3 resultados para latent trigger point


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Previous studies have demonstrated the efficacy of treatment for latent tuberculosis infection (TLTBI) in persons infected with the human immunodeficiency virus, but few studies have investigated the operational aspects of implementing TLTBI in the co-infected population.The study objectives were to describe eligibility for TLTBI as well as treatment prescription, initiation and completion in an HIV-infected Spanish cohort and to investigate factors associated with treatment completion. METHODS Subjects were prospectively identified between 2000 and 2003 at ten HIV hospital-based clinics in Spain. Data were obtained from clinical records. Associations were measured using the odds ratio (OR) and its 95% confidence interval (95% CI). RESULTS A total of 1242 subjects were recruited and 846 (68.1%) were evaluated for TLTBI. Of these, 181 (21.4%) were eligible for TLTBI either because they were tuberculin skin test (TST) positive (121) or because their TST was negative/unknown but they were known contacts of a TB case or had impaired immunity (60). Of the patients eligible for TLTBI, 122 (67.4%) initiated TLTBI: 99 (81.1%) were treated with isoniazid for 6, 9 or 12 months; and 23 (18.9%) with short-course regimens including rifampin plus isoniazid and/or pyrazinamide. In total, 70 patients (57.4%) completed treatment, 39 (32.0%) defaulted, 7 (5.7%) interrupted treatment due to adverse effects, 2 developed TB, 2 died, and 2 moved away. Treatment completion was associated with having acquired HIV infection through heterosexual sex as compared to intravenous drug use (OR:4.6; 95% CI:1.4-14.7) and with having taken rifampin and pyrazinamide for 2 months as compared to isoniazid for 9 months (OR:8.3; 95% CI:2.7-24.9). CONCLUSIONS A minority of HIV-infected patients eligible for TLTBI actually starts and completes a course of treatment. Obstacles to successful implementation of this intervention need to be addressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early studies in patients with systemic lupus erythematosus (SLE) reported increased incidence of tuberculosis. The tuberculin skin test (TST) is the technique of choice to detect latent tuberculosis infection (LTBI) but has several limitations. OBJECTIVES We compared TST and the newer T.SPOT.TB test to diagnose LTBI in SLE patients. METHODS In this observational cohort study conducted between August 2009 and February 2012, we recruited 92 patients from those attending the SLE clinic of our university hospital. Data recorded were epidemiological and sociodemographic characteristics. Laboratory analyses included TST and T.SPOT.TB tests. RESULTS Of the patients studied, 92% were women with an average age of 42.7 years. Overall, the degree of correlation between the two tests was low (Kappa index = 0.324) but was better in patients not receiving corticosteroids (CTC)/immunosuppressive (IS) therapy (Kappa = 0.436) and in those receiving hydroxychloroquine (Kappa = 0.473). While TST results were adversely affected by those receiving CTC and/or IS drugs (P = 0.021), the T.SPOT.TB results were not. CONCLUSION Although the TST test remains a useful tool for diagnosing LTBI in SLE patients, the T.SPOT.TB test is perhaps better employed when the patient is receiving CTC and/or IS drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.