2 resultados para WIDE-RANGE CURRENT MEASUREMENT


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nutrition is the basis of human physiological processes. Inadequate nutrition can lead to dysfunction in the metabolic chain links. One of the most important micronutrients is zinc, as evidenced by its wide range of carriers in the body. Zinc intake has a large margin in the current world population, may be 7 mg/d in the UK, reaching 15 mg/d in the U.S., although of course, the RDA's are set according to age, sex , physiological status (pregnancy, lactation, etc..), or disease. It is known that zinc is essential for the structure and function as well as DNA and enzymes, coenzymes, hormones and so on. Life is short, zinc, since the most rapidly absorbed and is transferred to tanks where it is stored, so the amount available zinc in the blood cannot be the amount "real". In this work we have done a mini-review of the passage of zinc by the body trying since their intake to their tour of the blood in both healthy and sick people.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.