4 resultados para Supporting methodology
Resumo:
Introduction: Testing for HIV tropism is recommended before prescribing a chemokine receptor blocker. To date, in most European countries HIV tropism is determined using a phenotypic test. Recently, new data have emerged supporting the use of a genotypic HIV V3-loop sequence analysis as the basis for tropism determination. The European guidelines group on clinical management of HIV-1 tropism testing was established to make recommendations to clinicians and virologists. Methods: We searched online databases for articles from Jan 2006 until March 2010 with the terms: tropism or CCR5-antagonist or CCR5 antagonist or maraviroc or vicriviroc. Additional articles and/or conference abstracts were identified by hand searching. This strategy identified 712 potential articles and 1240 abstracts. All were reviewed and finally 57 papers and 42 abstracts were included and used by the panel to reach a consensus statement. Results: The panel recommends HIV-tropism testing for the following indications: i) drug-naïve patients in whom toxicity or limited therapeutic options are foreseen; ii) patients experiencing therapy failure whenever a treatment change is considered. Both the phenotypic Enhanced Trofile assay (ESTA) and genotypic population sequencing of the V3-loop are recommended for use in clinical practice. Although the panel does not recommend one methodology over another it is anticipated that genotypic testing will be used more frequently because of its greater accessibility, lower cost and shorter turnaround time. The panel also provides guidance on technical aspects and interpretation issues. If using genotypic methods, triplicate PCR amplification and sequencing testing is advised using the G2P interpretation tool (clonal model) with an FPR of 10%. If the viral load is below the level of reliable amplification, proviral DNA can be used, and the panel recommends performing triplicate testing and use of an FPR of 10%. If genotypic DNA testing is not performed in triplicate the FPR should be increased to 20%. Conclusions: The European guidelines on clinical management of HIV-1 tropism testing provide an overview of current literature, evidence-based recommendations for the clinical use of tropism testing and expert guidance on unresolved issues and current developments. Current data support both the use of genotypic population sequencing and ESTA for co-receptor tropism determination. For practical reasons genotypic population sequencing is the preferred method in Europe.
Resumo:
BACKGROUND Only multifaceted hospital wide interventions have been successful in achieving sustained improvements in hand hygiene (HH) compliance. METHODOLOGY/PRINCIPAL FINDINGS Pre-post intervention study of HH performance at baseline (October 2007-December 2009) and during intervention, which included two phases. Phase 1 (2010) included multimodal WHO approach. Phase 2 (2011) added Continuous Quality Improvement (CQI) tools and was based on: a) Increase of alcohol hand rub (AHR) solution placement (from 0.57 dispensers/bed to 1.56); b) Increase in frequency of audits (three days every three weeks: "3/3 strategy"); c) Implementation of a standardized register form of HH corrective actions; d) Statistical Process Control (SPC) as time series analysis methodology through appropriate control charts. During the intervention period we performed 819 scheduled direct observation audits which provided data from 11,714 HH opportunities. The most remarkable findings were: a) significant improvements in HH compliance with respect to baseline (25% mean increase); b) sustained high level (82%) of HH compliance during intervention; c) significant increase in AHRs consumption over time; c) significant decrease in the rate of healthcare-acquired MRSA; d) small but significant improvements in HH compliance when comparing phase 2 to phase 1 [79.5% (95% CI: 78.2-80.7) vs 84.6% (95% CI:83.8-85.4), p<0.05]; e) successful use of control charts to identify significant negative and positive deviations (special causes) related to the HH compliance process over time ("positive": 90.1% as highest HH compliance coinciding with the "World hygiene day"; and "negative":73.7% as lowest HH compliance coinciding with a statutory lay-off proceeding). CONCLUSIONS/SIGNIFICANCE CQI tools may be a key addition to WHO strategy to maintain a good HH performance over time. In addition, SPC has shown to be a powerful methodology to detect special causes in HH performance (positive and negative) and to help establishing adequate feedback to healthcare workers.
Resumo:
BACKGROUND Functional brain images such as Single-Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) have been widely used to guide the clinicians in the Alzheimer's Disease (AD) diagnosis. However, the subjectivity involved in their evaluation has favoured the development of Computer Aided Diagnosis (CAD) Systems. METHODS It is proposed a novel combination of feature extraction techniques to improve the diagnosis of AD. Firstly, Regions of Interest (ROIs) are selected by means of a t-test carried out on 3D Normalised Mean Square Error (NMSE) features restricted to be located within a predefined brain activation mask. In order to address the small sample-size problem, the dimension of the feature space was further reduced by: Large Margin Nearest Neighbours using a rectangular matrix (LMNN-RECT), Principal Component Analysis (PCA) or Partial Least Squares (PLS) (the two latter also analysed with a LMNN transformation). Regarding the classifiers, kernel Support Vector Machines (SVMs) and LMNN using Euclidean, Mahalanobis and Energy-based metrics were compared. RESULTS Several experiments were conducted in order to evaluate the proposed LMNN-based feature extraction algorithms and its benefits as: i) linear transformation of the PLS or PCA reduced data, ii) feature reduction technique, and iii) classifier (with Euclidean, Mahalanobis or Energy-based methodology). The system was evaluated by means of k-fold cross-validation yielding accuracy, sensitivity and specificity values of 92.78%, 91.07% and 95.12% (for SPECT) and 90.67%, 88% and 93.33% (for PET), respectively, when a NMSE-PLS-LMNN feature extraction method was used in combination with a SVM classifier, thus outperforming recently reported baseline methods. CONCLUSIONS All the proposed methods turned out to be a valid solution for the presented problem. One of the advances is the robustness of the LMNN algorithm that not only provides higher separation rate between the classes but it also makes (in combination with NMSE and PLS) this rate variation more stable. In addition, their generalization ability is another advance since several experiments were performed on two image modalities (SPECT and PET).
Resumo:
Substantial proportion of Crohn's disease (CD) patients shows no response or a limited response to treatment with infliximab (IFX) and to identify biomarkers of response would be of great clinical and economic benefit. The expression profile of five genes (S100A8-S100A9, G0S2, TNFAIP6, and IL11) reportedly predicted response to IFX and we aimed at investigating their etiologic role through genetic association analysis. Patients with active CD (350) who received at least three induction doses of IFX were included and classified according to IFX response. A tagging strategy was used to select genetic polymorphisms that cover the variability present in the chromosomal regions encoding the identified genes with altered expression. Following genotyping, differences between responders and nonresponders to IFX were observed in haplotypes of the studied regions: S100A8-S100A9 (rs11205276* G/rs3014866* C/rs724781* C/rs3006488* A; P = 0.05); G0S2 (rs4844486* A/rs1473683* T; P = 0.15); TNFAIP6 (rs11677200* C/rs2342910* A/rs3755480* G/rs10432475* A; P = 0.10); and IL11 (rs1126760* C/rs1042506* G; P = 0.07). These differences were amplified in patients with colonic and ileocolonic location for all but the TNFAIP6 haplotype, which evidenced significant difference in ileal CD patients. Our results support the role of the reported expression signature as predictive of anti-TNF outcome in CD patients and suggest an etiological role of those top-five genes in the IFX response pathway.