2 resultados para Joint Angle


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We carried out a descriptive, retrospective study with a sample side of 121 patients with Legión® prosthesis replacement in our Vírgen del Rocío hospital area, in the city of Seville, from May of 2008 until March of 2011. This study included epidemiological data as well as technical information about the process performed, including post-operative pain, mobility and functional results using a functional assessment scale and series of radiological studies. Average follow-up was 19 months, with a mean age of 71 years and 87% women. We obtained an average of 20.41º for articular balance obtained, correction of prior deformities by restoring the tibia-femoral axis to the anatomic e balance articular angle; we resolved bone loss prior to replacement and carried out an adequate balance of the inter-lineal joint. 66% of the patients continued with no post-operative pain, with the other 33% reporting slight to moderate pain. With regards to pain at the point of the stem, we have found no significant relationship with the incidence angle of the stem on the cortical or with the type of cement. We observed a 74% rate of intervention without complications, with complications being rupture of the patellar tendon in one patient, one case of peri-prosthesis fracture, two iatrogenic avulsion fractures of the anterior tibial tuberosity and seven infections (4 were diagnosed previously).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optimum treatment for prosthetic joint infections has not been clearly defined. We report our experience of the management of acute haematogenous prosthetic joint infection (AHPJI) in patients during a 3-year prospective study in nine Spanish hospitals. Fifty patients, of whom 30 (60%) were female, with a median age of 76 years, were diagnosed with AHPJI. The median infection-free period following joint replacement was 4.9 years. Symptoms were acute in all cases. A distant previous infection and/or bacteraemia were identified in 48%. The aetiology was as follows: Staphylococcus aureus, 19; Streptococcus spp., 14; Gram-negative bacilli, 12; anaerobes, two; and mixed infections, three. Thirty-four (68%) patients were treated with a conservative surgical approach (CSA) with implant retention, and 16 had prosthesis removal. At 2-year follow-up, 24 (48%) were cured, seven (14%) had relapsed, seven (14%) had died, five (10%) had persistent infection, five had re-infection, and two had an unknown evolution. Overall, the treatment failure rates were 57.8% in staphylococcal infections and 14.3% in streptococcal infections. There were no failures in patients with Gram-negative bacillary. By multivariate analysis, CSA was the only factor independently associated with treatment failure (OR 11.6; 95% CI 1.29-104.8). We were unable to identify any factors predicting treatment failure in CSA patients, although a Gram-negative bacillary aetiology was a protective factor. These data suggest that although conservative surgery was the only factor independently associated with treatment failure, it could be the first therapeutic choice for the management of Gram-negative bacillary and streptococcal AHPJI, and for some cases with acute S. aureus infections.