3 resultados para two-crystal interference technique
Resumo:
BACKGROUND Hirschsprung disease (HSCR) is a congenital malformation of the hindgut produced by a disruption in neural crest cell migration during embryonic development. HSCR has a complex genetic etiology and mutations in several genes, mainly the RET proto-oncogene, have been related to the disease. There is a clear predominance of missense/nonsense mutations in these genes whereas copy number variations (CNVs) have been seldom described, probably due to the limitations of conventional techniques usually employed for mutational analysis. METHODS In this study we have aimed to analyze the presence of CNVs in some HSCR genes (RET, EDN3, GDNF and ZFHX1B) using the Multiple Ligation-dependent Probe Amplification (MLPA) approach. RESULTS Two alterations in the MLPA profiles of RET and EDN3 were detected, but a detailed inspection showed that the decrease in the corresponding dosages were due to point mutations affecting the hybridization probes regions. CONCLUSION Our results indicate that CNVs of the gene coding regions analyzed here are not a common molecular cause of Hirschsprung disease. However, further studies are required to determine the presence of CNVs affecting non-coding regulatory regions, as well as other candidate genes.
Resumo:
BACKGROUND Drugs for inhalation are the cornerstone of therapy in obstructive lung disease. We have observed that up to 75 % of patients do not perform a correct inhalation technique. The inability of patients to correctly use their inhaler device may be a direct consequence of insufficient or poor inhaler technique instruction. The objective of this study is to test the efficacy of two educational interventions to improve the inhalation techniques in patients with Chronic Obstructive Pulmonary Disease (COPD). METHODS This study uses both a multicenter patients´ preference trial and a comprehensive cohort design with 495 COPD-diagnosed patients selected by a non-probabilistic method of sampling from seven Primary Care Centers. The participants will be divided into two groups and five arms. The two groups are: 1) the patients´ preference group with two arms and 2) the randomized group with three arms. In the preference group, the two arms correspond to the two educational interventions (Intervention A and Intervention B) designed for this study. In the randomized group the three arms comprise: intervention A, intervention B and a control arm. Intervention A is written information (a leaflet describing the correct inhalation techniques). Intervention B is written information about inhalation techniques plus training by an instructor. Every patient in each group will be visited six times during the year of the study at health care center. DISCUSSION Our hypothesis is that the application of two educational interventions in patients with COPD who are treated with inhaled therapy will increase the number of patients who perform a correct inhalation technique by at least 25 %. We will evaluate the effectiveness of these interventions on patient inhalation technique improvement, considering that it will be adequate and feasible within the context of clinical practice.
Resumo:
BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.