8 resultados para gastrointestinal agent
Resumo:
Fecal incontinence (FI) is the involuntary loss of rectal contents through the anal canal. Reports of its prevalence vary from 1-21%. Studies, have demonstrated a positive effect on FI symptoms with injectable bulking agents. This study evaluated the safety and efficacy of NASHA/Dx gel in the treatment of FI. One hundred fifteen eligible patients suffering from FI received 4 injections of 1 mL NASHA/Dx gel. Primary efficacy was based on data from 86 patients that completed the study. This study demonstrated a ≥50% reduction from baseline in the number of FI episodes in 57.1% of patients at 6 months, and 64.0% at 12 months. Significant improvements (P < .001) were also noted in total number of both solid and loose FI episodes, FI free days, CCFIS, and FIQL scores in all 4 domains. The majority of the treatment related AEs (94.9%) were mild or moderate intensity, and (98.7%) of AEs resolved spontaneously, or following treatment, without sequelae. Results of this study indicate NASHA/Dx gel was efficacious in the treatment of FI. Treatment effect was significant both in reduction of number of FI episodes and disease specific quality of life at 6 months and lasted up to 12 months after treatment.
Resumo:
The prevalence of anemia across studies on patients with inflammatory bowel disease (IBD) is high (30%). Both iron deficiency (ID) and anemia of chronic disease contribute most to the development of anemia in IBD. The prevalence of ID is even higher (45%). Anemia and ID negatively impact the patient's quality of life. Therefore, together with an adequate control of disease activity, iron replacement therapy should start as soon as anemia or ID is detected to attain a normal hemoglobin (Hb) and iron status. Many patients will respond to oral iron, but compliance may be poor, whereas intravenous (i.v.) compounds are safe, provide a faster Hb increase and iron store repletion, and presents a lower rate of treatment discontinuation. Absolute indications for i.v. iron treatment should include severe anemia, intolerance or inappropriate response to oral iron, severe intestinal disease activity, or use of an erythropoietic stimulating agent. Four different products are principally used in clinical practice, which differ in their pharmacokinetic properties and safety profiles: iron gluconate and iron sucrose (lower single doses), and iron dextran and ferric carboxymaltose (higher single doses). After the initial resolution of anemia and the repletion of iron stores, the patient's hematological and iron parameters should be carefully and periodically monitored, and maintenance iron treatment should be provided as required. New i.v. preparations that allow for giving 1000-1500 mg in a single session, thus facilitating patient management, provide an excellent tool to prevent or treat anemia and ID in this patient population, which in turn avoids allogeneic blood transfusion and improves their quality of life.
Resumo:
BACKGROUND In the MACRO study, patients with metastatic colorectal cancer (mCRC) were randomised to first-line treatment with 6 cycles of capecitabine and oxaliplatin (XELOX) plus bevacizumab followed by either single-agent bevacizumab or XELOX plus bevacizumab until disease progression. An additional retrospective analysis was performed to define the prognostic value of tumour KRAS status on progression-free survival (PFS), overall survival (OS) and response rates. METHODOLOGY/PRINCIPAL FINDINGS KRAS data (tumour KRAS status and type of mutation) were collected by questionnaire from participating centres that performed KRAS analyses. These data were then cross-referenced with efficacy data for relevant patients in the MACRO study database. KRAS status was analysed in 394 of the 480 patients (82.1%) in the MACRO study. Wild-type (WT) KRAS tumours were found in 219 patients (56%) and mutant (MT) KRAS in 175 patients (44%). Median PFS was 10.9 months for patients with WT KRAS and 9.4 months for patients with MT KRAS tumours (p=0.0038; HR: 1.40; 95% CI:1.12-1.77). The difference in OS was also significant: 26.7 months versus 18.0 months for WT versus MT KRAS, respectively (p=0.0002; HR: 1.55; 95% CI: 1.23-1.96). Univariate and multivariate analyses showed that KRAS was an independent variable for both PFS and OS. Responses were observed in 126 patients (57.5%) with WT KRAS tumours and 76 patients (43.4%) with MT KRAS tumours (p=0.0054; OR: 1.77; 95% CI: 1.18-2.64). CONCLUSIONS/SIGNIFICANCE This analysis of the MACRO study suggests a prognostic role for tumour KRAS status in patients with mCRC treated with XELOX plus bevacizumab. For both PFS and OS, KRAS status was an independent factor in univariate and multivariate analyses.
Resumo:
Gut mesodermal tissues originate from the splanchnopleural mesenchyme. However, the embryonic gastrointestinal coelomic epithelium gives rise to mesenchymal cells, whose significance and fate are little known. Our aim was to investigate the contribution of coelomic epithelium-derived cells to the intestinal development. We have used the transgenic mouse model mWt1/IRES/GFP-Cre (Wt1(cre)) crossed with the Rosa26R-EYFP reporter mouse. In the gastrointestinal duct Wt1, the Wilms' tumor suppressor gene, is specific and dynamically expressed in the coelomic epithelium. In the embryos obtained from the crossbreeding, the Wt1-expressing cell lineage produces the yellow fluorescent protein (YFP) allowing for colocalization with differentiation markers through confocal microscopy and flow cytometry. Wt1(cre-YFP) cells were very abundant throughout the intestine during midgestation, declining in neonates. Wt1(cre-YFP) cells were also transiently observed within the mucosa, being apparently released into the intestinal lumen. YFP was detected in cells contributing to intestinal vascularization (endothelium, pericytes and smooth muscle), visceral musculature (circular, longitudinal and submucosal) as well as in Cajal and Cajal-like interstitial cells. Wt1(cre-YFP) mesenchymal cells expressed FGF9, a critical growth factor for intestinal development, as well as PDGFRα, mainly within developing villi. Thus, a cell population derived from the coelomic epithelium incorporates to the gut mesenchyme and contribute to a variety of intestinal tissues, probably playing also a signaling role. Our results support the origin of interstitial cells of Cajal and visceral circular muscle from a common progenitor expressing anoctamin-1 and SMCα-actin. Coelomic-derived cells contribute to the differentiation of at least a part of the interstitial cells of Cajal.
Resumo:
BACKGROUND AND STUDY AIMS Colon capsule endoscopy (CCE) was developed for the evaluation of colorectal pathology. In this study, our aim was to assess if a dual-camera analysis using CCE allows better evaluation of the whole gastrointestinal (GI) tract compared to a single-camera analysis. PATIENTS AND METHODS We included 21 patients (12 males, mean age 56.20 years) submitted for a CCE examination. After standard colon preparation, the colon capsule endoscope (PillCam Colon™) was swallowed after reinitiation from its "sleep" mode. Four physicians performed the analysis: two reviewed both video streams at the same time (dual-camera analysis); one analyzed images from one side of the device ("camera 1"); and the other reviewed the opposite side ("camera 2"). We compared numbers of findings from different parts of the entire GI tract and level of agreement among reviewers. RESULTS A complete evaluation of the GI tract was possible in all patients. Dual-camera analysis provided 16% and 5% more findings compared to camera 1 and camera 2 analysis, respectively. Overall agreement was 62.7% (kappa = 0.44, 95% CI: 0.373-0.510). Esophageal (kappa = 0.611) and colorectal (kappa = 0.595) findings had a good level of agreement, while small bowel (kappa = 0.405) showed moderate agreement. CONCLUSION The use of dual-camera analysis with CCE for the evaluation of the GI tract is feasible and detects more abnormalities when compared with single-camera analysis.
Resumo:
Wireless capsule endoscopy (CE) is a technology developed for the endoscopic exploration of the small bowel. The first capsule model was approved by the Food and Drug Administration in 2001, and its first and essential indication was occult gastrointestinal (GI) bleeding. Over subsequent years, this technology has been refined to provide superior resolution, increased battery life, and capabilities to view different parts of the GI tract. Indeed, cases for which CE proved useful have increased significantly over the last few years, with new indications for the small bowel and technical improvements that have expanded its use to other parts of the GI tract, including the esophagus and colon. The main challenges in the development of CE are new devices with the ability to provide therapy, air inflation for a better vision of the small bowel, biopsy sampling systems attached to the capsule and the possibility to guide and move the capsule with an external motion control. In this article we review the current and new indications of CE, and the evolving technological changes shaping this technology, which has a promising potential in the coming future of gastroenterology.
Resumo:
Obscure gastrointestinal bleeding is still a clinical challenge for gastroenterologists. The recent development of novel technologies for the diagnosis and treatment of different bleeding causes has allowed a better management of patients, but it also determines the need of a deeper comprehension of pathophysiology and the analysis of local expertise in order to develop a rational management algorithm. Obscure gastrointestinal bleeding can be divided in occult, when a positive occult blood fecal test is the main manifestation, and overt, when external sings of bleeding are visible. In this paper we are going to focus on overt gastrointestinal bleeding, describing the physiopathology of the most usual causes, analyzing the diagnostic procedures available, from the most classical to the novel ones, and establishing a standard algorithm which can be adapted depending on the local expertise or availability. Finally, we will review the main therapeutic options for this complex and not so uncommon clinical problem.
Resumo:
BACKGROUND AND STUDY AIMS Colon capsule endoscopy (CCE) was developed for the evaluation of colorectal pathology. In this study, our aim was to assess if a dual-camera analysis using CCE allows better evaluation of the whole gastrointestinal (GI) tract compared to a single-camera analysis. PATIENTS AND METHODS We included 21 patients (12 males, mean age 56.20 years) submitted for a CCE examination. After standard colon preparation, the colon capsule endoscope (PillCam Colon™) was swallowed after reinitiation from its "sleep" mode. Four physicians performed the analysis: two reviewed both video streams at the same time (dual-camera analysis); one analyzed images from one side of the device ("camera 1"); and the other reviewed the opposite side ("camera 2"). We compared numbers of findings from different parts of the entire GI tract and level of agreement among reviewers. RESULTS A complete evaluation of the GI tract was possible in all patients. Dual-camera analysis provided 16% and 5% more findings compared to camera 1 and camera 2 analysis, respectively. Overall agreement was 62.7% (kappa = 0.44, 95% CI: 0.373-0.510). Esophageal (kappa = 0.611) and colorectal (kappa = 0.595) findings had a good level of agreement, while small bowel (kappa = 0.405) showed moderate agreement. CONCLUSION The use of dual-camera analysis with CCE for the evaluation of the GI tract is feasible and detects more abnormalities when compared with single-camera analysis.