7 resultados para Microstrip Patch Antennas
Resumo:
BACKGROUND Skin patch test is the gold standard method in diagnosing contact allergy. Although used for more than 100 years, the patch test procedure is performed with variability around the world. A number of factors can influence the test results, namely the quality of reagents used, the timing of the application, the patch test series (allergens/haptens) that have been used for testing, the appropriate interpretation of the skin reactions or the evaluation of the patient's benefit. METHODS We performed an Internet -based survey with 38 questions covering the educational background of respondents, patch test methods and interpretation. The questionnaire was distributed among all representatives of national member societies of the World Allergy Organization (WAO), and the WAO Junior Members Group. RESULTS One hundred sixty-nine completed surveys were received from 47 countries. The majority of participants had more than 5 years of clinical practice (61 %) and routinely carried out patch tests (70 %). Both allergists and dermatologists were responsible for carrying out the patch tests. We could observe the use of many different guidelines regardless the geographical distribution. The use of home-made preparations was indicated by 47 % of participants and 73 % of the respondents performed 2 or 3 readings. Most of the responders indicated having patients with adverse reactions, including erythroderma (12 %); however, only 30 % of members completed a consent form before conducting the patch test. DISCUSSION The heterogeneity of patch test practices may be influenced by the level of awareness of clinical guidelines, different training backgrounds, accessibility to various types of devices, the patch test series (allergens/haptens) used for testing, type of clinical practice (public or private practice, clinical or research-based institution), infrastructure availability, financial/commercial implications and regulations among others. CONCLUSION There is a lack of a worldwide homogeneity of patch test procedures, and this raises concerns about the need for standardization and harmonization of this important diagnostic procedure.
Resumo:
Hemeoxygenase-2 (HO-2) is an antioxidant enzyme that can modulate recombinant maxi-K(+) channels and has been proposed to be the acute O(2) sensor in the carotid body (CB). We have tested the physiological contribution of this enzyme to O(2) sensing using HO-2 null mice. HO-2 deficiency leads to a CB phenotype characterized by organ growth and alteration in the expression of stress-dependent genes, including the maxi-K(+) channel alpha-subunit. However, sensitivity to hypoxia of CB is remarkably similar in HO-2 null animals and their control littermates. Moreover, the response to hypoxia in mouse and rat CB cells was maintained after blockade of maxi-K(+) channels with iberiotoxin. Hypoxia responsiveness of the adrenal medulla (AM) (another acutely responding O(2)-sensitive organ) was also unaltered by HO-2 deficiency. Our data suggest that redox disregulation resulting from HO-2 deficiency affects maxi-K(+) channel gene expression but it does not alter the intrinsic O(2) sensitivity of CB or AM cells. Therefore, HO-2 is not a universally used acute O(2) sensor.
Resumo:
About 2% of all paragangliomas are located in the chest, and a few have been described to be found in the heart. Primary cardiac paragangliomas are extremely uncommon tumors and surgical experience with this neoplasm is limited. Treatment strategies described in the literature have included simple excision, excision with reconstruction, autotransplantation after excision of the tumor and even orthotopic cardiac transplantation, depending on the extent of disease. A primary retrocardiac paraganglioma catecholamine-productive was identified in an asymptomatic 49-year old female associated to familial pheochromocytoma-paraganglioma syndrome caused by germline mutation of the gen which codifies for the subunit B of succinate dehydrogenase enzyme (SDHB). The neoplasm was surgically excised from the posterior surface of the left atrium via median sternotomy using cardiopulmonary bypass. Direct ligation of feeding vessels of the tumor along with left atrial reinforcement using a pericardial patch was performed. The post-operative course was uneventful, with normalization of catecholamine secretion and no recurrence at three-month follow-up. We review the current literature about this exceptional cardiac tumor, pathophysiological conditions and options for surgical management.
Resumo:
INTRODUCTION We functionally analyzed a frameshift mutation in the SCN5A gene encoding cardiac Na(+) channels (Nav1.5) found in a proband with repeated episodes of ventricular fibrillation who presented bradycardia and paroxysmal atrial fibrillation. Seven relatives also carry the mutation and showed a Brugada syndrome with an incomplete and variable expression. The mutation (p.D1816VfsX7) resulted in a severe truncation (201 residues) of the Nav1.5 C-terminus. METHODS AND RESULTS Wild-type (WT) and mutated Nav1.5 channels together with hNavβ1 were expressed in CHO cells and currents were recorded at room temperature using the whole-cell patch-clamp. Expression of p.D1816VfsX7 alone resulted in a marked reduction (≈90%) in peak Na(+) current density compared with WT channels. Peak current density generated by p.D1816VfsX7+WT was ≈50% of that generated by WT channels. p.D1816VfsX7 positively shifted activation and inactivation curves, leading to a significant reduction of the window current. The mutation accelerated current activation and reactivation kinetics and increased the fraction of channels developing slow inactivation with prolonged depolarizations. However, late INa was not modified by the mutation. p.D1816VfsX7 produced a marked reduction of channel trafficking toward the membrane that was not restored by decreasing incubation temperature during cell culture or by incubation with 300 μM mexiletine and 5 mM 4-phenylbutirate. CONCLUSION Despite a severe truncation of the C-terminus, the resulting mutated channels generate currents, albeit with reduced amplitude and altered biophysical properties, confirming the key role of the C-terminal domain in the expression and function of the cardiac Na(+) channel.
Resumo:
Objective: To asses the results of Autologous Chondrocyte Implantation (ACI) whith periosteal patch and To propagate the care circuits existing about in Andalusia. Material and Methods: From its of ficial licence in 2005, the tissue bank and the Virgen de la Victoria Hospital from Málaga, performed the ACI in the Andalusian public health system. 16 patients has been operated between 2006-2013, whith medium follow-up 47,6 months (6 months-6 years), from public hos- pitals throughout Andalucia, managed by hospital admission source and destination. Physiologically younger patients were selected (<50 años), with singles, > 2cm2 symptomatics chondral lesions, in stables and well aligned knees. ACI was used as res- cue procedure after microfracture ́s failure except osteochondritis dissecans. To assess the results the Concinnati score and the Short Form 36 (SF-36) score were used. A descriptive analysis was performed and non-parametric tests were used to establish correlations and compare results. Results: In 15 patients with more than one year of follow-up: 14 men(87.5%) and 2women (14.5%), medium age 28.2 years old (min 17 max 43), the lesion was located into de femoral condyle, mostly in the internal one (81,2%) with medium size 2,7cm2(2-4,2). We founded significant improvement (p<0,001), both daily activities ( 89,3% preop. limitatión - 9% postop), as in the sports (90,2% preop limitatión - 38% postop) and the exploration of the knee (67,7% hpatological findings preop- 13,3%postop). The SF-36 score improved in all categories, over all in mental health (p> 0,01). The patient satisfaction was high or very high in 12 of the 15 patients ( 80%), and low in 3 patients. Conclusions: ACI improve quality of life and knee function in femoral condyle chondral lesions. The case ́s selection and the collaboration with Tissue Bank, allows us to create care circuits for treatment of patients from other provinces in the Public Sanitary Health System in Andalucia. It is necessary to increase the experience with this type of therapy, consolidating multicenter workgroups that provide strength to the conclusions.
Resumo:
Objective: To outline the treatment by patches of microcurrent at home of patients with disabling knee osteoarthritis to perform their activities of daily life and work. Material and methods: We selected 80 patients in the surgical waiting list for total knee arthroplasty. 40 of whom received active patch and 40 inactive. All were given exercise protocol knee. The variables analyzed were: pain (VAS), joint balance, muscular balance and quality of life (SF-12). Patients were reviewed after two months of treatment. Variables were analyzed with SPSS 17.0 statistical program. Results: Statistically significant results were obtained (p <0.05) for decrease in mean pain according to VAS scale. No significant differences for other variables were found. Conclusions: Microcurrent therapy could be an alternative in the treatment of knee osteoarthritis pain, with no differences with the traditional treatment.
Resumo:
A 49-year-old woman, without known cardiovascular risk factors. Hoarseness of voice caused by a paralysis of left vocal cord. She was admitted to hospital because of acute coronary syndrome, associated to resuscitated cardiac arrest (asystolia documented) without later neurology sequels. Physical examination was anodyne. Echocardiographic study demonstrated a compatible image with a large left sinus of Valsalva aneurysm (SVA) (Panel A) and mild aortic regurgitation. Cardiac catheterization confirmed the presence of left SVA (Panel B) that produced extrinsic compression of the left main coronary artery (Panels C and D). Repair surgery was made by means of closing the aneurysmal orifice with a patch of dacron. Intra-operatory echocardiographic control study found severe aortic regurgitation, so valvular replacement with 19 mm mechanical prosthesis and extension of the valve annulus with patch of dacron was performed, associated with bypass with safena vein graft to left coronary artery. SVA is a very infrequent cardiac anomaly, generally with silent clinical course until it ruptures. Myocardial ischaemia caused by coronary artery compression is unusual. We described the case of a patient diagnosed of left SVA, whose initial clinical manifestation was the appearance of resuscitated sudden cardiac death in the context of an acute coronary syndrome.