4 resultados para ultra short pulse
Resumo:
BACKGROUND: Epidermal growth factor receptor (EGFR) and its downstream factors KRAS and BRAF are mutated in several types of cancer, affecting the clinical response to EGFR inhibitors. Mutations in the EGFR kinase domain predict sensitivity to the tyrosine kinase inhibitors gefitinib and erlotinib in lung adenocarcinoma, while activating point mutations in KRAS and BRAF confer resistance to the anti-EGFR monoclonal antibody cetuximab in colorectal cancer. The development of new generation methods for systematic mutation screening of these genes will allow more appropriate therapeutic choices. METHODS: We describe a high resolution melting (HRM) assay for mutation detection in EGFR exons 19-21, KRAS codon 12/13 and BRAF V600 using formalin-fixed paraffin-embedded samples. Somatic variation of KRAS exon 2 was also analysed by massively parallel pyrosequencing of amplicons with the GS Junior 454 platform. RESULTS: We tested 120 routine diagnostic specimens from patients with colorectal or lung cancer. Mutations in KRAS, BRAF and EGFR were observed in 41.9%, 13.0% and 11.1% of the overall samples, respectively, being mutually exclusive. For KRAS, six types of substitutions were detected (17 G12D, 9 G13D, 7 G12C, 2 G12A, 2 G12V, 2 G12S), while V600E accounted for all the BRAF activating mutations. Regarding EGFR, two cases showed exon 19 deletions (delE746-A750 and delE746-T751insA) and another two substitutions in exon 21 (one showed L858R with the resistance mutation T590M in exon 20, and the other had P848L mutation). Consistent with earlier reports, our results show that KRAS and BRAF mutation frequencies in colorectal cancer were 44.3% and 13.0%, respectively, while EGFR mutations were detected in 11.1% of the lung cancer specimens. Ultra-deep amplicon pyrosequencing successfully validated the HRM results and allowed detection and quantitation of KRAS somatic mutations. CONCLUSIONS: HRM is a rapid and sensitive method for moderate-throughput cost-effective screening of oncogene mutations in clinical samples. Rather than Sanger sequence validation, next-generation sequencing technology results in more accurate quantitative results in somatic variation and can be achieved at a higher throughput scale.
Resumo:
BACKGROUND Illiteracy, a universal problem, limits the utilization of the most widely used short cognitive tests. Our objective was to assess and compare the effectiveness and cost for cognitive impairment (CI) and dementia (DEM) screening of three short cognitive tests applicable to illiterates. METHODS Phase III diagnostic test evaluation study was performed during one year in four Primary Care centers, prospectively including individuals with suspicion of CI or DEM. All underwent the Eurotest, Memory Alteration Test (M@T), and Phototest, applied in a balanced manner. Clinical, functional, and cognitive studies were independently performed in a blinded fashion in a Cognitive Behavioral Neurology Unit, and the gold standard diagnosis was established by consensus of expert neurologists on the basis of these results. Effectiveness of tests was assessed as the proportion of correct diagnoses (diagnostic accuracy [DA]) and the kappa index of concordance (k) with respect to gold standard diagnoses. Costs were based on public prices at the time and hospital accounts. RESULTS The study included 139 individuals: 47 with DEM, 36 with CI, and 56 without CI. No significant differences in effectiveness were found among the tests. For DEM screening: Eurotest (k = 0.71 [0.59-0.83], DA = 0.87 [0.80-0.92]), M@T (k = 0.72 [0.60-0.84], DA = 0.87 [0.80-0.92]), Phototest (k = 0.70 [0.57-0.82], DA = 0.86 [0.79-0.91]). For CI screening: Eurotest (k = 0.67 [0.55-0.79]; DA = 0.83 [0.76-0.89]), M@T (k = 0.52 [0.37-0.67]; DA = 0.80 [0.72-0.86]), Phototest (k = 0.59 [0.46-0.72]; DA = 0.79 [0.71-0.86]). There were no differences in the cost of DEM screening, but the cost of CI screening was significantly higher with M@T (330.7 ± 177.1 €, mean ± sd) than with Eurotest (294.1 ± 195.0 €) or Phototest (296.0 ± 196. 5 €). Application time was shorter with Phototest (2.8 ± 0.8 min) than with Eurotest (7.1 ± 1.8 min) or M@T (6.8 ± 2.2 min). CONCLUSIONS Eurotest, M@T, and Phototest are equally effective. Eurotest and Phototest are both less expensive options but Phototest is the most efficient, requiring the shortest application time.
Resumo:
In recent years, some epidemiologic studies have attributed adverse effects of air pollutants on health not only to particles and sulfur dioxide but also to photochemical air pollutants (nitrogen dioxide and ozone). The effects are usually small, leading to some inconsistencies in the results of the studies. Furthermore, the different methodologic approaches of the studies used has made it difficult to derive generic conclusions. We provide here a quantitative summary of the short-term effects of photochemical air pollutants on mortality in seven Spanish cities involved in the EMECAM project, using generalized additive models from analyses of single and multiple pollutants. Nitrogen dioxide and ozone data were provided by seven EMECAM cities (Barcelona, Gijón, Huelva, Madrid, Oviedo, Seville, and Valencia). Mortality indicators included daily total mortality from all causes excluding external causes, daily cardiovascular mortality, and daily respiratory mortality. Individual estimates, obtained from city-specific generalized additive Poisson autoregressive models, were combined by means of fixed effects models and, if significant heterogeneity among local estimates was found, also by random effects models. Significant positive associations were found between daily mortality (all causes and cardiovascular) and NO(2), once the rest of air pollutants were taken into account. A 10 microg/m(3) increase in the 24-hr average 1-day NO(2)level was associated with an increase in the daily number of deaths of 0.43% [95% confidence interval (CI), -0.003-0.86%] for all causes excluding external. In the case of significant relationships, relative risks for cause-specific mortality were nearly twice as much as that for total mortality for all the photochemical pollutants. Ozone was independently related only to cardiovascular daily mortality. No independent statistically significant relationship between photochemical air pollutants and respiratory mortality was found. The results in this study suggest that, given the present levels of photochemical pollutants, people living in Spanish cities are exposed to health risks derived from air pollution.
Resumo:
Background. Hamstring injuries continue to affect active individuals and although inadequate muscle extensibility remains a commonly accepted factor, little is known about the most effective method to improve flexibility. Purpose. To determine if an isolated neurodynamic sciatic sliding technique would improve hamstring flexibility to a greater degree than stretching or a placebo intervention in asymptomatic subjects with short hamstring syndrome (SHS). Study Design. Randomized double-blinded controlled trial. Methods. One hundred and twenty subjects with SHS were randomized to 1 of 3 groups: neurodynamic sliding, hamstring stretching, and placebo control. Each subject's dominant leg was measured for straight leg raise (SLR) range of motion (ROM) before and after interventions. Data were analyzed with a 3 × 2 mixed model ANOVA followed by simple main effects analyses. Results. At the end of the study, more ROM was observed in the Neurodynamic and Stretching groups compared to the Control group and more ROM in the Neurodynamic group compared to Stretching group. Conclusion. Findings suggest that a neurodynamic sliding technique will increase hamstring flexibility to a greater degree than static hamstring stretching in healthy subjects with SHS. Clinical Relevance. The use of neurodynamic sliding techniques to improve hamstring flexibility in sports may lead to a decreased incidence in injuries; however, this needs to be formally tested.