9 resultados para Joint replacement


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The optimum treatment for prosthetic joint infections has not been clearly defined. We report our experience of the management of acute haematogenous prosthetic joint infection (AHPJI) in patients during a 3-year prospective study in nine Spanish hospitals. Fifty patients, of whom 30 (60%) were female, with a median age of 76 years, were diagnosed with AHPJI. The median infection-free period following joint replacement was 4.9 years. Symptoms were acute in all cases. A distant previous infection and/or bacteraemia were identified in 48%. The aetiology was as follows: Staphylococcus aureus, 19; Streptococcus spp., 14; Gram-negative bacilli, 12; anaerobes, two; and mixed infections, three. Thirty-four (68%) patients were treated with a conservative surgical approach (CSA) with implant retention, and 16 had prosthesis removal. At 2-year follow-up, 24 (48%) were cured, seven (14%) had relapsed, seven (14%) had died, five (10%) had persistent infection, five had re-infection, and two had an unknown evolution. Overall, the treatment failure rates were 57.8% in staphylococcal infections and 14.3% in streptococcal infections. There were no failures in patients with Gram-negative bacillary. By multivariate analysis, CSA was the only factor independently associated with treatment failure (OR 11.6; 95% CI 1.29-104.8). We were unable to identify any factors predicting treatment failure in CSA patients, although a Gram-negative bacillary aetiology was a protective factor. These data suggest that although conservative surgery was the only factor independently associated with treatment failure, it could be the first therapeutic choice for the management of Gram-negative bacillary and streptococcal AHPJI, and for some cases with acute S. aureus infections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Associations of hormone-receptor positive breast cancer with excess adiposity are reasonably well characterized; however, uncertainty remains regarding the association of body mass index (BMI) with hormone-receptor negative malignancies, and possible interactions by hormone replacement therapy (HRT) use. METHODS Within the European EPIC cohort, Cox proportional hazards models were used to describe the relationship of BMI, waist and hip circumferences with risk of estrogen-receptor (ER) negative and progesterone-receptor (PR) negative (n = 1,021) and ER+PR+ (n = 3,586) breast tumors within five-year age bands. Among postmenopausal women, the joint effects of BMI and HRT use were analyzed. RESULTS For risk of ER-PR- tumors, there was no association of BMI across the age bands. However, when analyses were restricted to postmenopausal HRT never users, a positive risk association with BMI (third versus first tertile HR = 1.47 (1.01 to 2.15)) was observed. BMI was inversely associated with ER+PR+ tumors among women aged ≤49 years (per 5 kg/m2 increase, HR = 0.79 (95%CI 0.68 to 0.91)), and positively associated with risk among women ≥65 years (HR = 1.25 (1.16 to 1.34)). Adjusting for BMI, waist and hip circumferences showed no further associations with risks of breast cancer subtypes. Current use of HRT was significantly associated with an increased risk of receptor-negative (HRT current use compared to HRT never use HR: 1.30 (1.05 to 1.62)) and positive tumors (HR: 1.74 (1.56 to 1.95)), although this risk increase was weaker for ER-PR- disease (Phet = 0.035). The association of HRT was significantly stronger in the leaner women (BMI ≤22.5 kg/m2) than for more overweight women (BMI ≥25.9 kg/m2) for, both, ER-PR- (HR: 1.74 (1.15 to 2.63)) and ER+PR+ (HR: 2.33 (1.84 to 2.92)) breast cancer and was not restricted to any particular HRT regime. CONCLUSIONS An elevated BMI may be positively associated with risk of ER-PR- tumors among postmenopausal women who never used HRT. Furthermore, postmenopausal HRT users were at an increased risk of ER-PR- as well as ER+PR+ tumors, especially among leaner women. For hormone-receptor positive tumors, but not for hormone-receptor negative tumors, our study confirms an inverse association of risk with BMI among young women of premenopausal age. Our data provide evidence for a possible role of sex hormones in the etiology of hormone-receptor negative tumors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND. Total knee (TKR) and hip (THR) replacement (arthroplasty) are effective surgical procedures that relieve pain, improve patients' quality of life and increase functional capacity. Studies on variations in medical practice usually place the indications for performing these procedures to be highly variable, because surgeons appear to follow different criteria when recommending surgery in patients with different severity levels. We therefore proposed a study to evaluate inter-hospital variability in arthroplasty indication. METHODS. The pre-surgical condition of 1603 patients included was compared by their personal characteristics, clinical situation and self-perceived health status. Patients were asked to complete two health-related quality of life questionnaires: the generic SF-12 (Short Form) and the specific WOMAC (Western Ontario and Mcmaster Universities) scale. The type of patient undergoing primary arthroplasty was similar in the 15 different hospitals evaluated.The variability in baseline WOMAC score between hospitals in THR and TKR indication was described by range, mean and standard deviation (SD), mean and standard deviation weighted by the number of procedures at each hospital, high/low ratio or extremal quotient (EQ5-95), variation coefficient (CV5-95) and weighted variation coefficient (WCV5-95) for 5-95 percentile range. The variability in subjective and objective signs was evaluated using median, range and WCV5-95. The appropriateness of the procedures performed was calculated using a specific threshold proposed by Quintana et al for assessing pain and functional capacity. RESULTS. The variability expressed as WCV5-95 was very low, between 0.05 and 0.11 for all three dimensions on WOMAC scale for both types of procedure in all participating hospitals. The variability in the physical and mental SF-12 components was very low for both types of procedure (0.08 and 0.07 for hip and 0.03 and 0.07 for knee surgery patients). However, a moderate-high variability was detected in subjective-objective signs. Among all the surgeries performed, approximately a quarter of them could be considered to be inappropriate. CONCLUSIONS. A greater inter-hospital variability was observed for objective than for subjective signs for both procedures, suggesting that the differences in clinical criteria followed by surgeons when indicating arthroplasty are the main responsible factors for the variation in surgery rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The femoral periprosthetic fracture of the knee is one of the most feared complications because of its repercussions. Incidence are more and more likely due to the increase of total implanted arthroplasty of the knee, due to the increasing lifespan among the general population. The objective of this study is to analyze some of the perioperative aspects of the treatment of these fractures, comparing the use of osteosynthesis with plates and the retrograde nailing in those patients with femoral periprosthetic knee fractures with a stable implant. MATERIAL AND METODS: The study retrospectively examines 18 cases treated consecutively in our hospital (3 men and 15 women, average age of 72.7 years) between the years of 2000 and 2009. All fractures were located in the distal femur and on a stable implant. Eight were treated through retrograde nailing (Group I) and ten with plates (Group II). The cases are analyzed through the tests of the University of Mann-Withney and the exact Fischer test, with significant values of p≤0.05, the variables of median hospital stay, necessity of transfusion indicated with values of hemoglobin less than 8 mg/ml, preoperative radiological alignment and postoperative alignment of the total knee prosthesis (TKR), measured following the anatomical tibiofemoral axis, time of consolidation and incidence of localized complications in both groups. RESULTS: We did not find any statistically significant differences between the two groups in any of the variables analyzed. Localized complications are more frequent in Group I (62.5 percent of patients) than in Group II (10 percent of patients). The need for transfusion is greater in Group II (40 percent) than in Group I (12.5 percent). CONCLUSIONS: The type of implant used in treatment of femoral periprosthetic knee fracture does not significantly influence perioperative factors. The treatment for this type of fractures should be individually chosen in relation to the type of fracture, characteristics of the patient and stability and prosthesis model of the primary knee.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Assess the degree of satisfaction in a series of patients between 50 and 60 years of age who underwent surgery in our unicompartmental prosthesis unit (UPU) for monocompartmental gonarthrosis. Likewise, the definition based on current literature is assessed, as well as our experience in the indications, inconveniences and results of the internal knee unicompartmental arthroplasty discussed with supra-tuberosity tibial osteotomy, which was the common surgical option in these cases.MATERIAL AND METHOD: This study included 19 patients between 50 and 60 years of age (average age 56.7 years) (Interval of 51-60 years) intervened between 7/2007 and 11/2011 by the same surgeon (GDFB). Functional assessment used the Oxford Knee Score (OKS) questionnaire. A bibliographic search was performed in the MEDLINE, COCHRANE and EMBASE databases from 1988 to 2012. RESULTS: With an average follow-up of 29.4 months, 16 of 19 patients stated that they were satisfied with the results obtained and would repeat the intervention. One patient sufered a prosthetic infection and was reviewed for total knee replacement with good results. CONCLUSIONS: the medial, unicompartmental arthroplasty of the knee is a valid surgical option and reproducible in the medium term treatment of monocompartmental gonarthrosis in patients between 50 and 60 years of age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We carried out a descriptive, retrospective study with a sample side of 121 patients with Legión® prosthesis replacement in our Vírgen del Rocío hospital area, in the city of Seville, from May of 2008 until March of 2011. This study included epidemiological data as well as technical information about the process performed, including post-operative pain, mobility and functional results using a functional assessment scale and series of radiological studies. Average follow-up was 19 months, with a mean age of 71 years and 87% women. We obtained an average of 20.41º for articular balance obtained, correction of prior deformities by restoring the tibia-femoral axis to the anatomic e balance articular angle; we resolved bone loss prior to replacement and carried out an adequate balance of the inter-lineal joint. 66% of the patients continued with no post-operative pain, with the other 33% reporting slight to moderate pain. With regards to pain at the point of the stem, we have found no significant relationship with the incidence angle of the stem on the cortical or with the type of cement. We observed a 74% rate of intervention without complications, with complications being rupture of the patellar tendon in one patient, one case of peri-prosthesis fracture, two iatrogenic avulsion fractures of the anterior tibial tuberosity and seven infections (4 were diagnosed previously).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Popliteal pseudoaneurysm is a rare but important complication of knee arthroplasties. To our knowledge, this complication has not been reported previously in the literature after unicompartmental knee arthroplasty. Apart from intraoperatively caused arterial injuries, obese patients and other previous cardiovascular diseases may be potential factors of risks for pseudoaneurysm in knee surgeries. As it is an uncommon complication and it has inconspicuous symptoms, both diagnosis and treatment can be delayed. This means that a high level of suspicion is necessary to prevent serious complications derived from pseudoaneurysms. LEVEL OF EVIDENCE Level IV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: In patients with lateral osteoarthritis of the knee, use of external unicompartmental knee arthroplasty it is a well known surgical alternative, used by the minor trauma involved, short hospital stay and rapid recovery. The purpose of this study is to show the clinical outcomes to short-medium term of patients undergoing this procedure. Methods: we describe the technique used and the peculiarities of the prosthesis (A Mobile-bearing lateral unicompartmental knee replacement, Oxford Domed ®). This is an observational retrospective longitudinal study, of 15 arthroplasties performed in 13 women and 2 men, between 2010 and 2013, with a mean age of 60’7 years, with a diagnosis of lateral osteoarthritis of the knee, without involvement of the medial or patellofemoral compartment and cruciate ligaments functionally intact, with a mean follow up of 25 months. All patients complete the Oxford Knee Score and Visual Analog Scale (VAS) during the study. Results: The results are favorable, with an improvement of 6.60 points on the EVA, 3.73 for 1 in the postoperatory funcionality, the OKS very satisfactory with an average of 38 points over 50 and without any postoperative function surgical revision. Anserine tendinitis was observed in 20% of cases. Conclusions: The benefits of this surgery against their alternatives are assessed, and their potential drawbacks. External unicompartmental knee arthroplasty is an effective alternative in cases of knee osteoarthritis of the lateral compartment with no other associated injuries.