8 resultados para Reliability measure
Resumo:
BACKGROUND: Despite the progress over recent decades in developing community mental health services internationally, many people still receive treatment and care in institutional settings. Those most likely to reside longest in these facilities have the most complex mental health problems and are at most risk of potential abuses of care and exploitation. This study aimed to develop an international, standardised toolkit to assess the quality of care in longer term hospital and community based mental health units, including the degree to which human rights, social inclusion and autonomy are promoted. METHOD: The domains of care included in the toolkit were identified from a systematic literature review, international expert Delphi exercise, and review of care standards in ten European countries. The draft toolkit comprised 154 questions for unit managers. Inter-rater reliability was tested in 202 units across ten countries at different stages of deinstitutionalisation and development of community mental health services. Exploratory factor analysis was used to corroborate the allocation of items to domains. Feedback from those using the toolkit was collected about its usefulness and ease of completion. RESULTS: The toolkit had excellent inter-rater reliability and few items with narrow spread of response. Unit managers found the content highly relevant and were able to complete it in around 90 minutes. Minimal refinement was required and the final version comprised 145 questions assessing seven domains of care. CONCLUSIONS: Triangulation of qualitative and quantitative evidence directed the development of a robust and comprehensive international quality assessment toolkit for units in highly variable socioeconomic and political contexts
Resumo:
BACKGROUND. The NDI, COM and NPQ are evaluation instruments for disability due to NP. There was no Spanish version of NDI or COM for which psychometric characteristics were known. The objectives of this study were to translate and culturally adapt the Spanish version of the Neck Disability Index Questionnaire (NDI), and the Core Outcome Measure (COM), to validate its use in Spanish speaking patients with non-specific neck pain (NP), and to compare their psychometric characteristics with those of the Spanish version of the Northwick Pain Questionnaire (NPQ). METHODS. Translation/re-translation of the English versions of the NDI and the COM was done blindly and independently by a multidisciplinary team. The study was done in 9 primary care Centers and 12 specialty services from 9 regions in Spain, with 221 acute, subacute and chronic patients who visited their physician for NP: 54 in the pilot phase and 167 in the validation phase. Neck pain (VAS), referred pain (VAS), disability (NDI, COM and NPQ), catastrophizing (CSQ) and quality of life (SF-12) were measured on their first visit and 14 days later. Patients' self-assessment was used as the external criterion for pain and disability. In the pilot phase, patients' understanding of each item in the NDI and COM was assessed, and on day 1 test-retest reliability was estimated by giving a second NDI and COM in which the name of the questionnaires and the order of the items had been changed. RESULTS. Comprehensibility of NDI and COM were good. Minutes needed to fill out the questionnaires [median, (P25, P75)]: NDI. 4 (2.2, 10.0), COM: 2.1 (1.0, 4.9). Reliability: [ICC, (95%CI)]: NDI: 0.88 (0.80, 0.93). COM: 0.85 (0.75,0.91). Sensitivity to change: Effect size for patients having worsened, not changed and improved between days 1 and 15, according to the external criterion for disability: NDI: -0.24, 0.15, 0.66; NPQ: -0.14, 0.06, 0.67; COM: 0.05, 0.19, 0.92. Validity: Results of NDI, NPQ and COM were consistent with the external criterion for disability, whereas only those from NDI were consistent with the one for pain. Correlations with VAS, CSQ and SF-12 were similar for NDI and NPQ (absolute values between 0.36 and 0.50 on day 1, between 0.38 and 0.70 on day 15), and slightly lower for COM (between 0.36 and 0.48 on day 1, and between 0.33 and 0.61 on day 15). Correlation between NDI and NPQ: r = 0.84 on day 1, r = 0.91 on day 15. Correlation between COM and NPQ: r = 0.63 on day 1, r = 0.71 on day 15. CONCLUSION. Although most psychometric characteristics of NDI, NPQ and COM are similar, those from the latter one are worse and its use may lead to patients' evolution seeming more positive than it actually is. NDI seems to be the best instrument for measuring NP-related disability, since its results are the most consistent with patient's assessment of their own clinical status and evolution. It takes two more minutes to answer the NDI than to answer the COM, but it can be reliably filled out by the patient without assistance. TRIAL REGISTRATION Clinical Trials Register NCT00349544.
Resumo:
BACKGROUND: The Multiple Sclerosis International Quality Of Life (MusiQoL) questionnaire, a 31-item, multidimensional, self-administrated questionnaire that is available in 14 languages including Spanish, has been validated using a large international sample. We investigated the validity and reliability of the Spanish version of MusiQoL in Spain. METHODS: Consecutive patients with different types and severities of multiple sclerosis (MS) were recruited from 22 centres across Spain. All patients completed the MusiQoL questionnaire, the 36-Item Short Form (SF-36) health survey, and a symptoms checklist at baseline and 21 days later. External validity, internal consistency, reliability and reproducibility were tested. RESULTS: A total of 224 Spanish patients were evaluated. Dimensions of MusiQoL generally demonstrated a high internal consistency (Cronbach's alpha: 0.70-0.92 for all but two MusiQoL domain scores). External validity testing revealed that the MusiQoL index score correlated significantly with all SF-36 dimension scores (Pearson's correlation: 0.46-0.76), reproducibility was satisfactory (intraclass correlation coefficient: 0.60-0.91), acceptability was high, and the time taken to complete the 31-item questionnaire was reasonable (mean [standard deviation]: 9.8 [11.8] minutes). CONCLUSIONS: The Spanish version of the MusiQoL questionnaire appears to be a valid and reliable instrument for measuring quality of life in patients with MS in Spain and constitutes a useful instrument to measure health-related quality of life in the clinical setting.
Resumo:
Background: Hand hygiene in the health context is a complex behaviour. There have been rarely given the role of the knowledge and attitudes as predictors of hand hygiene behaviour. The main objective of this work is the description of the development of a questionnaire on hand hygiene and the analysis of their measurement properties. Method: An instrument which was designed and validated a questionnaire. It was held in January 2009. It finally has had 50 items that assess risk behaviour intention before and after contact with the patient, declarative knowledge and attitudes about hand hygiene. It has been applied to 431 students of health sciences at the University of Granada. Results: There were three factor analysis, ultimately obtaining a general convergence value that explains 46.01% of the total variance and high reliability (a=0,843). There is correlation between knowledge and behavior intentions before and after patient contact (p <0.01).In turn, the attitude correlates only with behavioral intention before (p <0.05). The hand hygiene behavior refers to a higher mean after the completion of various health activities before the same (4.26 and 3.96 respectively). Both declarative knowledge and attitudes significantly predict behavioral intention, in particular the conduct before the contact with the patient (R2 = 0.100, standardized Beta 0.256 for knowledge and 0.145 for attitudes). Conclusions: The questionnaire shows high internal consistency. We have obtained a valid tool for assessing risk behavior, knowledge and attitudes about students’ hand hygiene in health sciences. The tool detects deficiencies in basic skills in students.
Resumo:
BACKGROUND This study assesses the validity and reliability of the Spanish version of DN4 questionnaire as a tool for differential diagnosis of pain syndromes associated to a neuropathic (NP) or somatic component (non-neuropathic pain, NNP). METHODS A study was conducted consisting of two phases: cultural adaptation into the Spanish language by means of conceptual equivalence, including forward and backward translations in duplicate and cognitive debriefing, and testing of psychometric properties in patients with NP (peripheral, central and mixed) and NNP. The analysis of psychometric properties included reliability (internal consistency, inter-rater agreement and test-retest reliability) and validity (ROC curve analysis, agreement with the reference diagnosis and determination of sensitivity, specificity, and positive and negative predictive values in different subsamples according to type of NP). RESULTS A sample of 164 subjects (99 women, 60.4%; age: 60.4 +/- 16.0 years), 94 (57.3%) with NP (36 with peripheral, 32 with central, and 26 with mixed pain) and 70 with NNP was enrolled. The questionnaire was reliable [Cronbach's alpha coefficient: 0.71, inter-rater agreement coefficient: 0.80 (0.71-0.89), and test-retest intra-class correlation coefficient: 0.95 (0.92-0.97)] and valid for a cut-off value > or = 4 points, which was the best value to discriminate between NP and NNP subjects. DISCUSSION This study, representing the first validation of the DN4 questionnaire into another language different than the original, not only supported its high discriminatory value for identification of neuropathic pain, but also provided supplemental psychometric validation (i.e. test-retest reliability, influence of educational level and pain intensity) and showed its validity in mixed pain syndromes.
Resumo:
BACKGROUND Several questionnaires have been used to measure health related quality of life (HRQoL) in patients with psoriasis, few have been adapted for use in Spain; none of them was developed specifically for the Spanish population. The purpose of the study was to validate and assess the sensitivity to change of a new questionnaire to measure HRQOL in patients with psoriasis (PSO-LIFE). METHODS Observational, prospective, multicenter study performed in centers around Spain. Patients with active or inactive psoriasis completed the PSO-LIFE together with other Dermatology Quality of Life Index (DLQI) and Psoriasis Disability Index (PDI). A control group of patients with urticaria or atopic dermatitis was also included. Internal consistency and test-retest reliability of the PSO-LIFE were assessed by calculating Cronbach's alpha and Intraclass Correlation Coefficient (ICC). Validity was assessed by examining factorial structure, the capacity to discriminate between groups, and correlations with other measures. Sensitivity to change was measured using effect sizes. RESULTS The final sample included for analysis consisted of 304 patients and 56 controls. Mean (SD) age of psoriasis patients was 45.3 (14.5) years compared to 38.8 (14) years for controls (p < 0.01). Cronbach's alpha for the PSO-LIFE was 0.95 and test-retest reliability using the ICC was 0.98. Factor analysis showed the questionnaire to be unidimensional. Mean (SD) PSO-LIFE scores differed between patients with psoriasis and controls (64.9 [22.5] vs 69.4 [17.3]; p < 0.05), between those with active and inactive disease (57.4 [20.4] vs 76.4 [20.6]; p < 0.01), and between those with visible and non-visible lesions (63.0 [21.9] vs. 74.8 [23.9]; p < 0.01). The correlation between PSO-LIFE and PASI scores was moderate (r = -0.43) while correlations with DLQI and PDI dimensions ranged from moderate to high (between 0.4 and 0.8). Effect size on the PSO-LIFE in patients reporting 'much improved' health status at study completion was 1.01 (large effect size). CONCLUSIONS The present results provide substantial support for the reliability, validity, and responsiveness of the PSO-LIFE questionnaire in the population for which it was designed.
Resumo:
BACKGROUND Job satisfaction of nurses is a determinant factor in the quality and organizational adaptation of clinical management models in the current socio-economic context. The aim of this study was to construct and validate a questionnaire to measure job satisfaction of nurses in the Clinical Management Units in the Andalusian Public Health System. METHODS Clinimetric and cross-sectional study with a sample of 314 nurses of two university hospitals from Seville. Nurses were surveyed in 2011, from March to June. We used the Font Roja questionnaire adapted to our study variables. We performed analyses of correlations, reliability and construct validity, using exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) to test the a priori model. RESULTS The end questionnaire consists of 10 items, whose internal consistency was 0.75, with a percentage of variance explaining of 63.67%. CFA confirmed 4 dimensions (work environment, work relationships, motivation, and recognition): significant χ2 (p < .001); χ2/gl = 2.013; GFI= 0.958, RMR = 0.055 y RMSEA = 0.057; AGFI = 0.927, NFI = 0.878, TLI = 0.902, CFI =0.933 e IFI = 0.935; AIC = 132.486 y ECVI = 0.423. CONCLUSION This new questionnaire (G_Clinic) improves clinimetric values of the Font Roja questionnaire, because it reduces the number of items, improves the reliability of the dimensions, increases the value of variance explained, and allows knowing job satisfaction of nurses in clinical managementt.
Resumo:
BACKGROUND Some controversy remains about the potential applicability of cognitive potentials for evaluating the cerebral activity associated with cognitive capacity. A fundamental requirement is that these neurophysiological parameters show a high level of stability over time. Previous studies have shown that the reliability of diverse parameters of the P3 component (latency and amplitude) ranges between moderate and high. However, few studies have paid attention to the retest reliability of the P3 topography in groups or individuals. Considering that changes in P3 topography have been related to different pathologies and healthy aging, the main objective of this article was to evaluate in a longitudinal study (two sessions) the reliability of P3 topography in a group and at the individual level. RESULTS The correlation between sessions for P3 topography in the grand average of groups was high (r = 0.977, p<0.001). The within-subject correlation values ranged from 0.626 to 0.981 (mean: 0.888). In the between-subjects topography comparisons, the correlation was always lower for comparisons between different subjects than for within-subjects correlations in the first session but not in the second session. CONCLUSIONS The present study shows that P3 topography is highly reliable for group analysis (comprising the same subjects) in different sessions. The results also confirmed that retest reliability for individual P3 maps is suitable for follow-up studies for a particular subject. Moreover, P3 topography appears to be a specific marker considering that the between-subjects correlations were lower than the within-subject correlations. However, P3 topography appears more similar between subjects in the second session, demonstrating that is modulated by experience. Possible clinical applications of all these results are discussed.