5 resultados para wireless universal serial-bus dongle
Resumo:
Capsule endoscopy (CE) offers state-of-the-art imaging of the small bowel. In Crohn's disease its clinical role is still uncertain. This report analyses the usefulness of CE in patients with suspected Cronh's disease, in patients with established Crohn's disease (when assessing severity, occult gastrointestinal bleeding and/or as a guide to therapy), in patients with inflammatory bowel disease unclassified (IBDU), and in individuals with ulcerative colitis. The first item in this group is the most important although there is no strong evidence to establish the position of CE in the diagnostic workup. In patients with established Crohn's disease, recently developed activity scores are promising tools for an accurate assessment of severity. As a guide to therapy, CE should be focused on patients with unexplained symptoms when other investigations are inconclusive. In postoperative Crohn's Disease, international consensus recommended considering CE only if ileocolonoscopy is contraindicated or unsuccessful. In the case of IBDU, studies have shown a significant proportion of patients reclassified with Crohn's disease. In this setting, CE could have a role determining small bowel involvement. The role of CE in ulcerative colitis is limited. Some authors advocate CE before colectomy for refractory cases in order to exclude Crohn's disease. In summary, CE offers a new horizon in inflammatory bowel disease, and a better knowledge of mucosal abnormalities that could offer a paradigm shift: changing from symptom-based disease activity estimation to direct mucosal healing monitoring. Nevertheless, randomized controlled studies are still needed to provide stronger evidence in this setting.
Resumo:
The use of molecular tools for genotyping Mycobacterium tuberculosis isolates in epidemiological surveys in order to identify clustered and orphan strains requires faster response times than those offered by the reference method, IS6110 restriction fragment length polymorphism (RFLP) genotyping. A method based on PCR, the mycobacterial interspersed repetitive-unit-variable-number tandem-repeat (MIRU-VNTR) genotyping technique, is an option for fast fingerprinting of M. tuberculosis, although precise evaluations of correlation between MIRU-VNTR and RFLP findings in population-based studies in different contexts are required before the methods are switched. In this study, we evaluated MIRU-VNTR genotyping (with a set of 15 loci [MIRU-15]) in parallel to RFLP genotyping in a 39-month universal population-based study in a challenging setting with a high proportion of immigrants. For 81.9% (281/343) of the M. tuberculosis isolates, both RFLP and MIRU-VNTR types were obtained. The percentages of clustered cases were 39.9% (112/281) and 43.1% (121/281) for RFLP and MIRU-15 analyses, and the numbers of clusters identified were 42 and 45, respectively. For 85.4% of the cases, the RFLP and MIRU-15 results were concordant, identifying the same cases as clustered and orphan (kappa, 0.7). However, for the remaining 14.6% of the cases, discrepancies were observed: 16 of the cases clustered by RFLP analysis were identified as orphan by MIRU-15 analysis, and 25 cases identified as orphan by RFLP analysis were clustered by MIRU-15 analysis. When discrepant cases showing subtle genotypic differences were tolerated, the discrepancies fell from 14.6% to 8.6%. Epidemiological links were found for 83.8% of the cases clustered by both RFLP and MIRU-15 analyses, whereas for the cases clustered by RFLP or MIRU-VNTR analysis alone, links were identified for only 30.8% or 38.9% of the cases, respectively. The latter group of cases mainly comprised isolates that could also have been clustered, if subtle genotypic differences had been tolerated. MIRU-15 genotyping seems to be a good alternative to RFLP genotyping for real-time interventional schemes. The correlation between MIRU-15 and IS6110 RFLP findings was reasonable, although some uncertainties as to the assignation of clusters by MIRU-15 analysis were identified.
Resumo:
Boletín semanal para profesionales sanitarios de la Secretaría General de Salud Pública, Inclusión y Calidad de Vida de la Consejería de Salud y Bienestar Social
Resumo:
Boletín semanal para profesionales sanitarios de la Secretaría General de Salud Pública y Participación Social de la Consejería de Salud
Resumo:
Wireless capsule endoscopy (CE) is a technology developed for the endoscopic exploration of the small bowel. The first capsule model was approved by the Food and Drug Administration in 2001, and its first and essential indication was occult gastrointestinal (GI) bleeding. Over subsequent years, this technology has been refined to provide superior resolution, increased battery life, and capabilities to view different parts of the GI tract. Indeed, cases for which CE proved useful have increased significantly over the last few years, with new indications for the small bowel and technical improvements that have expanded its use to other parts of the GI tract, including the esophagus and colon. The main challenges in the development of CE are new devices with the ability to provide therapy, air inflation for a better vision of the small bowel, biopsy sampling systems attached to the capsule and the possibility to guide and move the capsule with an external motion control. In this article we review the current and new indications of CE, and the evolving technological changes shaping this technology, which has a promising potential in the coming future of gastroenterology.