2 resultados para successive extractions


Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the long-term impact of successive interventions on rates of methicillin-resistant Staphylococcus aureus (MRSA) colonization or infection and MRSA bacteremia in an endemic hospital-wide situation. DESIGN:Quasi-experimental, interrupted time-series analysis. The impact of the interventions was analyzed by use of segmented regression. Representative MRSA isolates were typed by use of pulsed-field gel electrophoresis. SETTING:A 950-bed teaching hospital in Seville, Spain. PATIENTS:All patients admitted to the hospital during the period from 1995 through 2008. METHODS:Three successive interventions were studied: (1) contact precautions, with no active surveillance for MRSA; (2) targeted active surveillance for MRSA in patients and healthcare workers in specific wards, prioritized according to clinical epidemiology data; and (3) targeted active surveillance for MRSA in patients admitted from other medical centers. RESULTS:Neither the preintervention rate of MRSA colonization or infection (0.56 cases per 1,000 patient-days [95% confidence interval {CI}, 0.49-0.62 cases per 1,000 patient-days]) nor the slope for the rate of MRSA colonization or infection changed significantly after the first intervention. The rate decreased significantly to 0.28 cases per 1,000 patient-days (95% CI, 0.17-0.40 cases per 1,000 patient-days) after the second intervention and to 0.07 cases per 1,000 patient-days (95% CI, 0.06-0.08 cases per 1,000 patient-days) after the third intervention, and the rate remained at a similar level for 8 years. The MRSA bacteremia rate decreased by 80%, whereas the rate of bacteremia due to methicillin-susceptible S. aureus did not change. Eighty-three percent of the MRSA isolates identified were clonally related. All MRSA isolates obtained from healthcare workers were clonally related to those recovered from patients who were in their care. CONCLUSION:Our data indicate that long-term control of endemic MRSA is feasible in tertiary care centers. The use of targeted active surveillance for MRSA in patients and healthcare workers in specific wards (identified by means of analysis of clinical epidemiology data) and the use of decolonization were key to the success of the program.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.