2 resultados para High Pressure Grinding Rolls


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gluten content from barley, rye, wheat and in certain oat varieties, must be avoid in individuals with celiac disease. In most of the Western countries, the level of gluten content in food to be considered as gluten-free products is below 20 parts per million measured by ELISA based on specific anti-gluten peptide antibody. However, in beverages or food suffering complex hydrolytic processes as beers, the relative proportion of reactive peptides for celiac patients and the analytical techniques may differ, because of the diversity of the resulting peptide populations after fermentations. A beer below 20 parts per million of gluten but yet detectable levels of gluten peptides by anti-gliadin 33-mer antibodies (G12 and A1) was analyzed. We identified and characterized the relevant peptides for either antibody recognition or immunoactivity in celiac patients. The beer was fractionated by HPLC. The relative reactivity of the different HPLC fractions to the G12/A1 antibodies correlated to the reactivity of peripheral blood mononuclear cells isolated from 14 celiac individuals. Peptides from representative fractions classified according to the relative reactivity to G12/A1 antibodies were identified by mass spectrometry. The beer peptides containing sequences with similarity to those of previously described G12 and A1 epitopes were synthesized and confirmed significant reactivity for the antibodies. The most reactive peptides for G12/A1 also confirmed the highest immunogenicity by peripheral blood mononuclear cell activation and interferon γ production from celiac patients. We concluded that preparative HPLC combined with anti-gliadin 33-mer G12/A1 antibodies were very sensitive and specific methods to analyze the relevant immunogenic peptides in hydrolyzed gluten.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.