24 resultados para INTERVENTIONAL ENDOSCOPY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capsule endoscopy (CE) offers state-of-the-art imaging of the small bowel. In Crohn's disease its clinical role is still uncertain. This report analyses the usefulness of CE in patients with suspected Cronh's disease, in patients with established Crohn's disease (when assessing severity, occult gastrointestinal bleeding and/or as a guide to therapy), in patients with inflammatory bowel disease unclassified (IBDU), and in individuals with ulcerative colitis. The first item in this group is the most important although there is no strong evidence to establish the position of CE in the diagnostic workup. In patients with established Crohn's disease, recently developed activity scores are promising tools for an accurate assessment of severity. As a guide to therapy, CE should be focused on patients with unexplained symptoms when other investigations are inconclusive. In postoperative Crohn's Disease, international consensus recommended considering CE only if ileocolonoscopy is contraindicated or unsuccessful. In the case of IBDU, studies have shown a significant proportion of patients reclassified with Crohn's disease. In this setting, CE could have a role determining small bowel involvement. The role of CE in ulcerative colitis is limited. Some authors advocate CE before colectomy for refractory cases in order to exclude Crohn's disease. In summary, CE offers a new horizon in inflammatory bowel disease, and a better knowledge of mucosal abnormalities that could offer a paradigm shift: changing from symptom-based disease activity estimation to direct mucosal healing monitoring. Nevertheless, randomized controlled studies are still needed to provide stronger evidence in this setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS Colon capsule endoscopy (CCE) was developed for the evaluation of colorectal pathology. In this study, our aim was to assess if a dual-camera analysis using CCE allows better evaluation of the whole gastrointestinal (GI) tract compared to a single-camera analysis. PATIENTS AND METHODS We included 21 patients (12 males, mean age 56.20 years) submitted for a CCE examination. After standard colon preparation, the colon capsule endoscope (PillCam Colon™) was swallowed after reinitiation from its "sleep" mode. Four physicians performed the analysis: two reviewed both video streams at the same time (dual-camera analysis); one analyzed images from one side of the device ("camera 1"); and the other reviewed the opposite side ("camera 2"). We compared numbers of findings from different parts of the entire GI tract and level of agreement among reviewers. RESULTS A complete evaluation of the GI tract was possible in all patients. Dual-camera analysis provided 16% and 5% more findings compared to camera 1 and camera 2 analysis, respectively. Overall agreement was 62.7% (kappa = 0.44, 95% CI: 0.373-0.510). Esophageal (kappa = 0.611) and colorectal (kappa = 0.595) findings had a good level of agreement, while small bowel (kappa = 0.405) showed moderate agreement. CONCLUSION The use of dual-camera analysis with CCE for the evaluation of the GI tract is feasible and detects more abnormalities when compared with single-camera analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wireless capsule endoscopy (CE) is a technology developed for the endoscopic exploration of the small bowel. The first capsule model was approved by the Food and Drug Administration in 2001, and its first and essential indication was occult gastrointestinal (GI) bleeding. Over subsequent years, this technology has been refined to provide superior resolution, increased battery life, and capabilities to view different parts of the GI tract. Indeed, cases for which CE proved useful have increased significantly over the last few years, with new indications for the small bowel and technical improvements that have expanded its use to other parts of the GI tract, including the esophagus and colon. The main challenges in the development of CE are new devices with the ability to provide therapy, air inflation for a better vision of the small bowel, biopsy sampling systems attached to the capsule and the possibility to guide and move the capsule with an external motion control. In this article we review the current and new indications of CE, and the evolving technological changes shaping this technology, which has a promising potential in the coming future of gastroenterology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CD is a chronic inflammatory disorder associated to mucosal and transmural inflammation of the bowel wall. It is well known that CD can affect the entire gastrointestinal. Therefore, ileocolonoscopy and biopsies of the terminal ileum as well as of each colonic segment to look for microscopic evidence of CD are the first-line procedures to establish the diagnosis. However, it has been observed that up to 30% of the patients have only small bowel involvement. Evaluation of the small bowel has been made with radiological procedures, barium radiography, and abdominal computed tomography or by ileocolonoscopy or enteroscopy, but they have many recognized limitations. CE is undoubtedly a very useful diagnostic tool proposed to observe small-bowel lesions undetectable by conventional endoscopy or radiologic studies. We review different studies that have been published reporting the use of CE in suspected and evaluation of the extension or the recurrence in CD and also its use in pediatric population and its complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS Colon capsule endoscopy (CCE) was developed for the evaluation of colorectal pathology. In this study, our aim was to assess if a dual-camera analysis using CCE allows better evaluation of the whole gastrointestinal (GI) tract compared to a single-camera analysis. PATIENTS AND METHODS We included 21 patients (12 males, mean age 56.20 years) submitted for a CCE examination. After standard colon preparation, the colon capsule endoscope (PillCam Colon™) was swallowed after reinitiation from its "sleep" mode. Four physicians performed the analysis: two reviewed both video streams at the same time (dual-camera analysis); one analyzed images from one side of the device ("camera 1"); and the other reviewed the opposite side ("camera 2"). We compared numbers of findings from different parts of the entire GI tract and level of agreement among reviewers. RESULTS A complete evaluation of the GI tract was possible in all patients. Dual-camera analysis provided 16% and 5% more findings compared to camera 1 and camera 2 analysis, respectively. Overall agreement was 62.7% (kappa = 0.44, 95% CI: 0.373-0.510). Esophageal (kappa = 0.611) and colorectal (kappa = 0.595) findings had a good level of agreement, while small bowel (kappa = 0.405) showed moderate agreement. CONCLUSION The use of dual-camera analysis with CCE for the evaluation of the GI tract is feasible and detects more abnormalities when compared with single-camera analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CD is a chronic inflammatory disorder associated to mucosal and transmural inflammation of the bowel wall. It is well known that CD can affect the entire gastrointestinal. Therefore, ileocolonoscopy and biopsies of the terminal ileum as well as of each colonic segment to look for microscopic evidence of CD are the first-line procedures to establish the diagnosis. However, it has been observed that up to 30% of the patients have only small bowel involvement. Evaluation of the small bowel has been made with radiological procedures, barium radiography, and abdominal computed tomography or by ileocolonoscopy or enteroscopy, but they have many recognized limitations. CE is undoubtedly a very useful diagnostic tool proposed to observe small-bowel lesions undetectable by conventional endoscopy or radiologic studies. We review different studies that have been published reporting the use of CE in suspected and evaluation of the extension or the recurrence in CD and also its use in pediatric population and its complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Duodenal duplication cysts are rare congenital abnormalities which are more commonly diagnosed in infancy and childhood. However, in rare cases, these lesions can remain asymptomatic until adulthood. The combination of duplication cyst and pancreas divisum is extremely rare and both conditions have been linked with acute recurrent pancreatitis. We present the case of a 37 years-old patient who presented with repeated episodes of acute pancreatitis. By means of magnetic resonance imaging and endoscopic ultrasonography we discovered a duplication cyst whose cavity received drainage from the dorsal pancreas. After opening the cyst cavity to the duodenal lumen with a needle knife the patient presented no further episodes in the clinical follow-up. Comparable literature findings and therapeutic options for these abnormalities are discussed with regard to the presented case.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. Partial nephrectomy (PN) is playing an increasingly important role in localized renal cell carcinoma (RCC) as a true alternative to radical nephrectomy. With the greater experience and expertise of surgical teams, it has become an alternative to radical nephrectomy in young patients when the tumor diameter is 4 cm or less in almost all hospitals since cancer-specific survival outcomes are similar to those obtained with radical nephrectomy. Materials and Methods. The authors comment on their own experience and review the literature, reporting current indications and outcomes including complications. The surgical technique of open partial nephrectomy is outlined. Conclusions. Nowadays, open PN is the gold standard technique to treat small renal masses, and all nonablative techniques must pass the test of time to be compared to PN. It is not ethical for patients to undergo radical surgery just because the urologists involved do not have adequate experience with PN. Patients should be involved in the final treatment decision and, when appropriate, referred to specialized centers with experience in open or laparoscopic partial nephrectomies

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of molecular tools for genotyping Mycobacterium tuberculosis isolates in epidemiological surveys in order to identify clustered and orphan strains requires faster response times than those offered by the reference method, IS6110 restriction fragment length polymorphism (RFLP) genotyping. A method based on PCR, the mycobacterial interspersed repetitive-unit-variable-number tandem-repeat (MIRU-VNTR) genotyping technique, is an option for fast fingerprinting of M. tuberculosis, although precise evaluations of correlation between MIRU-VNTR and RFLP findings in population-based studies in different contexts are required before the methods are switched. In this study, we evaluated MIRU-VNTR genotyping (with a set of 15 loci [MIRU-15]) in parallel to RFLP genotyping in a 39-month universal population-based study in a challenging setting with a high proportion of immigrants. For 81.9% (281/343) of the M. tuberculosis isolates, both RFLP and MIRU-VNTR types were obtained. The percentages of clustered cases were 39.9% (112/281) and 43.1% (121/281) for RFLP and MIRU-15 analyses, and the numbers of clusters identified were 42 and 45, respectively. For 85.4% of the cases, the RFLP and MIRU-15 results were concordant, identifying the same cases as clustered and orphan (kappa, 0.7). However, for the remaining 14.6% of the cases, discrepancies were observed: 16 of the cases clustered by RFLP analysis were identified as orphan by MIRU-15 analysis, and 25 cases identified as orphan by RFLP analysis were clustered by MIRU-15 analysis. When discrepant cases showing subtle genotypic differences were tolerated, the discrepancies fell from 14.6% to 8.6%. Epidemiological links were found for 83.8% of the cases clustered by both RFLP and MIRU-15 analyses, whereas for the cases clustered by RFLP or MIRU-VNTR analysis alone, links were identified for only 30.8% or 38.9% of the cases, respectively. The latter group of cases mainly comprised isolates that could also have been clustered, if subtle genotypic differences had been tolerated. MIRU-15 genotyping seems to be a good alternative to RFLP genotyping for real-time interventional schemes. The correlation between MIRU-15 and IS6110 RFLP findings was reasonable, although some uncertainties as to the assignation of clusters by MIRU-15 analysis were identified.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Massive small bowel resection (MSBR) with a remnant jejunum shorter than 60 cm produces severe water, electrolytes, vitamins and protein-caloric depletion. While waiting for a viable intestinal transplantation, most of MSBR patients depend on total parenteral nutrition (TPN). CLINICAL CASE 32 years old male, with MSBR due to sectioning trauma of the superior mesenteric artery root. First surgical intervention: jejunostomy with small bowel, right colon, and spleen resection. Six months later: jejunocolic anastomosis with 12-cm long jejunum remnant and prophylactic cholecystectomy. NUTRITIONAL INTERVENTION: 1st phase. Hemodynamic stabilization and enteral stimulation (6 months): TPN + enteral nutrition with elemental formula + oral glucohydroelectrolitic solution (OGHS) + 15 g/d of oral glutamine + omeprazol. Clinical course indicators: biochemistry, I/L balance. 2a phase. Digestive adaptation with colonic integration (8 months): replacement of TPN by part-time peripheral PN. Progressive cooked diet complemented with pancreatic poly-enzyme preparation, omeprazol, OGHS, glutamine, elemental formula. Clinical course indicators: biochemistry, diuresis, weight and feces. 3a phase. Auto-sufficiency without parenteral dependence: fragmented free oral diet supplemented with pancreatic poly-enzyme preparation, mineralized beverages, enteral formula supplement, Ca and Mg oral supplements, oral multivitamin and mineral preparation, monthly IM vitamin B12. Current situation actual (52 months): slight ponderal gain, diuresis > liter/day, 2-3 normal feces, no clinical signs of any deficiency and normal blood levels of micronutrients. CONCLUSION It may be possible to withdraw from PN in MSBR considering, as in this case, favorable age and etiology and early implementation of an appropriate protocol of remnant adaptation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Complications resulting from gallstones left in the peritoneal cavity are most often reported after laparoscopic treatment of cholelitiasis. Gallstones are frequently dropped in the posterior subhepatic space, which can lead to the development of abscesses that usually require laparotomy for extraction of the stones. We present a novel technique for treating collections associated with dropped gallstones, using retroperitoneoscopy with two 10-mm ports after ultrasound localization of the abscess. We carried out this procedure in two patients and successfully extracted the gallstones without postoperative complications or recurrences. We consider this approach to be technically feasible, safe, and effective. It avoids the usual inefficacy of simple percutaneous drainage of these collections and the complications associated with the drainage of intra-abdominal abscesses by laparotomy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Endoscopic percutaneous gastrostomy is a safe technique although with potential complications before which the clinician has to be on alert in order to early detect them even after a long period of normal functioning. Most of them represent minor problems. Gastrocolocutaneous fistula is a rare but severe complication favored by some risk factors such as previous post-surgical adherences, deformities of the spine, or excessive gastric inflation at the time of performing the technique. We present the case of a patient with PEG with this complication that occurred after the first tube replacement. Our goal was in two senses: on the one hand, to analyze the preventive aspects and basic guidelines for a safe PEG placement to minimize the risks; on the other hand, to alert on the possible presence of this entity to prevent a progressive nutritional impairment. This complication ought to be included in the differential diagnosis of the diarrhea syndrome in the patient carrying a PEG. The diagnostic techniques of choice are radiologic tests such as CT scan and contrast media administration through the tube. Surgical therapy should be reserved to patients with acute peritonitis in order to perform a new gastrostomy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite advances in diagnosis, surgery, and antimicrobial therapy, mortality rates associated with complicated intra-abdominal infections remain exceedingly high. The World Society of Emergency Surgery (WSES) has designed the CIAOW study in order to describe the clinical, microbiological, and management-related profiles of both community- and healthcare-acquired complicated intra-abdominal infections in a worldwide context. The CIAOW study (Complicated Intra-Abdominal infection Observational Worldwide Study) is a multicenter observational study currently underway in 57 medical institutions worldwide. The study includes patients undergoing surgery or interventional drainage to address complicated intra-abdominal infections. This preliminary report includes all data from almost the first two months of the six-month study period. Patients who met inclusion criteria with either community-acquired or healthcare-associated complicated intra-abdominal infections (IAIs) were included in the study. 702 patients with a mean age of 49.2 years (range 18-98) were enrolled in the study. 272 patients (38.7%) were women and 430 (62.3%) were men. Among these patients, 615 (87.6%) were affected by community-acquired IAIs while the remaining 87 (12.4%) suffered from healthcare-associated infections. Generalized peritonitis was observed in 304 patients (43.3%), whereas localized peritonitis or abscesses was registered in 398 (57.7%) patients.The overall mortality rate was 10.1% (71/702). The final results of the CIAOW Study will be published following the conclusion of the study period in March 2013.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Iodine deficiency is an important clinical and public health problem. Its prevention begins with an adequate intake of iodine during pregnancy. International agencies recommend at least 200 microg iodine per d for pregnant women. We assessed whether iodine concentrations in the amniotic fluid of healthy pregnant women are independent of iodine intake. This cross-sectional, non-interventional study included 365 consecutive women who underwent amniocentesis to determine the fetal karyotype. The amniocentesis was performed with abdominal antisepsis using chlorhexidine. The iodine concentration was measured in urine and amniotic fluid. The study variables were the intake of iodized salt and multivitamin supplements or the prescription of a KI supplement. The mean level of urinary iodine was 139.0 (SD 94.5) microg/l and of amniotic fluid 15.81 (SD 7.09) microg/l. The women who consumed iodized salt and those who took a KI supplement had significantly higher levels of urinary iodine than those who did not (P = 0.01 and P = 0.004, respectively). The urinary iodine levels were not significantly different in the women who took a multivitamin supplement compared with those who did not take this supplement, independently of iodine concentration or multivitamin supplement. The concentrations of iodine in the amniotic fluid were similar, independent of the dietary iodine intake. Urine and amniotic fluid iodine concentrations were weakly correlated, although the amniotic fluid values were no higher in those women taking a KI supplement. KI prescription at recommended doses increases the iodine levels in the mother without influencing the iodine levels in the amniotic fluid.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sección "Buenas prácticas en gestión clínica"