7 resultados para Lab tests
Resumo:
This paper introduces the evaluation report after fostering a Standard-based Interoperability Framework (SIF) between the Virgen del Rocío University Hospital (VRUH) Haemodialysis (HD) Unit and 5 outsourced HD centres in order to improve integrated care by automatically sharing patients' Electronic Health Record (EHR) and lab test reports. A pre-post study was conducted during fourteen months. The number of lab test reports of both emergency and routine nature regarding to 379 outpatients was computed before and after the integration of the SIF. Before fostering SIF, 19.38 lab tests per patient were shared between VRUH and HD centres, 5.52 of them were of emergency nature while 13.85 were routine. After integrating SIF, 17.98 lab tests per patient were shared, 3.82 of them were of emergency nature while 14.16 were routine. The inclusion of a SIF in the HD Integrated Care Process has led to an average reduction of 1.39 (p=0.775) lab test requests per patient, including a reduction of 1.70 (p=0.084) in those of emergency nature, whereas an increase of 0.31 (p=0.062) was observed in routine lab tests. Fostering this strategy has led to the reduction in emergency lab test requests, which implies a potential improvement of the integrated care.
Resumo:
BACKGROUND Illiteracy, a universal problem, limits the utilization of the most widely used short cognitive tests. Our objective was to assess and compare the effectiveness and cost for cognitive impairment (CI) and dementia (DEM) screening of three short cognitive tests applicable to illiterates. METHODS Phase III diagnostic test evaluation study was performed during one year in four Primary Care centers, prospectively including individuals with suspicion of CI or DEM. All underwent the Eurotest, Memory Alteration Test (M@T), and Phototest, applied in a balanced manner. Clinical, functional, and cognitive studies were independently performed in a blinded fashion in a Cognitive Behavioral Neurology Unit, and the gold standard diagnosis was established by consensus of expert neurologists on the basis of these results. Effectiveness of tests was assessed as the proportion of correct diagnoses (diagnostic accuracy [DA]) and the kappa index of concordance (k) with respect to gold standard diagnoses. Costs were based on public prices at the time and hospital accounts. RESULTS The study included 139 individuals: 47 with DEM, 36 with CI, and 56 without CI. No significant differences in effectiveness were found among the tests. For DEM screening: Eurotest (k = 0.71 [0.59-0.83], DA = 0.87 [0.80-0.92]), M@T (k = 0.72 [0.60-0.84], DA = 0.87 [0.80-0.92]), Phototest (k = 0.70 [0.57-0.82], DA = 0.86 [0.79-0.91]). For CI screening: Eurotest (k = 0.67 [0.55-0.79]; DA = 0.83 [0.76-0.89]), M@T (k = 0.52 [0.37-0.67]; DA = 0.80 [0.72-0.86]), Phototest (k = 0.59 [0.46-0.72]; DA = 0.79 [0.71-0.86]). There were no differences in the cost of DEM screening, but the cost of CI screening was significantly higher with M@T (330.7 ± 177.1 €, mean ± sd) than with Eurotest (294.1 ± 195.0 €) or Phototest (296.0 ± 196. 5 €). Application time was shorter with Phototest (2.8 ± 0.8 min) than with Eurotest (7.1 ± 1.8 min) or M@T (6.8 ± 2.2 min). CONCLUSIONS Eurotest, M@T, and Phototest are equally effective. Eurotest and Phototest are both less expensive options but Phototest is the most efficient, requiring the shortest application time.
Resumo:
BACKGROUND Preanalytical mistakes (PAMs) in samples usually led to rejection upon arrival to the clinical laboratory. However, PAMs might not always be detected and result in clinical problems. Thus, PAMs should be minimized. We detected PAMs in samples from Primary Health Care Centres (PHCC) served by our central laboratory. Thus, the goal of this study was to describe the number and types of PAMs, and to suggest some strategies for improvement. METHODS The presence of PAMs, as sample rejection criteria, in samples submitted from PHCC to our laboratory during October and November 2007 was retrospectively analysed. RESULTS Overall, 3885 PAMs (7.4%) were detected from 52,669 samples for blood analyses. This included missed samples (n=1763; 45.4% of all PAMs, 3.3% of all samples), haemolysed samples (n=1408; 36.2% and 2.7%, respectively), coagulated samples (n=391; 10% and 0.7%, respectively), incorrect sample volume (n=110; 2.8% and 0.2%, respectively), and others (n=213; 5.5% and 0.4%, respectively). For urine samples (n=18,852), 1567 of the samples were missing (8.3%). CONCLUSIONS We found the proportion of PAMs in blood and urine samples to be 3-fold higher than that reported in the literature. Therefore, strategies for improvement directed towards the staff involved, as well as an exhaustive audit of preanalytical process are needed. To attain this goal, we first implemented a continued education programme, financed by our Regional Health Service and focused in Primary Care Nurses.
Resumo:
Fragile X syndrome is the most common inherited form of intellectual disability. Here we report on a study based on a collaborative registry, involving 12 Spanish centres, of molecular diagnostic tests in 1105 fragile X families comprising 5062 individuals, of whom, 1655 carried a full mutation or were mosaic, three cases had deletions, 1840 had a premutation, and 102 had intermediate alleles. Two patients with the full mutation also had Klinefelter syndrome. We have used this registry to assess the risk of expansion from parents to children. From mothers with premutation, the overall rate of allele expansion to full mutation is 52.5%, and we found that this rate is higher for male than female offspring (63.6% versus 45.6%; P < 0.001). Furthermore, in mothers with intermediate alleles (45-54 repeats), there were 10 cases of expansion to a premutation allele, and for the smallest premutation alleles (55-59 repeats), there was a 6.4% risk of expansion to a full mutation, with 56 repeats being the smallest allele that expanded to a full mutation allele in a single meiosis. Hence, in our series the risk for alleles of <59 repeats is somewhat higher than in other published series. These findings are important for genetic counselling.
Resumo:
A workshop was convened to discuss best practices for the assessment of drug-induced liver injury (DILI) in clinical trials. In a breakout session, workshop attendees discussed necessary data elements and standards for the accurate measurement of DILI risk associated with new therapeutic agents in clinical trials. There was agreement that in order to achieve this goal the systematic acquisition of protocol-specified clinical measures and lab specimens from all study subjects is crucial. In addition, standard DILI terms that address the diverse clinical and pathologic signatures of DILI were considered essential. There was a strong consensus that clinical and lab analyses necessary for the evaluation of cases of acute liver injury should be consistent with the US Food and Drug Administration (FDA) guidance on pre-marketing risk assessment of DILI in clinical trials issued in 2009. A recommendation that liver injury case review and management be guided by clinicians with hepatologic expertise was made. Of note, there was agreement that emerging DILI signals should prompt the systematic collection of candidate pharmacogenomic, proteomic and/or metabonomic biomarkers from all study subjects. The use of emerging standardized clinical terminology, CRFs and graphic tools for data review to enable harmonization across clinical trials was strongly encouraged. Many of the recommendations made in the breakout session are in alignment with those made in the other parallel sessions on methodology to assess clinical liver safety data, causality assessment for suspected DILI, and liver safety assessment in special populations (hepatitis B, C, and oncology trials). Nonetheless, a few outstanding issues remain for future consideration.
Resumo:
Background: APACHE-II IS a score, based on several clinical and analytical measurements within 24 hours of admission in Intensive Care Unit (ICU). C-Reactive Protein (CRP), Lactate and recently Procalcitonin (PCT), also are biomarkers for the assessment of septic patients. The aim of this study was to find out if CRP, lactate and PCT during the first 24 hours from severe sepsis or septic shock onset, improved prediction of the APACHE II in terms of prognosis. Conclusions: CRP improves the prediction of patients with sepsis used in conjunction with the APACHE II score in severe sepsis and, lactate along with the CRP are the best precictors of survival in the cases of septic shock. The PCT did not show any predictive value.
Resumo:
BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.