2 resultados para Lower Semicontinuous Function


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The randomized placebo-controlled IFIGENIA-trial demonstrated that therapy with high-dose N-acetylcysteine (NAC) given for one year, added to prednisone and azathioprine, significantly ameliorates (i.e. slows down) disease progression in terms of vital capacity (VC) (+9%) and diffusing capacity (DLco) (+24%) in idiopathic pulmonary fibrosis (IPF). To better understand the clinical implications of these findings we performed additional, explorative analyses of the IFGENIA data set. METHODS We analysed effects of NAC on VC, DLco, a composite physiologic index (CPI), and mortality in the 155 study-patients. RESULTS In trial completers the functional indices did not change significantly with NAC, whereas most indices deteriorated with placebo; in non-completers the majority of indices worsened but decline was generally less pronounced in most indices with NAC than with placebo. Most categorical analyses of VC, DLco and CPI also showed favourable changes with NAC. The effects of NAC on VC, DLco and CPI were significantly better if the baseline CPI was 50 points or lower. CONCLUSION This descriptive analysis confirms and extends the favourable effects of NAC on lung function in IPF and emphasizes the usefulness of VC, DLco, and the CPI for the evaluation of a therapeutic effect. Most importantly, less progressed disease as indicated by a CPI of 50 points or lower at baseline was more responsive to therapy in this study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. METHODS AND RESULTS A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74-1.30; P=0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56-1.17; P=0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77-1.30; P=0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11-0.85; P=0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time (P=0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, -2.26; 95% confidence interval, -4.07 to -0.44; P=0.013; R(2)=0.121). CONCLUSIONS The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ≈2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time.