3 resultados para conclusions bias


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Mortality from invasive meningococcal disease (IMD) has remained stable over the last thirty years and it is unclear whether pre-hospital antibiotherapy actually produces a decrease in this mortality. Our aim was to examine whether pre-hospital oral antibiotherapy reduces mortality from IMD, adjusting for indication bias. Methods: A retrospective analysis was made of clinical reports of all patients (n = 848) diagnosed with IMD from 1995 to 2000 in Andalusia and the Canary Islands, Spain, and of the relationship between the use of pre-hospital oral antibiotherapy and mortality. Indication bias was controlled for by the propensity score technique, and a multivariate analysis was performed to determine the probability of each patient receiving antibiotics, according to the symptoms identified before admission. Data on in-hospital death, use of antibiotics and demographic variables were collected. A logistic regression analysis was then carried out, using death as the dependent variable, and prehospital antibiotic use, age, time from onset of symptoms to parenteral antibiotics and the propensity score as independent variables. Results: Data were recorded on 848 patients, 49 (5.72%) of whom died. Of the total number of patients, 226 had received oral antibiotics before admission, mainly betalactams during the previous 48 hours. After adjusting the association between the use of antibiotics and death for age, time between onset of symptoms and in-hospital antibiotic treatment, pre-hospital oral antibiotherapy remained a significant protective factor (Odds Ratio for death 0.37, 95% confidence interval 0.15–0.93). Conclusion: Pre-hospital oral antibiotherapy appears to reduce IMD mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND This paper discusses whether baseline demographic, socio-economic, health variables, length of follow-up and method of contacting the participants predict non-response to the invitation for a second assessment of lifestyle factors and body weight in the European multi-center EPIC-PANACEA study. METHODS Over 500.000 participants from several centers in ten European countries recruited between 1992 and 2000 were contacted 2-11 years later to update data on lifestyle and body weight. Length of follow-up as well as the method of approaching differed between the collaborating study centers. Non-responders were compared with responders using multivariate logistic regression analyses. RESULTS Overall response for the second assessment was high (81.6%). Compared to postal surveys, centers where the participants completed the questionnaire by phone attained a higher response. Response was also high in centers with a short follow-up period. Non-response was higher in participants who were male (odds ratio 1.09 (confidence interval 1.07; 1.11), aged under 40 years (1.96 (1.90; 2.02), living alone (1.40 (1.37; 1.43), less educated (1.35 (1.12; 1.19), of poorer health (1.33 (1.27; 1.39), reporting an unhealthy lifestyle and who had either a low (<18.5 kg/m2, 1.16 (1.09; 1.23)) or a high BMI (>25, 1.08 (1.06; 1.10); especially ≥30 kg/m2, 1.26 (1.23; 1.29)). CONCLUSIONS Cohort studies may enhance cohort maintenance by paying particular attention to the subgroups that are most unlikely to respond and by an active recruitment strategy using telephone interviews.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.