2 resultados para Cartões CRC
em Iowa Publications Online (IPO) - State Library, State of Iowa (Iowa), United States
Resumo:
Highlights: * Whether you’re looking for a job or seeking to bolster your credentials, earning a Career Readiness Certificate (CRC) gives you proof of your job skills....pg. 2 * Michelle Frey was laid off in 2003. She worked with the WIA program to research and look into careers that would suit her....pg. 2 * Currently, over 450 participants (laborers) are involved in the Emergency Public Jobs (EMJ) program ....pg. 3 * Established in 1999, the first two New Iowan Centers were opened in Muscatine and Sioux City, the eastern and western doors to Iowa....pg. 3 * We appreciate the feedback we get from our customers. Read a few noteworthy comments we’ve received....pg. 4
Resumo:
The Greene County, Iowa overlay project, completed in October 1973, was inspected on October 16 & 17, 1978 After five years of service The 33 fibrous concrete sections, four CRCP sections, two mesh reinforced and two plain concrete sections with doweled reinforcement were rated relative to each other on a scale of 0 t o 100. The rating was conducted by the original members of the Project Planning Committee, Iowa DOT, Iowa Counties, Federal Highway Administration, University of Illinois and industry representatives . In all , there were 23 representatives who rated this project . The 23 values were then averaged to provide a final rating number for each section. The highest panel rating (90) was assigned to the 5-inch thick , deformed barre in forced PCC sections ; an 86t o a 3-inch thick , 160 lbs. of fiber and 600 lbs . of cement on a partial bonded surface ; an 84 to the 4-inch CRC with elastic joints (bonded) and an 84 to a 4-inch mesh reinforce section. One of the major factors influencing performance appears t o be the thickness. In the fibrous concrete overlay, The greatest influences appears t o be the fiber content. Overlay Sections containing 160 1b/yd3 of Fiber are, in almost all cases , outperforming those c o n t a i n i n g 60 or 100. It is obvious at This time meth at the 3-inch thick fibrous concrete overlays are, in general, out performing the 2-inch thick sections. The performance of the fibrous concrete the overlay appears to be favorably influenced by: (1) The use of higher a spectra fiber (0.025 x 2.5 i n c h e s ) v e r s u s (0.010 x 0.022 x 1.0 inches) (2) The use of a lower cement c o n t e n t ( 600 versus 750 1b/yd3) However, The set less well defined and the improvements in overlay performance attributed to high aspect ratio fibers and low cement contents.