6 resultados para Real effective exchange rate


Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND. Ritonavir-boosted saquinavir (SQVr) is nowadays regarded as an alternative antiretroviral drug probably due to several drawbacks, such as its high pill burden, twice daily dosing and the requirement of 200 mg ritonavir when given at the current standard 1000/100 mg bid dosing. Several once-daily SQVr dosing schemes have been studied with the 200 mg SQV old formulations, trying to overcome some of these disadvantages. SQV 500 mg strength tablets became available at the end of 2005, thus facilitating a once-daily regimen with fewer pills, although there is very limited experience with this formulation yet. METHODS. Prospective, multicentre study in which efficacy, safety and pharmacokinetics of a regimen of once-daily SQVr 1500/100 mg plus 2 NRTIs were evaluated under routine clinical care conditions in either antiretroviral-naïve patients or in those with no previous history of antiretroviral treatments and/or genotypic resistance tests suggesting SQV resistance. Plasma SQV trough levels were measured by HPLV-UV. RESULTS. Five hundred and fourteen caucasian patients were included (47.2% coinfected with hepatitis C and/or B virus; 7.8% with cirrhosis). Efficacy at 52 weeks (plasma RNA-HIV <50 copies/ml) was 67.7% (CI95: 63.6 - 71.7%) by intention-to-treat, and 92.2% (CI95: 89.8 - 94.6%) by on-treatment analysis. The reasons for failure were: dropout or loss to follow-up (18.4%), virological failure (7.8%), adverse events (3.1%), and other reasons (4.6%). The high rate of dropout may be explained by an enrollment and follow-up under routine clinical care condition, and a population with a significant number of drug users. The median SQV Cmin (n = 49) was 295 ng/ml (range, 53-2172). The only variable associated with virological failure in the multivariate analysis was adherence (OR: 3.36; CI95, 1.51-7.46, p = 0.003). CONCLUSIONS. Our results suggests that SQVr (1500/100 mg) once-daily plus 2 NRTIs is an effective regimen, without severe clinical adverse events or hepatotoxicity, scarce lipid changes, and no interactions with methadone. All these factors and its once-daily administration suggest this regimen as an appropriate option in patients with no SQV resistance-associated mutations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Functional brain images such as Single-Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) have been widely used to guide the clinicians in the Alzheimer's Disease (AD) diagnosis. However, the subjectivity involved in their evaluation has favoured the development of Computer Aided Diagnosis (CAD) Systems. METHODS It is proposed a novel combination of feature extraction techniques to improve the diagnosis of AD. Firstly, Regions of Interest (ROIs) are selected by means of a t-test carried out on 3D Normalised Mean Square Error (NMSE) features restricted to be located within a predefined brain activation mask. In order to address the small sample-size problem, the dimension of the feature space was further reduced by: Large Margin Nearest Neighbours using a rectangular matrix (LMNN-RECT), Principal Component Analysis (PCA) or Partial Least Squares (PLS) (the two latter also analysed with a LMNN transformation). Regarding the classifiers, kernel Support Vector Machines (SVMs) and LMNN using Euclidean, Mahalanobis and Energy-based metrics were compared. RESULTS Several experiments were conducted in order to evaluate the proposed LMNN-based feature extraction algorithms and its benefits as: i) linear transformation of the PLS or PCA reduced data, ii) feature reduction technique, and iii) classifier (with Euclidean, Mahalanobis or Energy-based methodology). The system was evaluated by means of k-fold cross-validation yielding accuracy, sensitivity and specificity values of 92.78%, 91.07% and 95.12% (for SPECT) and 90.67%, 88% and 93.33% (for PET), respectively, when a NMSE-PLS-LMNN feature extraction method was used in combination with a SVM classifier, thus outperforming recently reported baseline methods. CONCLUSIONS All the proposed methods turned out to be a valid solution for the presented problem. One of the advances is the robustness of the LMNN algorithm that not only provides higher separation rate between the classes but it also makes (in combination with NMSE and PLS) this rate variation more stable. In addition, their generalization ability is another advance since several experiments were performed on two image modalities (SPECT and PET).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Real-time PCR is a widely used tool for the diagnosis of many infectious diseases. However, little information exists about the influences of the different factors involved in PCR on the amplification efficiency. The aim of this study was to analyze the effect of boiling as the DNA preparation method on the efficiency of the amplification process of real-time PCR for the diagnosis of human brucellosis with serum samples. Serum samples from 10 brucellosis patients were analyzed by a SYBR green I LightCycler-based real-time PCR and by using boiling to obtain the DNA. DNA prepared by boiling lysis of the bacteria isolated from serum did not prevent the presence of inhibitors, such as immunoglobulin G (IgG), which were extracted with the template DNA. To identify and confirm the presence of IgG, serum was precipitated to separate and concentrate the IgG and was analyzed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and Western blotting. The use of serum volumes above 0.6 ml completely inhibited the amplification process. The inhibitory effect of IgG in serum samples was not concentration dependent, and it could be eliminated by diluting the samples 1/10 and 1/20 in water. Despite the lack of the complete elimination of the IgG from the template DNA, boiling does not require any special equipment and it provides a rapid, reproducible, and cost-effective method for the preparation of DNA from serum samples for the diagnosis of brucellosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Monotherapy against HIV has undoubted theoretical advantages and has good scientific fundaments. However, it is still controversial and here we will analyze the efficacy and safety of MT with darunavir with ritonavir (DRV/r) on patients who have received this treatment in our hospitals. MATERIALS AND METHODS Observational retrospective study that includes patients from 10 Andalusian hospitals that have received DRV/r in MT and that have been followed over a minimum of 12 months. We carried out a statistical descriptive analysis based on the profile of patients who had been prescribed MT and the efficacy and safety that were observed, paying special attention to treatment failure and virological evolution. RESULTS DRV/r was prescribed to 604 patients, of which 41.1% had a CD4 nadir <200/mmc. 33.1% had chronic hepatitis caused by HCV, had received an average of five lines of previous treatment and had a history of treatment failure to analogues in 33%, to non-analogues 22 and protease inhibitors (PI) in 19.5%. 76.6% proceeded from a previous treatment with PI. The simplification was the main criteria for the instauration of MT in the 81.5% and the adverse effects in the 18.5%. We managed to maintain MT in 84% of cases, with only 4.8% of virological failure (VF) with viral load (VL) >200 c/mL and 3.6% additional losses due to VF with VL between 50 and 200 copies/mL. Thirty three genotypes were performed after failure without findings of resistance mutations to DRV/r or other IPs. Only 23.7% of patients presented some blips during the period of exposition to MT. Eighty seven percent of all determinations of VL had <50 copies/mL, and only 4.99% had >200 copies/mL. Although up to 14.9% registered at some point an AE, only 2.6% abandoned MT because of AE and 1.2% because of voluntary decision. Although the average of total and LDL cholesterol increases 10 mg/dL after 2 years of follow-up, so did HDL cholesterol in 3mg/dL and the values of triglycerides (-14 mg/dL) and GPT (-6 UI/mL) decreased. The average count of CD4 lymphocytes increased from 642 to 714/mm(3) at 24 weeks. CONCLUSIONS In a very broad series of patients obtained from clinical practice, data from clinical trials was confirmed: MT with DRV as a de-escalation strategy is very safe, it's associated to a negligible rate of adverse effects and maintains a good suppression of HIV replication. VF (with >50 or >200 copies/mL) is always under 10% and in any case without consequences.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Measurement of biomarkers is a potential approach to early prediction of mortality in septic patients. The purpose of this study was to asses the prognostic value of proadrenomedullin (pADM) in adult patients with sepsis with a single measurement in the first 24 hours after the onset of severe sepsis or septic shock. Conclusions: The protein pADM is an important prognostic biomarker of survival when measured on admission of septic patients to the ICU.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Nucleic acid amplification tests are increasingly used for the rapid diagnosis of tuberculosis. We undertook a comparative study of the efficiency and diagnostic yield of a real-time PCR senX3-regX3 based assay versus the classical IS6110 target and the new commercial methods. METHODS This single-blind prospective comparative study included 145 consecutive samples: 76 from patients with culture-confirmed tuberculosis (86.8% pulmonary and 13.2% extrapulmonary tuberculosis: 48.7% smear-positive and 51.3% smear-negative) and 69 control samples (24 from patients diagnosed with non-tuberculous mycobacteria infections and 45 from patients with suspected tuberculosis which was eventually ruled out). All samples were tested by two CE-marked assays (Xpert®MTB/RIF and AnyplexTM plus MTB/NTM) and two in-house assays targeting senX3-regX3 and the IS6110 gene. RESULTS The detection limit ranged from 1.00E+01 fg for Anyplex, senX3-regX3 and IS6110 to 1.00E+04 fg for Xpert. All three Xpert, senX3-regX3 and IS6110 assays detected all 37 smear-positive cases. Conversely, Anyplex was positive in 34 (91.9%) smear-positive cases. In patients with smear-negative tuberculosis, differences were observed between the assays; Xpert detected 22 (56.41%) of the 39 smear-negative samples, Anyplex 24 (61.53%), senX3-regX3 28 (71.79%) and IS6110 35 (89.74%). Xpert and senX3-regX3 were negative in all control samples; however, the false positive rate was 8.7% and 13% for Anyplex and IS6110, respectively. The overall sensitivity was 77.6%, 85.7%, 77.3% and 94.7% and the specificity was 100%, 100%, 90.8% and 87.0% for the Xpert, senX3-regX3, Anyplex and IS6110 assays, respectively. CONCLUSION Real-time PCR assays targeting IS6110 lack the desired specificity. The Xpert MTB/RIF and in-house senX3-regX3 assays are both sensitive and specific for the detection of MTBC in both pulmonary and extrapulmonary samples. Therefore, the real time PCR senX3-regX3 based assay could be a useful and complementary tool in the diagnosis of tuberculosis.