7 resultados para Kinematic Data
Resumo:
Background. The use of hospital discharge administrative data (HDAD) has been recommended for automating, improving, even substituting, population-based cancer registries. The frequency of false positive and false negative cases recommends local validation. Methods. The aim of this study was to detect newly diagnosed, false positive and false negative cases of cancer from hospital discharge claims, using four Spanish population-based cancer registries as the gold standard. Prostate cancer was used as a case study. Results. A total of 2286 incident cases of prostate cancer registered in 2000 were used for validation. In the most sensitive algorithm (that using five diagnostic codes), estimates for Sensitivity ranged from 14.5% (CI95% 10.3-19.6) to 45.7% (CI95% 41.4-50.1). In the most predictive algorithm (that using five diagnostic and five surgical codes) Positive Predictive Value estimates ranged from 55.9% (CI95% 42.4-68.8) to 74.3% (CI95% 67.0-80.6). The most frequent reason for false positive cases was the number of prevalent cases inadequately considered as newly diagnosed cancers, ranging from 61.1% to 82.3% of false positive cases. The most frequent reason for false negative cases was related to the number of cases not attended in hospital settings. In this case, figures ranged from 34.4% to 69.7% of false negative cases, in the most predictive algorithm. Conclusions. HDAD might be a helpful tool for cancer registries to reach their goals. The findings suggest that, for automating cancer registries, algorithms combining diagnoses and procedures are the best option. However, for cancer surveillance purposes, in those cancers like prostate cancer in which care is not only hospital-based, combining inpatient and outpatient information will be required.
Resumo:
Hazardous chemical products have to comply with, amongst others, the provisions of a correct classification of danger, labelling and compilation of the safety data sheets. The aim is to protect people's health and the environment from exposure to hazardous chemicals- especially the health and safety of direct users, professionals or not, and the general public, via environmental exposure. This publication is intended to contribute to the knowledge of the objectives and basic aspects of these legal provisions, and thereby increase their degree of compliance in Andalusia and other european regions. This Guide is directed toward those people who, in the development of their professional activities, are in one way or another in contact with dangerous chemical products.
Resumo:
Hazardous chemical products have to comply with, amongst others, the provisions of a correct classification of danger, labelling and compilation of the safety data sheets. The aim is to protect people's health and the environment from exposure to hazardous chemicals- especially the health and safety of direct users, professionals or not, and the general public, via environmental exposure. This publication is intended to contribute to the knowledge of the objectives and basic aspects of these legal provisions, and thereby increase their degree of compliance in Andalusia and other european regions. This Guide is directed toward those people who, in the development of their professional activities, are in one way or another in contact with dangerous chemical products.
Resumo:
In their safety evaluations of bisphenol A (BPA), the U.S. Food and Drug Administration (FDA) and a counterpart in Europe, the European Food Safety Authority (EFSA), have given special prominence to two industry-funded studies that adhered to standards defined by Good Laboratory Practices (GLP). These same agencies have given much less weight in risk assessments to a large number of independently replicated non-GLP studies conducted with government funding by the leading experts in various fields of science from around the world. OBJECTIVES: We reviewed differences between industry-funded GLP studies of BPA conducted by commercial laboratories for regulatory purposes and non-GLP studies conducted in academic and government laboratories to identify hazards and molecular mechanisms mediating adverse effects. We examined the methods and results in the GLP studies that were pivotal in the draft decision of the U.S. FDA declaring BPA safe in relation to findings from studies that were competitive for U.S. National Institutes of Health (NIH) funding, peer-reviewed for publication in leading journals, subject to independent replication, but rejected by the U.S. FDA for regulatory purposes. DISCUSSION: Although the U.S. FDA and EFSA have deemed two industry-funded GLP studies of BPA to be superior to hundreds of studies funded by the U.S. NIH and NIH counterparts in other countries, the GLP studies on which the agencies based their decisions have serious conceptual and methodologic flaws. In addition, the U.S. FDA and EFSA have mistakenly assumed that GLP yields valid and reliable scientific findings (i.e., "good science"). Their rationale for favoring GLP studies over hundreds of publically funded studies ignores the central factor in determining the reliability and validity of scientific findings, namely, independent replication, and use of the most appropriate and sensitive state-of-the-art assays, neither of which is an expectation of industry-funded GLP research. CONCLUSIONS: Public health decisions should be based on studies using appropriate protocols with appropriate controls and the most sensitive assays, not GLP. Relevant NIH-funded research using state-of-the-art techniques should play a prominent role in safety evaluations of chemicals.
Resumo:
BACKGROUND Patients with chronic obstructive pulmonary disease (COPD) have a modified clinical presentation of venous thromboembolism (VTE) but also a worse prognosis than non-COPD patients with VTE. As it may induce therapeutic modifications, we evaluated the influence of the initial VTE presentation on the 3-month outcomes in COPD patients. METHODS COPD patients included in the on-going world-wide RIETE Registry were studied. The rate of pulmonary embolism (PE), major bleeding and death during the first 3 months in COPD patients were compared according to their initial clinical presentation (acute PE or deep vein thrombosis (DVT)). RESULTS Of the 4036 COPD patients included, 2452 (61%; 95% CI: 59.2-62.3) initially presented with PE. PE as the first VTE recurrence occurred in 116 patients, major bleeding in 101 patients and mortality in 443 patients (Fatal PE: first cause of death). Multivariate analysis confirmed that presenting with PE was associated with higher risk of VTE recurrence as PE (OR, 2.04; 95% CI: 1.11-3.72) and higher risk of fatal PE (OR, 7.77; 95% CI: 2.92-15.7). CONCLUSIONS COPD patients presenting with PE have an increased risk for PE recurrences and fatal PE compared with those presenting with DVT alone. More efficient therapy is needed in this subtype of patients.
Resumo:
Objectives. To study the utility of the Mini-Cog test for detection of patients with cognitive impairment (CI) in primary care (PC). Methods. We pooled data from two phase III studies conducted in Spain. Patients with complaints or suspicion of CI were consecutively recruited by PC physicians. The cognitive diagnosis was performed by an expert neurologist, after formal neuropsychological evaluation. The Mini-Cog score was calculated post hoc, and its diagnostic utility was evaluated and compared with the utility of the Mini-Mental State (MMS), the Clock Drawing Test (CDT), and the sum of the MMS and the CDT (MMS + CDT) using the area under the receiver operating characteristic curve (AUC). The best cut points were obtained on the basis of diagnostic accuracy (DA) and kappa index. Results. A total sample of 307 subjects (176 CI) was analyzed. The Mini-Cog displayed an AUC (±SE) of 0.78 ± 0.02, which was significantly inferior to the AUC of the CDT (0.84 ± 0.02), the MMS (0.84 ± 0.02), and the MMS + CDT (0.86 ± 0.02). The best cut point of the Mini-Cog was 1/2 (sensitivity 0.60, specificity 0.90, DA 0.73, and kappa index 0.48 ± 0.05). Conclusions. The utility of the Mini-Cog for detection of CI in PC was very modest, clearly inferior to the MMS or the CDT. These results do not permit recommendation of the Mini-Cog in PC.
Resumo:
Purpose: HIV-infected patients present an increased cardiovascular risk (CVR) of multifactorial origin, usually lower in women than in men. Information by gender about prevalence of modifiable risk factors is scarce. Methods: Coronator is a cross-sectional survey of a representative sample of HIV-infected patients on ART within 10 hospitals across Spain in 2011. Variables include sociodemographics, CVR factors and 10-year CV disease risk estimation (Regicor: Framingham score adapted to the Spanish population). Results: We included 860 patients (76.3% male) with no history of CVD. Median age 45.6 years; 84.1% were Spaniards; 29.9% women were IDUs. Median time since HIV diagnosis for men and women was 10 and 13 years (p=0.001), 28% had an AIDS diagnosis. Median CD4 cell count was 596 cells/mm3, 88% had undetectable viral load. Median time on ART was 91 and 108 months (p=0.017). There was a family history of early CVD in 113 men (17.9%) and 41 women (20.6%). Classical CVR factors are described in the table. Median (IQR) Regicor Score was 3% (2-5) for men and 2% (1-3) for women (p=0.000), and the proportion of subjects with mid-high risk (>5%) was 26.1% for men and 9.4% for women (p=0.000). Conclusions: In this population of HIV-infected patients, women have lower cardiovascular risk than men, partly due to higher levels of HDL cholesterol. Of note is the high frequency of smoking, abdominal obesity and sedentary lifestyle in our population. (Table Presented).