77 resultados para air surveillance
Resumo:
Senate File 2355 Sec. 19 (Iowa Code §328.13) created a commercial air service retention and expansion committee within the aviation office of the department of transportation. The membership of the committee consisted of the director or the director’s designee; the managers of each airport in Iowa with commercial air service; two members of the senate, one appointed by the majority leader of the senate and one appointed by the minority leader of the senate; and two members of the house of representatives, one appointed by the speaker of the house and one appointed by the minority leader of the house. The committee was to develop a plan by December 31, 2014 for the retention and expansion of passenger air service in Iowa. The committee is to meet as the committee deems necessary to assess progress in implementing the plan and, if necessary, to update the plan.
Resumo:
The stability of air bubbles in fresh concrete can have a profound influence of the potential durability of the system, because excessive losses during placement and consolidation can compromise the ability of the mixture to resist freezing and thawing. The stability of air void systems developed by some air entraining admixtures (AEAs) could be affected by the presence of some polycarboxylate-based water reducing admixtures (WRAs). The foam drainage test provides a means of measuring the potential stability of air bubbles in a paste. A barrier to acceptance of the test was that there was little investigation of the correlation with field performance. The work reported here was a limited exercise seeking to observe the stability of a range of currently available AEA/WRA combinations in the foam drainage test; then, to take the best and the worst and observe their stabilities on concrete mixtures in the lab. Based on the data collected, the foam drainage test appears to identify stable combinations of AEA and WRA.
Resumo:
Portland cement concrete pavements have given excellent service history for Iowa. Many of these pavements placed during the 1920’s and 1930’s are still in service today. Many factors go in to achieve a long term durable concrete pavement. Probably the most important is the durability of the aggregate. Until the 1930’s, pit run gravel was the most predominant aggregate used. Many of these gravels provided long term performance and their durability is dependent upon the carbonate fraction of the gravel. Later, limestone (calcium carbonate) and dolomite (calcium, magnesium carbonate) sources were mined across Iowa. The durability of these carbonate aggregates is largely dependent upon the pore system which can cause freeze thaw problems known as D-cracking, which was a problem with some sources during the 1960’s. Also, some of these carbonate aggregates are also susceptible to deterioration from deicing salts. Geologists have identified the major components that affect the durability of these carbonate aggregates and sources are tested to ensure long term performance in Portland cement concrete. Air entrainment was originally put in concrete to improve scaling resistance. It is well known that air entrainment is required to provide freeze thaw protection in concrete pavements today. In Iowa, air entrainment was not introduced in concrete pavements until 1952. This research investigates properties that made older concrete pavements durable without air entrainment.
Resumo:
Plastic air content is typically tested by the pressure method, ASTM C138. Loss of air content through the paver has been shown to exceed 2 percent at times. Research has shown that early deterioration of pavements in Iowa may be directly or indirectly related to low or inadequate air content. Hardened air content is typically checked using the linear traverse method, ASTM C457. The linear traverse method is very time consuming and could not be used on a production scale. A quick and effective method of testing in place air content is needed. Research has shown a high degree of correlation with the high-pressure method of determining air content of hardened concrete versus plastic air content in laboratory conditions. This research indicated that air contents are more variable when comparing core results to plastic air content, although the overall average for the air content was comparable. Perhaps, the location of the plastic air content test, obtained from construction records, versus location of the cores was not as accurate as needed.
Resumo:
The Iowa DNR is asking for assistance from landowners and hunters in dealing with what it hopes is an isolated case of Chronic Wasting Disease (CWD) found in a wild deer harvested in Allamakee County. The
Resumo:
The aim of the present study is to investigate the effect of low-permeability concrete, made with reduced water‐to‐binder ratios (w/b) and/or supplementary cementitious materials (SCMs), on the need for air entrainment to achieve freezing‐thawing (F‐T) durability. In the present study, concrete mixes were made with different types of cement (Types I and IP), with or without fly ash replacement (15%), with different water‐to‐binder ratios (w/b =0.25, 0.35, 0.45 and 0.55), and with or without air entraining agent (AEA). All concrete mixtures were controlled to have a similar slump by using different dosages of superplasticizer. The rapid chloride permeability and F-T durability of the concrete samples were determined according to ASTM C1202 and ASTM C666A, respectively. The air void structure of the concrete was studied using the Air Void Analyzer, RapidAir, and porosity tests (ASTM C642). In addition, the general concrete properties, such as slump, air content, unit weight, and 28‐day compressive strength, were evaluated. The results indicate that all concrete mixes with proper air entrainment (ASTM C231 air content ≥ 6%) showed good F‐T resistance (durability factor ≥85%). All concrete mixes without AEA showed poor F‐T resistance (durability factor < 40%), except for one mix that had very low permeability and high strength. This was the concrete made with Type IP cement and with a w/b of 0.25, which had a permeability of 520 coulombs and a compressive strength of 12,760 psi (88 MPa). There were clear relationships between the F‐T durability and hardened concrete properties of non–air entrained concrete. However, such relationships did not exist in concrete with AEA. For concrete with AEA, good F‐T durability was associated with an air void spacing factor ≤ 0.28 mm (by AVA) or ≤ 0.22 mm (by RapidAir).
Resumo:
The U.S. Environmental Protection Agency (EPA), the Alcoa – Davenport Works Facility (Alcoa), and concerned citizens and community leaders of Riverdale, Iowa requested the Iowa Department of Public Health (IDPH) Hazardous Waste Site Health Assessment Program to evaluate the health impacts of exposures to volatile organic vapors detected within residences located immediately to the west of the Alcoa property. This health consultation addresses inhalation exposure to individuals that may have occupied the currently vacant residences in which the air sampling was completed.
Resumo:
The Iowa Behavioral Risk Factor Surveillance System (BRFSS) is an ongoing telephone survey. It is financially and technically supported by the CDC with further financial support from public and private sources. The BRFSS is designed to collect information on the health conditions, health-related behaviors, attitudes, and awareness of residents age 18 and over. It also monitors the prevalence of these indicators over time. The indicators surveyed are major contributors to illness, disability, and premature death. This report focuses on the data collected during calendar year 2013. Some of the health-related issues discussed are general health status, health care access, cancer screening, tobacco use, alcohol consumption, body weight, physical activity, oral health, diabetes, respiratory conditions, immunizations, and HIV/AIDS awareness.
Resumo:
The Iowa Behavioral Risk Factor Surveillance System (BRFSS) is an ongoing telephone survey. It is financially and technically supported by the CDC with further financial support from public and private sources. The BRFSS is designed to collect information on the health conditions, health-related behaviors, attitudes, and awareness of residents age 18 and over. It also monitors the prevalence of these indicators over time. The indicators surveyed are major contributors to illness, disability, and premature death. This report focuses on the data collected during calendar year 2013. Some of the health-related issues discussed are general health status, health care access, cancer screening, tobacco use, alcohol consumption, body weight, physical activity, oral health, diabetes, respiratory conditions, immunizations, and HIV/AIDS awareness.
Resumo:
A reference for all health care providers at the time of a suspected case, a particular disease or condition, or at the time of an outbreak of a communicable disease to institute public health prevention and control measures.
Resumo:
Promoting and protecting the health of Iowans is the mission of the Iowa Department of Public Health (IDPH). Surveillance of notifiable health conditions is essential in establishing what, how, and when events impact the public’s health. Once this information is gathered, public health and health care providers around the state are able to use this data to take steps to prevent illnesses from occurring. Multiple divisions and bureaus are dedicated to accomplishing the goals of surveillance. In 2014, there were more than 86,000 laboratory results of infectious diseases and conditions submitted to IDPH disease surveillance programs. IDPH also investigates non-infectious conditions related to lead, occupational, and environmental hazards like carbon monoxide. In 2014, approximately 71,000 children’s and more than 7,000 adults’ blood tests results were reported to IDPH. ********Amended Annual Report 2014************ Amended May 2, 2016
Resumo:
The Iowa Disease Surveillance System (IDSS) was developed by the Iowa Department of Public Health (IDPH) to streamline and enhance communication and collaboration between laboratory, hospital, and public health (local and state) personnel related to infectious disease surveillance and reporting (as required by Iowa Code 139A) throughout Iowa. IDSS is a tool that speeds communication regarding cases of reportable infectious disease to allow public health to respond sooner and reduce costs associated with disease reporting and surveillance.
Resumo:
Iowa's secondary roads contain nearly 15,000 bridges which are less than 40 feet (12 m) in length. Many of these bridges were built several decades ago and need to be replaced. Box culvert construction has proven to be an adequate bridge replacement technique. Recently a new bridge replacement alternative, called the Air-0-Form method, has emerged which has several potential advantages over box culvert construction. This new technique uses inflated balloons as the interior form in the construction of an arch culvert. The objective of research project HR-314 was to construct an air formed arch culvert to determine the applicability of the Air-O-Form technique as a county bridge replacement alternative.
Resumo:
A power point made by the IDPH on promoting and protecting the health of Iowans in the workplace.
Resumo:
The Iowa Influenza Surveillance Network (IISN) was established in 2004, though surveillance has been conducted at the Iowa Department of Public Health. Schools and long-term care facilities report data weekly into a Web-based reporting system. Schools report the number of students absent due to illness and the total enrolled. Long-term care facilities report cases of influenza and vaccination status of each case. Both passively report outbreaks of illness, including influenza, to IDPH.