102 resultados para Discharge transfer coefficient


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of Reynolds number variation in a vertical double pipe counterflow heat exchanger due to the changes in viscosity can cause the change in flow regime, for instance, when heats up and cools down, it can convert from turbulent to laminar or inversely, that can have significant effect on heat transfer coefficient and pressure drop. Mainly, the range of transition phase has been studied in this study with the investigation of silica nanofluid dispersed in water in three different concentrations. The results have been compared with distilled water sample and showed a remarkable raise in heat transfer coefficient while pressure drop has been increased respectively, as well. Although pumping power has to go up at the same time and it is a drawback, heat transfer efficiency grows for diluted samples. On the other hand, for the most concentrated sample, effect of pressure drop dominates which leads to decline in the overall efficiency.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The studies of flow phenomena, heat and mass transfer in microchannel reactors are beneficial to estimate and evaluate the ability of microchannel reactors to be operated for a given process reaction such as Fischer-Tropsch synthesis. The flow phenomena, for example, the flow regimes and flow patterns in microchannel reactors for both single phase and multiphase flow are affected by the configuration of the flow channel. The reviews of the previous works about the analysis of related parameters that affect the flow phenomena are shown in this report. In order to predict the phenomena of Fischer-Tropsch synthesis in microchannel reactors, the 3-dimensional computational fluid dynamic simulation with commercial software package FLUENT was done to study the flow phenomena and heat transfer for gas phase Fischer-Tropsch products flow in rectangular microchannel with hydraulic diameter 500 ¿m and length 15 cm. Numerical solution with slip boundary condition was used in the simulation and the flowphenomena and heat transfer were determined.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Uusi EPR-reaktorikonsepti on suunniteltu selviytymään tapauksista, joissa reaktorinsydän sulaa ja sula puhkaisee paineastian. Suojarakennuksen sisälle on suunniteltu alue, jolle sula passiivisesti kerätään, pidätetään ja jäähdytetään. Alueelle laaditaan valurautaelementeistä ns.sydänsieppari, joka tulvitetaan vedellä. Sydänsulan tuottama jälkilämpö siirtyyveteen, mistä se poistetaan suojarakennuksen jälkilämmönpoistojärjestelmän kautta. Suuri osa lämmöstä poistuu sydänsulasta sen yläpuolella olevaan veteen, mutta lämmönsiirron tehostamiseksi myös sydänsiepparin alapuolelle on sijoitettu vedellä täytettävät jäähdytyskanavat. Jotta sydänsiepparin toiminta voitaisiin todentaa, on Lappeenrannan Teknillisellä Yliopistolla rakennettu Volley-koelaitteisto tätä tarkoitusta varten. Koelaitteisto koostuu kahdesta täysimittaisesta valuraudasta tehdystä jäähdytyskanavasta. Sydänsulan tuottamaa jälkilämpöä simuloidaan koelaitteistossa sähkövastuksilla. Tässä työssä kuvataan simulaatioiden suorittaminen ja vertaillaan saatuja arvoja mittaustuloksiin. Työ keskittyy sydänsiepparista jäähdytyskanaviin tapahtuvan lämmönsiirron teoriaan jamekanismeihin. Työssä esitetään kolme erilaista korrelaatiota lämmönsiirtokertoimille allaskiehumisen tapauksessa. Nämä korrelaatiot soveltuvat erityisesti tapauksiin, joissa vain muutamia mittausparametreja on tiedossa. Työn toinen osa onVolley 04 -kokeiden simulointi. Ensin käytettyä simulointitapaa on kelpoistettuvertaamalla tuloksia Volley 04 ja 05 -kokeisiin, joissa koetta voitiin jatkaa tasapainotilaan ja joissa jäähdytteen käyttäytyminen jäähdytyskanavassa on tallennettu myös videokameralla. Näiden simulaatioiden tulokset ovat hyvin samanlaisiakuin mittaustulokset. Korkeammilla lämmitystehoilla kokeissa esiintyi vesi-iskuja, jotka rikkoivat videoinnin mahdollistavia ikkunoita. Tämän johdosta osassa Volley 04 -kokeita ikkunat peitettiin metallilevyillä. Joitakin kokeita jouduttiin keskeyttämään laitteiston suurten lämpöjännitysten johdosta. Tällaisten testien simulaatiot eivät ole yksinkertaisia suorittaa. Veden pinnan korkeudesta ei ole visuaalista havaintoa. Myöskään jäähdytteen tasapainotilanlämpötiloista ei ole tarkkaa tietoa, mutta joitakin oletuksia voidaan tehdä samoilla parametreilla tehtyjen Volley 05 -kokeiden perusteella. Mittaustulokset Volley 04 ja 05 -kokeista, jotka on videoitu ja voitu ajaa tasapainotilaan saakka, antoivat simulaatioiden kanssa hyvin samankaltaisia lämpötilojen arvoja. Keskeytettyjen kokeiden ekstrapolointi tasapainotilaan ei onnistunut kovin hyvin. Kokeet jouduttiin keskeyttämään niin paljon ennen termohydraulista tasapainoa, ettei tasapainotilan reunaehtoja voitu ennustaa. Videonauhoituksen puuttuessa ei veden pinnan korkeudesta saatu lisätietoa. Tuloksista voidaan lähinnä esittää arvioita siitä, mitä suuruusluokkaa mittapisteiden lämpötilat tulevat olemaan. Nämä lämpötilat ovat kuitenkin selvästi alle sydänsiepparissa käytettävän valuraudan sulamislämpötilan. Joten simulaatioiden perusteella voidaan sanoa, etteivät jäähdytyskanavien rakenteet sula, mikäli niissä on pienikin jäähdytevirtaus, eikä useampia kuin muutama vierekkäinen kanava ole täysin kuivana.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work deals with the cooling of high-speed electric machines, such as motors and generators, through an air gap. It consists of numerical and experimental modelling of gas flow and heat transfer in an annular channel. Velocity and temperature profiles are modelled in the air gap of a high-speed testmachine. Local and mean heat transfer coefficients and total friction coefficients are attained for a smooth rotor-stator combination at a large velocity range. The aim is to solve the heat transfer numerically and experimentally. The FINFLO software, developed at Helsinki University of Technology, has been used in the flow solution, and the commercial IGG and Field view programs for the grid generation and post processing. The annular channel is discretized as a sector mesh. Calculation is performed with constant mass flow rate on six rotational speeds. The effect of turbulence is calculated using three turbulence models. The friction coefficient and velocity factor are attained via total friction power. The first part of experimental section consists of finding the proper sensors and calibrating them in a straight pipe. After preliminary tests, a RdF-sensor is glued on the walls of stator and rotor surfaces. Telemetry is needed to be able to measure the heat transfer coefficients at the rotor. The mean heat transfer coefficients are measured in a test machine on four cooling air mass flow rates at a wide Couette Reynolds number range. The calculated values concerning the friction and heat transfer coefficients are compared with measured and semi-empirical data. Heat is transferred from the hotter stator and rotor surfaces to the coolerair flow in the air gap, not from the rotor to the stator via the air gap, althought the stator temperature is lower than the rotor temperature. The calculatedfriction coefficients fits well with the semi-empirical equations and precedingmeasurements. On constant mass flow rate the rotor heat transfer coefficient attains a saturation point at a higher rotational speed, while the heat transfer coefficient of the stator grows uniformly. The magnitudes of the heat transfer coefficients are almost constant with different turbulence models. The calibrationof sensors in a straight pipe is only an advisory step in the selection process. Telemetry is tested in the pipe conditions and compared to the same measurements with a plain sensor. The magnitudes of the measured data and the data from the semi-empirical equation are higher for the heat transfer coefficients than thenumerical data considered on the velocity range. Friction and heat transfer coefficients are presented in a large velocity range in the report. The goals are reached acceptably using numerical and experimental research. The next challenge is to achieve results for grooved stator-rotor combinations. The work contains also results for an air gap with a grooved stator with 36 slots. The velocity field by the numerical method does not match in every respect the estimated flow mode. The absence of secondary Taylor vortices is evident when using time averagednumerical simulation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Gas-liquid mass transfer is an important issue in the design and operation of many chemical unit operations. Despite its importance, the evaluation of gas-liquid mass transfer is not straightforward due to the complex nature of the phenomena involved. In this thesis gas-liquid mass transfer was evaluated in three different gas-liquid reactors in a traditional way by measuring the volumetric mass transfer coefficient (kLa). The studied reactors were a bubble column with a T-junction two-phase nozzle for gas dispersion, an industrial scale bubble column reactor for the oxidation of tetrahydroanthrahydroquinone and a concurrent downflow structured bed.The main drawback of this approach is that the obtained correlations give only the average volumetric mass transfer coefficient, which is dependent on average conditions. Moreover, the obtained correlations are valid only for the studied geometry and for the chemical system used in the measurements. In principle, a more fundamental approach is to estimate the interfacial area available for mass transfer from bubble size distributions obtained by solution of population balance equations. This approach has been used in this thesis by developing a population balance model for a bubble column together with phenomenological models for bubble breakage and coalescence. The parameters of the bubble breakage rate and coalescence rate models were estimated by comparing the measured and calculated bubble sizes. The coalescence models always have at least one experimental parameter. This is because the bubble coalescence depends on liquid composition in a way which is difficult to evaluate using known physical properties. The coalescence properties of some model solutions were evaluated by measuring the time that a bubble rests at the free liquid-gas interface before coalescing (the so-calledpersistence time or rest time). The measured persistence times range from 10 msup to 15 s depending on the solution. The coalescence was never found to be instantaneous. The bubble oscillates up and down at the interface at least a coupleof times before coalescence takes place. The measured persistence times were compared to coalescence times obtained by parameter fitting using measured bubble size distributions in a bubble column and a bubble column population balance model. For short persistence times, the persistence and coalescence times are in good agreement. For longer persistence times, however, the persistence times are at least an order of magnitude longer than the corresponding coalescence times from parameter fitting. This discrepancy may be attributed to the uncertainties concerning the estimation of energy dissipation rates, collision rates and mechanisms and contact times of the bubbles.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This dissertation is based on four articles dealing with modeling of ozonation. The literature part of this considers some models for hydrodynamics in bubble column simulation. A literature review of methods for obtaining mass transfer coefficients is presented. The methods presented to obtain mass transfer are general models and can be applied to any gas-liquid system. Ozonation reaction models and methods for obtaining stoichiometric coefficients and reaction rate coefficients for ozonation reactions are discussed in the final section of the literature part. In the first article, ozone gas-liquid mass transfer into water in a bubble column was investigated for different pH values. A more general method for estimation of mass transfer and Henry’s coefficient was developed from the Beltrán method. The ozone volumetric mass transfer coefficient and the Henry’s coefficient were determined simultaneously by parameter estimation using a nonlinear optimization method. A minor dependence of the Henry’s law constant on pH was detected at the pH range 4 - 9. In the second article, a new method using the axial dispersion model for estimation of ozone self-decomposition kinetics in a semi-batch bubble column reactor was developed. The reaction rate coefficients for literature equations of ozone decomposition and the gas phase dispersion coefficient were estimated and compared with the literature data. The reaction order in the pH range 7-10 with respect to ozone 1.12 and 0.51 the hydroxyl ion were obtained, which is in good agreement with literature. The model parameters were determined by parameter estimation using a nonlinear optimization method. Sensitivity analysis was conducted using object function method to obtain information about the reliability and identifiability of the estimated parameters. In the third article, the reaction rate coefficients and the stoichiometric coefficients in the reaction of ozone with the model component p-nitrophenol were estimated at low pH of water using nonlinear optimization. A novel method for estimation of multireaction model parameters in ozonation was developed. In this method the concentration of unknown intermediate compounds is presented as a residual COD (chemical oxygen demand) calculated from the measured COD and the theoretical COD for the known species. The decomposition rate of p-nitrophenol on the pathway producing hydroquinone was found to be about two times faster than the p-nitrophenol decomposition rate on the pathway producing 4- nitrocatechol. In the fourth article, the reaction kinetics of p-nitrophenol ozonation was studied in a bubble column at pH 2. Using the new reaction kinetic model presented in the previous article, the reaction kinetic parameters, rate coefficients, and stoichiometric coefficients as well as the mass transfer coefficient were estimated with nonlinear estimation. The decomposition rate of pnitrophenol was found to be equal both on the pathway producing hydroquinone and on the path way producing 4-nitrocathecol. Comparison of the rate coefficients with the case at initial pH 5 indicates that the p-nitrophenol degradation producing 4- nitrocathecol is more selective towards molecular ozone than the reaction producing hydroquinone. The identifiability and reliability of the estimated parameters were analyzed with the Marcov chain Monte Carlo (MCMC) method. @All rights reserved. No part of the publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior permission of the author.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study illustrates the different types of plate heat exchangers that are commonly used in various domestic and industrial applications. The main purpose of this paper was to devise a methodology that is capable of calculating optimum number of plates in the design of a plate heat exchanger. To obtain the appropriate number of plates, typically several iterations must be made before a final acceptable design is completed, since plate amount depends on many factors such as, flow velocities, physical properties of the streams, flow channel geometry, allowable pressure drop, plate dimensions, and the gap between the plates. The methodology presented here can be used as a general guide for designing a plate heat exchanger. To investigate the effects of relevant parameters on the thermal-hydraulic design of a plate heat exchanger, several experiments were carried out for single-phase and counter flow arrangement with two brazed plate heat exchangers by varying the flow rates and the inlet temperatures of the fluid streams. The actual heat transfer coefficients obtained based on the experiment were nearly close to the calculated values and to improve the design, a correction factor was introduced. Besides, the effect of flow channel velocity on the pressure drop inside the unit is presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Työn tavoitteena oli tutkia aaltomaisen profiloinnin vaikutusta suorien jäähdytyskanavien lämmönsiirtoon ja painehäviöön. Erilaisia profiileja oli kymmenen kappaletta ja ne olivat 5mm leveitä ja 30cm pitkiä kukin. Ne laskettiin kolmeulotteisina tapauksina FINFLO-virtausratkaisijalla kolmella eri Reynoldsin luvulla, jotka vastasivat laminaarista, osittain turbulenttista ja lähes kokonaan turbulenttista virtausta. Lämmönsiirtoaine oli kuiva +30°C ilma ja profiloinnin toteutustapa oli toisiaan sivuavat ympyräkaaret kolmella erilaisella säteen arvolla ja kolmella erilaisella aallonpituuden arvolla. Lisäksi laskettiin saman levyisen tasokanavan arvot jokaisella Reynoldsin luvulla kaksiulotteisina tapauksina. Näitä profiloimattomia kanavia pidettiin referenssitapauksina. Tuloksena havaittiin että profiloimalla saadaan yksiselitteisesti suurempi lämpöteho ulos samasta tilavuudesta. Lämmönsiirtokerroin kasvaa profiloinnin avulla parhaimmillaan n. 20% käytetystä turbulenssimallista tai lämmönsiirtokertoimen määritelmästä riippumatta. Painehäviö kasvaa myös aina, mutta kitkakerroin voi hieman pienentyä. Profiilin varsinaisena hyvyyskriteerinä pidettiin lämmönsiirtokertoimen ja kitkakertoimen suhdetta h/f. Se osoittautui riippuvaksi Reynoldsin luvusta ja turbulenssimallista; ASM ja Chien k-έ -mallit ennustavat transitioetäisyyden eri tavalla. Laminaarisilla virtauksilla h/f :n vaihtelu oli vähäistä; suhde vaihteli vain ±5% eri profiilien kesken. ASM-mallilla havaittiin sekundääripyörteilyä, ehkä siksi että se mallintaa anisotrooppisen turbulenssin. Chien k-έ malli ennusti suuremman ja aikaisemmin alkavan turbulenttisuuden kuin ASM. Lisäksi havaittiin mm. että tietyillä profiileilla muodostuu kanavan kapeimpaan kohtaan selvä virtausnopeuden paikallinen minimi seinämän läheisyyden takia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Työssä tutkittiin synteesikaasun komponenttien: hiilimonoksidin, vedyn ja hiilidioksidin liukoisuutta ja aineensiirtonopeutta fermentointiliuokseen. Kirjallisuusosassa käsitellään kaasujen liukoisuuksiin ja kaasu-nesteaineensiirtoon vaikuttavia tekijöitä ja esitellään korrelaatioita, jotka on kehitetty volumetrisen aineensiirtokertoimen ennustamiseen sekoitetussa fermentorissa. Kirjallisuus-osassa esitetään myös synteesikaasun komponenttien liukoisuudet veteen, etanoliin ja etikkahappoon 37 ºC lämpötilassa ja esitellään Flowbat-simulointiohjelman MHV2-mallin käyttöä kaasu-neste tasapainojen mallin-nuksessa. Työn kokeellisessa osassa tutkittiin synteesikaasun komponenttien liukoisuuksia veteen ja kasvatusalustaan sekä kehitettiin mittausmenetelmä kaasu-neste tasapainojen mittaukseen. Tasapainomittauksissa tutkittiin etanolin ja etikkahapon konsentraatioiden vaikutusta synteesikaasun liukoisuuteen. Lisäksi mallinnettiin kaasu-neste tasapainoja monikomponenttisysteemeissä MHV2-mallin avulla. Kokeellisen osan aineensiirtomittauksissa tutkittiin sekoitusnopeuden ja kaasun volumetrisen syöttönopeuden vaikutusta hiilimonoksidin ja vedyn volumetriseen aineensiirtokertoimeen kLa kahden litran tilavuuksisessa laboratoriofermentorissa. Mittaustulosten perusteella kasvatusalustan komponentit vaikuttavat merkittävästi hiilidioksidin liukoisuuteen. Lisäys etanolin ja etikkahapon konsentraatioissa parantaa hiilimonoksidin liukoisuutta kasvatusalustaan. Kaasun volumetrinen syöttönopeus ja sekoitusnopeus vaikuttavat voimakkaasti volumetrisen aineensiirtokertoimen arvoon. Tutkitussa systeemissä korkein teoreettinen solutiheys, joka voitiin saavuttaa suurimmalla hiilimonoksidin aineensiirto-nopeudella, oli 3 g/L. Tämä on kaksinkertainen verrattuna aiemmissa VTT:n kokeissa saavutettuihin solutiheyksiin.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Työssä tutkittiin, mikä on kustannustehokkain tapa lisätä ilmastuskapasiteettia ja selvitettiin, saostaako vesilaitokselta flotaatioaltaasta poistettava ferrisulfaattisakka jäteveden fosforia esiselkeyttimessä. Työssä määritettiin teoreettinen hapentarve ilmastusaltaassa maksimikuormituksen aikana ja hapensiirtonopeus jäteveteen olemassa olevalla laitteistolla. Hapensiirtonopeuden funktion korjauskertoimet  ja  sekä kokonaishapensiirtokerroin määritettiin laboratorio-olosuhteissa. Lisäksi laskettiin kuinka paljon nykyisten ilmastimien kautta saadaan happea jäteveteen liukenemaan ja verrattiin tätä lukua teoreettiseen hapentarpeeseen. Jälkimmäistä menettelytapaa käyttäen arvioitiin lisähapen tarve. Tulokseksi saatiin, että maksimi BOD-kuormituksen aikana happea tarvitsee saada jäteveteen liuotettua 5200 m³/d lisää. Ilmastuskapasiteetin lisäyksen kustannuslaskelmassa verrattiin neljää vaihtoehtoa: puhdasta happea liuotettuna happimattojen kautta tai OKI-ilmastimen kautta, onsite-happilaitoksen puhdasta happea liuotettuna OKI-ilmastimen kautta tai ilman happea liuotettuna jäteveteen EDI-ilmastimien kautta. Laskelmat osoittivat uusien EDI-ilmastimien hankinnan olevan edullisin vaihtoehto pitkällä aikavälillä. Vaikka EDI-ilmastimien investointikustannukset ovat korkeat, tulevat ne käyttökustannuksiltaan kaikkein edullisimmaksi. Vesilaitokselta tulevan rautasuolasakan fosforia saostavaa vaikutusta tutkittiin laboratoriossa astiakokein. Näytteet otettiin vesilaitokselta jätevesilaitokselle menevästä rautasuolasakasta sekä esiselkeyttimen kirkasteesta. Näitä eri suhteissa keskenään sekoittamalla saatiin selville, että rautasuolasakka ja sakan mukana tuleva reagoimaton rautasuola saostavat liukoista ja kokonaisfosforia esiselkeytyksessä.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tulisijojen tekniikkaan kohdistuu yhä kovempia vaatimuksia sekä kuluttajien että myös erityisesti viranomaismääräysten suunnalta. Tämän työn tarkoituksena on osaltaan luoda pohjaa näiden vaatimusten täyttämiselle. Työn tavoitteena oli määrittää lämmönsiirtokerroin tyypillisen vuolukivirakenteisen tulisijan poskikanavassa savukaasun ja kanavan seinämän välillä. Työ koostuu mittauslaitteen suunnittelusta, käytännön mittauksista ja mittaustulosten analysoinnista teoriaan verrattuina. Työ pohjautuu käytännön mittauksiin kahdella koeuunilla. Mittaukset kohdistuivat uunien poskikanavissa ja poskikanavan seinämissä tapahtuviin lämpötilamuutoksiin. Toisessa koeuunissa mitattiin myös poskikanavan savukaasun lämpötilajakauma. Mittauksilla saatua sekä teoreettisesti määritettyä lämpötilajakaumaa verrattiin toisiinsa. Lämmönsiirtokertoimet määritettiin lämpötilojen ja savukaasun massavirran perusteella. Tuloksena saatiin paikalliset sekä yleispätevät lämmönsiirtokertoimet savukaasun lämpötilan funktiona.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis is focused on process intensification. Several significant problems and applications of this theme are covered. Process intensification is nowadays one of the most popular trends in chemical engineering and attempts have been made to develop a general, systematic methodology for intensification. This seems, however, to be very difficult, because intensified processes are often based on creativity and novel ideas. Monolith reactors and microreactors are successful examples of process intensification. They are usually multichannel devices in which a proper feed technique is important for creating even fluid distribution into the channels. Two different feed techniques were tested for monoliths. In the first technique a shower method was implemented by means of perforated plates. The second technique was a dispersion method using static mixers. Both techniques offered stable operation and uniform fluid distribution. The dispersion method enabled a wider operational range in terms of liquid superficial velocity. Using dispersion method, a volumetric gas-liquid mass transfer coefficient of 2 s-1 was reached. Flow patterns play a significant role in terms of the mixing performance of micromixers. Although the geometry of a T-mixer is simple, channel configurations and dimensions had a clear effect on mixing efficiency. The flow in the microchannel was laminar, but the formation of vortices promoted mixing in micro T-mixers. The generation of vortices was dependent on the channel dimensions, configurations and flow rate. Microreactors offer a high ratio of surface area to volume. Surface forces and interactions between fluids and surfaces are, therefore, often dominant factors. In certain cases, the interactions can be effectively utilised. Different wetting properties of solid materials (PTFE and stainless steel) were applied in the separation of immiscible liquid phases. A micro-scale plate coalescer with hydrophilic and hydrophobic surfaces was used for the continuous separation of organic and aqueous phases. Complete phase separation occurred in less than 20 seconds, whereas the separation time by settling exceeded 30 min. Fluid flows can be also intensified in suitable conditions. By adding certain additives into turbulent fluid flow, it was possible to reduce friction (drag) by 40 %. Drag reduction decreases frictional pressure drop in pipelines which leads to remarkable energy savings and decreases the size or number of pumping facilities required, e.g., in oil transport pipes. Process intensification enables operation often under more optimal conditions. The consequent cost savings from reduced use of raw materials and reduced waste lead to greater economic benefits in processing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Soodakattilan sulakeon epästationaarinen käyttäytyminen sekä keon pitkä jäähtymisaika alasajon jälkeen ovat aiheuttaneet ongelmia kattilan taloudellisessa käytettävyydessä. Keon käyttäytymisestä on luotu CFD-malleja, joiden tavoitteena on havainnollistaa keon lämpötilajakaumaa ja rakennetta. Mallien ongelmana on se, että niissä huomioidaan vain keon aktiivinen pintakerros. Keon sisäosan rakennetta ja siinä tapahtuvia prosesseja ei toistaiseksi tunneta kunnolla luotettavan, koko keon kattavan mallin luomiseen. Tässä työssä tutkittiin sulakeon käytön aikana havaittuja muutosilmiöitä, jotka vaikuttavat keon rakenteeseen ja ominaisuuksiin sekä tutkittiin ilmiöiden taustalla olevia tekijöitä. Näitä tekijöitä ovat keon sisässä tapahtuvat kemialliset ja fyysiset prosessit, jotka aiheuttavat muutoksia niin lämpöteknisesti kuin fyysisesti sekä ulkoapäin tulevat tekijät, jotka aiheutuvat ajotilanteiden seurauksena tapahtuvista muutoksista. Työn kokeellisena osana luotiin sulakeon jäähtymismalli käyttäen 1-dimensionaalista ADL-mallia. Mallin pohjana käytettiin StoraEnso Oy:ltä Oulun soodakattilan sulakeosta saatua mittausraporttia. ADL-mallin avulla luotiin keon jäähtymiskäyrät lämpötilan ja syvyyden funktiona. Saadut käyrät täsmäsivät hyvin mittausraportin tuloksiin. Mallin avulla keolle saatiin muodostettua energiatase, jonka tuloksena keosta 12 tunnin aikana poistuva lämpövirta pinnalla oli noin 9.8kW/m2 ja pinnan lämmönsiirtokerroin 58.3W/m²°C. Pohjan poistuvaksi lämpövirraksi saatiin 14.1kW/m2 ja lämmönsiirtokertoimeksi 75.4W/m²°C. Termiseksi diffuusiokertoimeksi saatiin 3.9•10-7m²/s.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of the thesis was to examine the possibilities in designing better performing nozzles for the heatset drying oven in Forest Pilot Center. To achieve the objective, two predesigned nozzle types along with the replicas of the current nozzles in the heatset drying oven were tested on a pilot-scale dryer. During the runnability trials, the pilot dryer was installed between the last printing unit and the drying oven. The two sets of predesigned nozzles were consecutively installed in the dryer. Four web tension values and four different impingement air velocities were used and the web behavior during the trial points was evaluated and recorded. The runnability in all trial conditions was adequate or even good. During the heat transfer trials, each nozzle type was tested on at least two different nozzle-to-surface distances and four different impingement air velocities. In a test situation, an aluminum plate fitted with thermocouples was set below a nozzle and the temperature measurement of each block was logged. From the measurements, a heat transfer coefficient profile for the nozzle was calculated. The performance of each nozzle type in tested conditions could now be rated and compared. The results verified that the predesigned simpler nozzles were better than the replicas. For runnability reasons, there were rows of inclined orifices on the leading and trailing edges of the current nozzles. They were believed to deteriorate the overall performance of the nozzle, and trials were conducted to test this hypothesis. The perpendicular orifices and inclined orifices of a replica nozzle were consecutively taped shut and the performance of the modified nozzles was measured as before, and then compared to the performance of the whole nozzle. It was found out, that after a certain nozzle-to-surface distance the jets from the two nozzles would collide, which deteriorates the heat transfer.