2 resultados para polymer interactions
Resumo:
Knowledge on the patterns of repetition amongst individuals who develop language deficits in association with right hemisphere lesions (crossed aphasia) is very limited. Available data indicate that repetition in some crossed aphasics experiencing phonological processing deficits is not heavily influenced by lexical-semantic variables (lexicality, imageability, and frequency) as is regularly reported in phonologically-impaired cases with left hemisphere damage. Moreover, in view of the fact that crossed aphasia is rare, information on the role of right cortical areas and white matter tracts underpinning language repetition deficits is scarce. In this study, repetition performance was assessed in two patients with crossed conduction aphasia and striatal/capsular vascular lesions encompassing the right arcuate fasciculus (AF) and inferior frontal-occipital fasciculus (IFOF), the temporal stem and the white matter underneath the supramarginal gyrus. Both patients showed lexicality effects repeating better words than non-words, but manipulation of other lexical-semantic variables exerted less influence on repetition performance. Imageability and frequency effects, production of meaning-based paraphrases during sentence repetition, or better performance on repeating novel sentences than overlearned clichés were hardly ever observed in these two patients. In one patient, diffusion tensor imaging disclosed damage to the right long direct segment of the AF and IFOF with relative sparing of the anterior indirect and posterior segments of the AF, together with fully developed left perisylvian white matter pathways. These findings suggest that striatal/capsular lesions extending into the right AF and IFOF in some individuals with right hemisphere language dominance are associated with atypical repetition patterns which might reflect reduced interactions between phonological and lexical-semantic processes.
Resumo:
BACKGROUND It is unknown if lack of polymer can provoke a different edge response in drug-eluting stents. The aim of this study was to compare edge vascular response between polymer-free paclitaxel-eluting stent (PF-PES) and polymer-based paclitaxel-eluting stents (PB-PES). METHODS AND RESULTS: A total of 165 eligible patients undergoing percutaneous coronary intervention were prospectively randomized 1:1 to receive either PF-PES or PB-PES. Those patients with paired intravascular ultrasound (IVUS) after procedure and at 9-month follow-up were included in this analysis.Seventy-six patients with 84 lesions, divided into PB-PES (38 patients, 41 lesions) and PF-PES groups (38 patients, 43 lesions) had paired post-procedure and 9-month follow-up IVUS and were therefore included in this substudy. There was a significant lumen decrease at the proximal edge of PF-PES (from 9.02±3.06 mm(2)to 8.47±3.05 mm(2); P=0.040), and a significant plaque increase at the distal edges of PF-PES (from 4.39±2.73 mm(2)to 4.78±2.63 mm(2); P=0.004). At the distal edge there was a significant plaque increase in the PF-PES compared to PB-PES (+8.0% vs. -0.6%, respectively; P=0.015) with subsequent lumen reduction (-5.2% vs. +6.0%, respectively; P=0.024). CONCLUSIONS PF-PES had significant plaque increase and lumen reduction at the distal edge as compared to PB-PES, probably due to difference in polymer-based drug-release kinetics between the 2 platforms.