2 resultados para Nondestructive Testing and Evaluation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Recently, different genetic variants located within the IL2/IL21 genetic region as well as within both IL2RA and IL2RB loci have been associated to multiple autoimmune disorders. We aimed to investigate for the first time the potential influence of the IL2/IL21, IL2RA and IL2RB most associated polymorphisms with autoimmunity on the endogenous non-anterior uveitis genetic predisposition. METHODS A total of 196 patients with endogenous non-anterior uveitis and 760 healthy controls, all of them from Caucasian population, were included in the current study. The IL2/IL21 (rs2069762, rs6822844 and rs907715), IL2RA (2104286, rs11594656 and rs12722495) and IL2RB (rs743777) genetic variants were genotyped using TaqMan® allelic discrimination assays. RESULTS A statistically significant difference was found for the rs6822844 (IL2/IL21 region) minor allele frequency in the group of uveitis patients compared with controls (P(-value)=0.02, OR=0.64 CI 95%=0.43-0.94) although the significance was lost after multiple testing correction. Furthermore, no evidence of association with uveitis was detected for the analyzed genetic variants of the IL2RA or IL2RB loci. CONCLUSION Our results indicate that analyzed IL2/IL21, IL2RA and IL2RB polymorphisms do not seem to play a significant role on the non-anterior uveitis genetic predisposition although further studies are needed in order to clear up the influence of these loci on the non-anterior uveitis susceptibility.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.