51 resultados para joint terminal attack controller


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Install new tile system to eliminate the use of 20 agricultural drainage wells (ADW) that have been ruled by EPA to be "vunerable to spills from manure lagoons, direct discharges from septic tanks and accidental releases of materails used in farming". The project includes a tile system that will provide an outlet for all the tile connected to the ADWs and close all 20 ADWs in the drainage district. The pipe ranges in size from 42" to 8" in diameter and approximately 48,000 lineal feet to be installed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eighty-Sixth General Assembly Joint Rules of the House and Senate (House Concurrent Resolution 6), House adopted 2-3-2015, Senate adopted 2-4-2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eighty-Sixth General Assembly Joint Rules Governing Lobbyists (House Concurrent Resolution 7) House Adopted 2-3-2015, Senate Adopted 2-4-2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Th e Warrior Ready is an offi cial publication authorized under the provisions of AR 360-1. It is published electronically by the Iowa National Guard State Public Aff airs Offi ce on a monthly basis. News and opinions expressed in this publication are not necessarily those of the Adjutant General of Iowa, the National Guard, or the Department of Defense.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integral abutment bridges are constructed without an expansion joint in the superstructure of the bridge; therefore, the bridge girders, deck, abutment diaphragms, and abutments are monolithically constructed. The abutment piles in an integral abutment bridge are vertically orientated, and they are embedded into the pile cap. When this type of a bridge experiences thermal expansion or contraction, horizontal displacements are induced at the top of the abutment piles. The flexibility of the abutment piles eliminates the need to provide an expansion joint at the inside face to the abutments: Integral abutment bridge construction has been used in Iowa and other states for many years. This research is evaluating the performance of integral abutment bridges by investigating thermally induced displacements, strains, and temperatures in two Iowa bridges. Each bridge has a skewed alignment, contains five prestressed concrete girders that support a 30-ft wide roadway for three spans, and involves a water crossing. The bridges will be monitored for about two years. For each bridge, an instrumentation package includes measurement devices and hardware and software support systems. The measurement devices are displacement transducers, strain gages, and thermocouples. The hardware and software systems include a data-logger; multiplexers; directline telephone service and computer terminal modem; direct-line electrical power; lap-top computer; and an assortment of computer programs for monitoring, transmitting, and management of the data. Instrumentation has been installed on a bridge located in Guthrie County, and similar instrumentation is currently being installed on a bridge located in Story County. Preliminary test results for the bridge located in Guthrie County have revealed that temperature changes of the bridge deck and girders induce both longitudinal and transverse displacements of the abutments and significant flexural strains in the abutment piles. For an average temperature range of 73° F for the superstructure concrete in the bridge located in Guthrie County, the change in the bridge length was about 1 118 in. and the maximum, strong-axis, flexural-strain range for one of the abutment piles was about 400 micro-strains, which corresponds to a stress range of about 11,600 psi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bridge expansion joints, if not properly designed, constructed, and maintained, often lead to the deterioration of critical substructure elements. Strip seal expansion joints consisting of a steel extrusion and neoprene gland are one type of expansion joint and are commonly used by the Iowa Department of Transportation (DOT). Strip seal expansion joints are susceptible to tears and pull outs that allow water, chlorides, and debris to infiltrate the joint, and subsequently the bearings below. One area of the strip seal that is particularly problematic is where it terminates at the interface between the deck and the barrier rail. The Iowa DOT has noted that the initial construction quality of the current strip seal termination detail is not satisfactory, nor ideal, and a need exists for re-evaluation and possibly re-design of this detail. Desirable qualities of a strip seal termination detail provide a seal that is simple and fast to construct, facilitate quick gland removal and installation, and provide a reliable, durable barrier to prevent chloride-contaminated water from reaching the substructure. To meet the objectives of this research project, several strip seal termination details were evaluated in the laboratory. Alternate termination details may not only function better than the current Iowa DOT standard, but are also less complicated to construct, facilitating better quality control. However, uncertainties still exist regarding the long-term effects of using straight-through details, with or without the dogleg, that could not be answered in the laboratory in the short time frame of the research project.