3 resultados para Process Error


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Missed, delayed or incorrect diagnoses are considered to be diagnostic errors. The aim of this paper is to describe the methodology of a study to analyse cognitive aspects of the process by which primary care (PC) physicians diagnose dyspnoea. It examines the possible links between the use of heuristics, suboptimal cognitive acts and diagnostic errors, using Reason's taxonomy of human error (slips, lapses, mistakes and violations). The influence of situational factors (professional experience, perceived overwork and fatigue) is also analysed. METHODS Cohort study of new episodes of dyspnoea in patients receiving care from family physicians and residents at PC centres in Granada (Spain). With an initial expected diagnostic error rate of 20%, and a sampling error of 3%, 384 episodes of dyspnoea are calculated to be required. In addition to filling out the electronic medical record of the patients attended, each physician fills out 2 specially designed questionnaires about the diagnostic process performed in each case of dyspnoea. The first questionnaire includes questions on the physician's initial diagnostic impression, the 3 most likely diagnoses (in order of likelihood), and the diagnosis reached after the initial medical history and physical examination. It also includes items on the physicians' perceived overwork and fatigue during patient care. The second questionnaire records the confirmed diagnosis once it is reached. The complete diagnostic process is peer-reviewed to identify and classify the diagnostic errors. The possible use of heuristics of representativeness, availability, and anchoring and adjustment in each diagnostic process is also analysed. Each audit is reviewed with the physician responsible for the diagnostic process. Finally, logistic regression models are used to determine if there are differences in the diagnostic error variables based on the heuristics identified. DISCUSSION This work sets out a new approach to studying the diagnostic decision-making process in PC, taking advantage of new technologies which allow immediate recording of the decision-making process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The high prevalence of disease-related hospital malnutrition justifies the need for screening tools and early detection in patients at risk for malnutrition, followed by an assessment targeted towards diagnosis and treatment. At the same time there is clear undercoding of malnutrition diagnoses and the procedures to correct it Objectives: To describe the INFORNUT program/ process and its development as an information system. To quantify performance in its different phases. To cite other tools used as a coding source. To calculate the coding rates for malnutrition diagnoses and related procedures. To show the relationship to Mean Stay, Mortality Rate and Urgent Readmission; as well as to quantify its impact on the hospital Complexity Index and its effect on the justification of Hospitalization Costs. Material and methods: The INFORNUT® process is based on an automated screening program of systematic detection and early identification of malnourished patients on hospital admission, as well as their assessment, diagnoses, documentation and reporting. Of total readmissions with stays longer than three days incurred in 2008 and 2010, we recorded patients who underwent analytical screening with an alert for a medium or high risk of malnutrition, as well as the subgroup of patients in whom we were able to administer the complete INFORNUT® process, generating a report for each.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In epidemiologic studies, measurement error in dietary variables often attenuates association between dietary intake and disease occurrence. To adjust for the attenuation caused by error in dietary intake, regression calibration is commonly used. To apply regression calibration, unbiased reference measurements are required. Short-term reference measurements for foods that are not consumed daily contain excess zeroes that pose challenges in the calibration model. We adapted two-part regression calibration model, initially developed for multiple replicates of reference measurements per individual to a single-replicate setting. We showed how to handle excess zero reference measurements by two-step modeling approach, how to explore heteroscedasticity in the consumed amount with variance-mean graph, how to explore nonlinearity with the generalized additive modeling (GAM) and the empirical logit approaches, and how to select covariates in the calibration model. The performance of two-part calibration model was compared with the one-part counterpart. We used vegetable intake and mortality data from European Prospective Investigation on Cancer and Nutrition (EPIC) study. In the EPIC, reference measurements were taken with 24-hour recalls. For each of the three vegetable subgroups assessed separately, correcting for error with an appropriately specified two-part calibration model resulted in about three fold increase in the strength of association with all-cause mortality, as measured by the log hazard ratio. Further found is that the standard way of including covariates in the calibration model can lead to over fitting the two-part calibration model. Moreover, the extent of adjusting for error is influenced by the number and forms of covariates in the calibration model. For episodically consumed foods, we advise researchers to pay special attention to response distribution, nonlinearity, and covariate inclusion in specifying the calibration model.