5 resultados para Reduced Gases

em Iowa Publications Online (IPO) - State Library, State of Iowa (Iowa), United States


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This document provides language that can be used by an Owner-Agency to develop materials and construction specifications with the objective of reducing tire/pavement noise. While the practices described herein are largely prescriptive, they have been demonstrated to increase the likelihood of constructing a durable, quieter concrete surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This document provides language that can be used by an Owner-Agency to develop materials and construction specifications with the objective of reducing tire/pavement noise. While the practices described herein are largely prescriptive, they have been demonstrated to increase the likelihood of constructing a durable, quieter concrete surface. Guidance is provided herein for texturing the concrete surface since texture geometry has a paramount effect on tire/pavement noise. Guidance for curing is also provided to improve strength and durability of the surface mortar, and thus to improve texture durability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This document provides language that can be used by an Owner-Agency to develop materials and construction specifications with the objective of reducing tire/pavement noise. While the practices described herein are largely prescriptive, they have been demonstrated to increase the likelihood of constructing a durable, quieter concrete surface. Guidance is provided herein for texturing the concrete surface since texture geometry has a paramount effect on tire/pavement noise. Guidance for curing is also provided to improve strength and durability of the surface mortar, and thus to improve texture durability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fly ash was used to replace 15% of the cement in C3WR and C6WR concrete paving mixes containing ASTM C494 Type A water reducin9 admixtures. Two Class C ashes and one Class F ash from Iowa approved sources were examined in each mix. When Class C ashes were used they were substituted on the basis of 1 pound of ash added for each pound of cement deleted. When Class F was used it was substituted on the basis of 1.25 pounds of ash added for each pound of cement deleted. Compressive strengths of the water reduced mixes, with and without fly ash, were determined at 7, 28, and 56 days of age. In every case except one the mixes containing the fly ash exhibited higher strengths than the same concrete mix without the fly ash. An excellent correlation existed between the C3WR and C6WR mixes both with and without fly ash substitutions. The freeze-thaw durability of the concrete studied was not affected by presence or absence of fly ash. The data gathered suggests that the present Class C water reduced concrete paving mixes can be modified to allow the substitution of 15% of the cement with an approved fly ash.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first phase of the study of intersection lighting and accidents conducted using data from 1964 through 1971 yielded the conclusion that the installation of intersection lighting reduced the nighttime accident frequency by 52%. With this conclusion, this project (the second phase), was initiated to determine the relative benefit of a higher level of lighting as opposed to minimum lighting. Twenty pairs of intersections with similar geometrics were selected. Some lights were turned out at one intersection of each pair to produce a lighting level differential. Based on the results of this research, the lighting level of lighted rural at-grade intersections does not have a significant effect on the accident frequency. At the nineteen "reduced lighting" intersections, the number of lighted luminaires was reduced from 101 to 46 with a corresponding reduction in energy consumption of over 100,000 Kilowatt hours per year. This energy conservation measure could reduce consumption by an estimated 1,000,000 Kilowatt hours per year if initiated on more than 200 earlier primary, rural installations.