoxanthomonas taiwanensis and Meiothermus silvanus) were inactivated effectively (>2 log) at MMO electrodes by current density of 50 mA/cm2 and the time taken three minutes. Increasing current density and initial chloride concentration of paper mill water increased the inactivation rate of Deinococcus geothermalis. The inactivation order of different bacteria species was Meiothermus silvanus > Pseudoxanthomonas taiwanensis > Deinococcus geothermalis. It was observed that inactivation was mainly due to the electrochemically generated chlorine/hypochlorite from chloride present in the water and also residual disinfection by chlorine/hypochlorite occurred. In real paper mill effluent treatment sulphide oxidation was effective with all the different initial concentrations (almost 100% reduction, current density 42.9 mA/cm2) and also anaerobic bacteria inactivation was observed (almost 90% reduction by chloride concentration of 164 mg/L and current density of 42.9 mA/cm2 in five minutes). Organic material removal was not as effective when comparing with other tested techniques, probably due to the relatively low treatment times. Cyclic voltammograms in synthetic paper mill water with stainless steel electrode showed that H2O2 could be degraded to radicals during the cathodic runs. This emphasises strong potential of combined electrochemical treatment with this biocide in bacteria inactivation in paper mill environments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Potentiometric ion sensors are a very important subgroup of electrochemical sensors, very attractive for practical applications due to their small size, portability, low-energy consumption, relatively low cost and not changing the sample composition. They are investigated by the researchers from many fields of science. The continuous development of this field creates the necessity for a detailed description of sensor response and the electrochemical processes important in the practical applications of ion sensors. The aim of this thesis is to present the existing models available for the description of potentiometric ion sensors as well as their applicability and limitations. This includes the description of the diffusion potential occurring at the reference electrodes. The wide range of existing models, from most idealised phase boundary models to most general models, including migration, is discussed. This work concentrates on the advanced modelling of ion sensors, namely the Nernst-Planck-Poisson (NPP) model, which is the most general of the presented models, therefore the most widely applicable. It allows the modelling of the transport processes occurring in ion sensors and generating the potentiometric response. Details of the solution of the NPP model (including the numerical methods used) are shown. The comparisons between NPP and the more idealized models are presented. The applicability of the model to describe the formation of diffusion potential in reference electrode, the lower detection limit of both ion-exchanger and neutral carrier electrodes and the effect of the complexation in the membrane are discussed. The model was applied for the description of both types of electrodes, i.e. with the inner filling solution and solidcontact electrodes. The NPP model allows the electrochemical methods other than potentiometry to be described. Application of this model in Electrochemical Impedance Spectroscopy is discussed and a possible use in chrono-potentiometry is indicated. By combining the NPP model with evolutionary algorithms, namely Hierarchical Genetic Strategy (HGS), a novel method allowing the facilitation of the design of ion sensors was created. It is described in detail in this thesis and its possible applications in the field of ion sensors are indicated. Finally, some interesting effects occurring in the ion sensors (i.e. overshot response and influence of anionic sites) as well as the possible applications of NPP in biochemistry are described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mass-produced paper electronics (large area organic printed electronics on paper-based substrates, “throw-away electronics”) has the potential to introduce the use of flexible electronic applications in everyday life. While paper manufacturing and printing have a long history, they were not developed with electronic applications in mind. Modifications to paper substrates and printing processes are required in order to obtain working electronic devices. This should be done while maintaining the high throughput of conventional printing techniques and the low cost and recyclability of paper. An understanding of the interactions between the functional materials, the printing process and the substrate are required for successful manufacturing of advanced devices on paper. Based on the understanding, a recyclable, multilayer-coated paper-based substrate that combines adequate barrier and printability properties for printed electronics and sensor applications was developed in this work. In this multilayer structure, a thin top-coating consisting of mineral pigments is coated on top of a dispersion-coated barrier layer. The top-coating provides well-controlled sorption properties through controlled thickness and porosity, thus enabling optimizing the printability of functional materials. The penetration of ink solvents and functional materials stops at the barrier layer, which not only improves the performance of the functional material but also eliminates potential fiber swelling and de-bonding that can occur when the solvents are allowed to penetrate into the base paper. The multi-layer coated paper under consideration in the current work consists of a pre-coating and a smoothing layer on which the barrier layer is deposited. Coated fine paper may also be used directly as basepaper, ensuring a smooth base for the barrier layer. The top layer is thin and smooth consisting of mineral pigments such as kaolin, precipitated calcium carbonate, silica or blends of these. All the materials in the coating structure have been chosen in order to maintain the recyclability and sustainability of the substrate. The substrate can be coated in steps, sequentially layer by layer, which requires detailed understanding and tuning of the wetting properties and topography of the barrier layer versus the surface tension of the top-coating. A cost competitive method for industrial scale production is the curtain coating technique allowing extremely thin top-coatings to be applied simultaneously with a closed and sealed barrier layer. The understanding of the interactions between functional materials formulated and applied on paper as inks, makes it possible to create a paper-based substrate that can be used to manufacture printed electronics-based devices and sensors on paper. The multitude of functional materials and their complex interactions make it challenging to draw general conclusions in this topic area. Inevitably, the results become partially specific to the device chosen and the materials needed in its manufacturing. Based on the results, it is clear that for inks based on dissolved or small size functional materials, a barrier layer is beneficial and ensures the functionality of the printed material in a device. The required active barrier life time depends on the solvents or analytes used and their volatility. High aspect ratio mineral pigments, which create tortuous pathways and physical barriers within the barrier layer limit the penetration of solvents used in functional inks. The surface pore volume and pore size can be optimized for a given printing process and ink through a choice of pigment type and coating layer thickness. However, when manufacturing multilayer functional devices, such as transistors, which consist of several printed layers, compromises have to be made. E.g., while a thick and porous top-coating is preferable for printing of source and drain electrodes with a silver particle ink, a thinner and less absorbing surface is required to form a functional semiconducting layer. With the multilayer coating structure concept developed in this work, it was possible to make the paper substrate suitable for printed functionality. The possibility of printing functional devices, such as transistors, sensors and pixels in a roll-to-roll process on paper is demonstrated which may enable introducing paper for use in disposable “onetime use” or “throwaway” electronics and sensors, such as lab-on-strip devices for various analyses, consumer packages equipped with product quality sensors or remote tracking devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Advanced oxidation processes (AOPs) have been studied and developed to suffice the effective removal of refractory and toxic compounds in polluted water. The quality and cost of wastewater treatment need improvements, and electric discharge technology has a potential to make a significant difference compared to other established AOPs based on energy efficiency. The generation of active oxidant species such as ozone and hydroxyl radicals by high voltage discharge is a relatively new technology for water treatment. Gas-phase pulsed corona discharge (PCD), where a treated aqueous solution is dispersed between corona-producing electrodes free of the dielectric barriers, was developed as an alternative approach to the problem. The short living radicals and ozone formed in the gas phase and at the gas-liquid interface react with dissolved impurities. PCD equipment has a relatively simple configuration, and with the reactor in an enclosed compartment, it is insensitive towards gas humidity and does not need the gas transport. In this thesis, PCD was used to study and evaluate the energy efficiency for degrading various organic compounds, as well as the chemistry of the oxidation products formed. The experiments investigate the aqueous oxidation of phenol, humic substances, pharmaceutical compounds (paracetamol, ibuprofen, indomethacin, salicylic acids, -estradiol), as well as lignin degradation and transformation to aldehydes. The study aims to establish the influence of initial concentration of the target pollutant, the pulsed discharge parameters, gas phase composition and the pH on the oxidation kinetics and the efficiency. Analytical methods to measure the concentrations of the target compounds and their by-products include HPLC, spectrophotometry, TOC and capillary electrophoresis. The results of the research included in this summary are presented in the attached publications and manuscripts accepted for publication. Pulsed corona discharge proved to be highly effective in oxidizing each of the target compounds, surpassing the closest competitor, conventional ozonation. The increase in oxidation efficiencies for some compounds in oxygen media and at lower pulse repetition frequencies shows a significant role of ozone. The role of the ·OH radicals was established in the surface reactions. The main oxidation products, formation of nitrates, and the lignin transformation were quantified. A compound specific approach is suggested for optimization of the PCD parameters that have the most significant impact on the oxidation energy efficiency because of the different characteristics and responses of the target compound to the oxidants, as well as different admixtures that are present in the wastewater. Further studies in the method’s safety (nitration and nitrosation of organic compounds, nitrite and nitrate formation enhancement) are needed for promoting the method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The oxidation potential of pulsed corona discharge concerning aqueous impurities is limited in respect to certain refractory compounds. This may be enhanced in combination of the discharge with catalysis/photocatalysis as developed in homogeneous gas-phase reactions. The objective of the work consists of testing the hypothesis of oxidation potential enhancement in combination of the discharge with TiO2 photocatalysis applied to aqueous solutions of refractory oxalate. Meglumine acridone acetate was included for meeting the practical needs. The experimental research was undertaken into oxidation of aqueous solutions under conditions of various target pollutant concentrations, pH and the pulse repetition rate with plain electrodes and the electrodes with TiO2 attached to their surface. The results showed no positive influence of the photocatalyst, the pollutants were oxidized with the rate identical within the accuracy of measurements. The possible explanation for the observed inefficiency may include low UV irradiance, screening effect of water and generally low oxidation rate in photocatalytic reactions. Further studies might include combination of electric discharge with ozone decomposition/radical formation catalysts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT Maria Peltola Electrical status epilepticus during sleep – Continuous spikes and waves during sleep Department of Clinical Neurophysiology, University of Turku Department of Clinical Neurophysiology and Department of Pediatric Neurology, Children’s Hospital, Helsinki University Central Hospital Annales Universitatis Turkuensis, Medica-Odontologica, Turku, Finland, 2014 Background: Electrical status epilepticus during sleep (ESES) is an EEG phenomenon of frequent spikes and waves occurring in slow sleep. ESES relates to cognitive deterioration in heterogeneous childhood epilepsies. Validated methods to quantitate ESES are missing. The clinical syndrome, called epileptic encephalopathy with continuous spikes and waves during sleep (CSWS) is pharmacoresistant in half of the patients. Limited data exists on surgical treatment of CSWS. Aims and methods: The effects of surgical treatment were studied by investigating electroclinical outcomes in 13 operated patients (nine callosotomies, four resections) with pharmacoresistant CSWS and cognitive decline. Secondly, an objective paradigm was searched for assessing ESES by the semiautomatic quantification of spike index (SI) and measuring spike strength from EEG. Results: Postoperatively, cognitive deterioration was stopped in 12 (92%) patients. Three out of four patients became seizure-free after resective surgery. Callosotomy resulted in greater than 90% reduction of atypical absences in six out of eight patients. The preoperative propagation of ESES from one hemisphere to the other was associated with a good response. Semiautomatic quantification of SI was a robust method when the maximal interspike interval of three seconds was used to determine the “continuous” discharge in ten EEGs. SI of the first hour of sleep appeared representative of the whole night SI. Furthermore, the spikes’ root mean square was found to be a stable measure of spike strength when spatially integrated over multiple electrodes during steady NREM sleep. Conclusions: Patients with pharmacoresistant CSWS, based on structural etiology, may benefit from resective surgery or corpus callosotomy regarding both seizure outcome and cognitive prognosis. The semiautomated SI quantification, with proper userdefined settings and the new spatially integrated measure of spike strength, are robust and promising tools for quantifying ESES. Keywords: Electrical status epilepticus during sleep, ESES, continuous spikes and waves during sleep, CSWS, epilepsy surgery, spike index, spike strength, RMS TIIVISTELMÄ Maria Peltola Unenaikainen sähköinen status epilepticus Kliininen neurofysiologia, Turun yliopisto Kliininen neurofysiologia ja lastenneurologia, Lasten ja nuorten sairaala, Helsingin yliopistollinen keskussairaala Annales Universitatis Turkuensis, Medica-Odontologica, Turku, Suomi, 2014 Tausta: Sähköinen status epilepticus unessa (ESES) on aivosähkökäyrä (EEG)-ilmiö, jossa hidasaaltounen aikana esiintyy tiheä piikkihidasaaltopurkaus. ESES:n kvantifioimiseen ei ole olemassa validoituja menetelmiä. ESES on liitetty kognitiivisen tason laskuun ja tällöin puhutaan CSWS (continuous spikes and waves during sleep) - oireyhtymästä. CSWS ei vastaa lääkehoitoon puolella potilaista ja sen epilepsiakirurgisesta hoidosta on olemassa vain vähän tietoa. Tavoitteet ja menetelmät: Selvitimme retrospektiivisesti epilepsiakirurgian vaikusta elektrokliinisiin löydöksiin 13:lla lääkeresistenttiä CSWS-oireyhtymää sairastavalla lapsella, joilla oli rakenteellinen aivojen poikkeavuus. Toinen tavoite oli löytää objektiivinen puoliautomaattinen tapa mitata purkauksen määrää ja piikkien voimakkuutta EEG:stä. Tulokset: Kognitiivisen tason jatkuva heikentyminen loppui 12 (92 %) potilaalla leikkauksen jälkeen. Kolme neljästä resektiopotilaasta tuli kohtauksettomaksi. Kallosotomian jälkeen kuudella kahdeksasta potilaasta päivittäiset kohtaukset vähenivät yli 90 %:lla. Purkauksen leviäminen leikkausta edeltävästi vain yhdestä hemisfääristä toiseen liittyi hyvään leikkaushoitovasteeseen. Piikki-indeksi, jossa käytetään jatkuvan purkauksen määritelmänä maksimissaan kolmea sekuntia piikkien välillä, osoittautui luotettavaksi menetelmäksi ESES:n kvantifioimiseen. Useammasta elektrodista integroitu piikkien neliöllinen keskiarvo oli piikin voimakkuuden vakaa mitta häiriintymättömässä NREM-unessa. Päätelmät: Lääkehoidolle vastaamatonta CSWS:ää sairastavat potilaat, joilla on rakenteellinen aivopoikkeavuus ja yhdensuuntainen purkauksen leviämismalli, näyttävät kohtausten vähenemisen lisäksi hyötyvän epilepsiakirurgiasta kognitiivisesti. Puoliautomaattinen piikki-indeksin kvantifiointi sopivilla käyttäjäasetuksilla ja uusi spatiaalisesti integroitu piikin voimakkuuden mittari ovat stabiileja ja lupaavia ESES:n kvantitatiivisia mittareita. Avainsanat: Unenaikainen sähköinen status epilepticus, ESES, CSWS, epilepsiakirurgia, piikki-indeksi, piikin voimakkuus, neliöllinen keskiarvo

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Paper-based analytical technologies enable quantitative and rapid analysis of analytes from various application areas including healthcare, environmental monitoring and food safety. Because paper is a planar, flexible and light weight substrate, the devices can be transported and disposed easily. Diagnostic devices are especially valuable in resourcelimited environments where diagnosis as well as monitoring of therapy can be made even without electricity by using e.g. colorimetric assays. On the other hand, platforms including printed electrodes can be coupled with hand-held readers. They enable electrochemical detection with improved reliability, sensitivity and selectivity compared with colorimetric assays. In this thesis, different roll-to-roll compatible printing technologies were utilized for the fabrication of low-cost paper-based sensor platforms. The platforms intended for colorimetric assays and microfluidics were fabricated by patterning the paper substrates with hydrophobic vinyl substituted polydimethylsiloxane (PDMS) -based ink. Depending on the barrier properties of the substrate, the ink either penetrates into the paper structure creating e.g. microfluidic channel structures or remains on the surface creating a 2D analog of a microplate. The printed PDMS can be cured by a roll-ro-roll compatible infrared (IR) sintering method. The performance of these platforms was studied by printing glucose oxidase-based ink on the PDMS-free reaction areas. The subsequent application of the glucose analyte changed the colour of the white reaction area to purple with the colour density and intensity depending on the concentration of the glucose solution. Printed electrochemical cell platforms were fabricated on paper substrates with appropriate barrier properties by inkjet-printing metal nanoparticle based inks and by IR sintering them into conducting electrodes. Printed PDMS arrays were used for directing the liquid analyte onto the predetermined spots on the electrodes. Various electrochemical measurements were carried out both with the bare electrodes and electrodes functionalized with e.g. self assembled monolayers. Electrochemical glucose sensor was selected as a proof-of-concept device to demonstrate the potential of the printed electronic platforms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tässä työssä tavoitteena oli selvittää selluloosageelien soveltuvuutta superkondensaattorien elektrodimateriaaliksi. Superkondensaattoreiden elektrodit valmistetaan yleensä hyvin huokoisesta hiilimateriaalista. Näin ollen selluloosageeliin joukkoon sekoitettiin sähkönjohtavuutta parantamaan hiilimustaa. Kirjallisessa osassa keskityttiin superkondensaattorin toimintaperiaatteeseen, rakenteeseen ja yleisimmin käytössä oleviin elektrodimateriaaleihin. Yksityiskohtaisemmin paneuduttiin selluloosan käyttöön superkondensaattorien rakennemateriaalina. Kokeellisessa osassa valmistettiin erilaisia selluloosageelejä ja tämän jälkeen elektrodeja hiilimusta-selluloosageeli-seoksesta. Eri sekoitustapojen vaikutusta elektrodin sähköisiin ominaisuuksiin tarkasteltiin sekoittamalla hiilimustaa selluloosageeliin kahdella eri tavalla; korkeapainehajottajalla ja sekoittimella. Tämän lisäksi selvitettiin myös eri kuivaustapojen ja kuivauslämpötilojen vaikutusta elektrodiarkkien ominaisuuksiin. Arkkien sähköiset ominaisuudet määritettiin syklistä voltammetriaa (SV) käyttäen. Saavutetut tulokset osoittivat, että selluloosageelin valmistus on yksi kriittisimmistä kohdista elektrodimateriaalin valmistuksessa. Riittävä entsyymikäsittely vaaditaan, jotta saadaan muodostettua sopiva geeli, johon hiilimusta-partikkelit saadaan takertumaan. Hiilimustan sekoitustavalla sekä elektrodiarkin kuivauslämpötilalla ja – tavalla on myös suuresti vaikutusta elektrodin sähköisiin ominaisuuksiin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The object of the study is bacteriorhodopsin. This light-sensitive protein have been selected as perspective substance for optical and optoelectronic applications. Bacteriorhodopsin carries out pumping protons through the cell membrane. Biomolecule converts light into an electric signal when sandwiched between electrodes. These properties were utilized in this research to implement photosensors on the basis of BR layers. These properties were utilized in this research to the bR water solution. According to the absorption spectra and using Kramers – Kronig relation the extinction coefficient has been calculated, as well as the related change of the refractive index value.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hydrogen (H2) fuel cells have been considered a promising renewable energy source. The recent growth of H2 economy has required highly sensitive, micro-sized and cost-effective H2 sensor for monitoring concentrations and alerting to leakages due to the flammability and explosiveness of H2 Titanium dioxide (TiO2) made by electrochemical anodic oxidation has shown great potential as a H2 sensing material. The aim of this thesis is to develop highly sensitive H2 sensor using anodized TiO2. The sensor enables mass production and integration with microelectronics by preparing the oxide layer on suitable substrate. Morphology, elemental composition, crystal phase, electrical properties and H2 sensing properties of TiO2 nanostructures prepared on Ti foil, Si and SiO2/Si substrates were characterized. Initially, vertically oriented TiO2 nanotubes as the sensing material were obtained by anodizing Ti foil. The morphological properties of tubes could be tailored by varying the applied voltages of the anodization. The transparent oxide layer creates an interference color phenomena with white light illumination on the oxide surface. This coloration effect can be used to predict the morphological properties of the TiO2 nanostructures. The crystal phase transition from amorphous to anatase or rutile, or the mixture of anatase and rutile was observed with varying heat treatment temperatures. However, the H2 sensing properties of TiO2 nanotubes at room temperature were insufficient. H2 sensors using TiO2 nanostructures formed on Si and SiO2/Si substrates were demonstrated. In both cases, a Ti layer deposited on the substrates by a DC magnetron sputtering method was successfully anodized. A mesoporous TiO2 layer obtained on Si by anodization in an aqueous electrolyte at 5°C showed diode behavior, which was influenced by the work function difference of Pt metal electrodes and the oxide layer. The sensor enabled the detection of H2 (20-1000 ppm) at low operating temperatures (50–140°C) in ambient air. A Pd decorated tubular TiO2 layer was prepared on metal electrodes patterned SiO2/Si wafer by anodization in an organic electrolyte at 5°C. The sensor showed significantly enhanced H2 sensing properties, and detected hydrogen in the range of a few ppm with fast response/recovery time. The metal electrodes placed under the oxide layer also enhanced the mechanical tolerance of the sensor. The concept of TiO2 nanostructures on alternative substrates could be a prospect for microelectronic applications and mass production of gas sensors. The gas sensor properties can be further improved by modifying material morphologies and decorating it with catalytic materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Epilepsy is a chronic brain disorder, characterized by reoccurring seizures. Automatic sei-zure detector, incorporated into a mobile closed-loop system, can improve the quality of life for the people with epilepsy. Commercial EEG headbands, such as Emotiv Epoc, have a potential to be used as the data acquisition devices for such a system. In order to estimate that potential, epileptic EEG signals from the commercial devices were emulated in this work based on the EEG data from a clinical dataset. The emulated characteristics include the referencing scheme, the set of electrodes used, the sampling rate, the sample resolution and the noise level. Performance of the existing algorithm for detection of epileptic seizures, developed in the context of clinical data, has been evaluated on the emulated commercial data. The results show, that after the transformation of the data towards the characteristics of Emotiv Epoc, the detection capabilities of the algorithm are mostly preserved. The ranges of acceptable changes in the signal parameters are also estimated.