12 resultados para Evaluation methods
Resumo:
BACKGROUND The rate of avoidable caesarean sections (CS) could be reduced through multifaceted strategies focusing on the involvement of health professionals and compliance with clinical practice guidelines (CPGs). Quality improvements for CS (QICS) programmes (QICS) based on this approach, have been implemented in Canada and Spain. OBJECTIVES Their objectives are as follows: 1) Toto identify clusters in each setting with similar results in terms of cost-consequences, 2) Toto investigate whether demographic, clinical or context characteristics can distinguish these clusters, and 3) Toto explore the implementation of QICS in the 2 regions, in order to identify factors that have been facilitators in changing practices and reducing the use of obstetric intervention, as well as the challenges faced by hospitals in implementing the recommendations. METHODS Descriptive study with a quantitative and qualitative approach. 1) Cluster analysis at patient level with data from 16 hospitals in Quebec (Canada) (n = 105,348) and 15 hospitals in Andalusia (Spain) (n = 64,760). The outcome measures are CS and costs. For the cost, we will consider the intervention, delivery and complications in mother and baby, from the hospital perspective. Cluster analysis will be used to identify participants with similar patterns of CS and costs based, and t tests will be used to evaluate if the clusters differed in terms of characteristics: Hospital level (academic status of hospital, level of care, supply and demand factors), patient level (mother age, parity, gestational age, previous CS, previous pathology, presentation of the baby, baby birth weight). 2) Analysis of in-depth interviews with obstetricians and midwives in hospitals where the QICS were implemented, to explore the differences in delivery-related practices, and the importance of the different constructs for positive or negative adherence to CPGs. Dimensions: political/management level, hospital level, health professionals, mothers and their birth partner. DISCUSSION This work sets out a new approach for programme evaluation, using different techniques to make it possible to take into account the specific context where the programmes were implemented.
Resumo:
Background. During the last few years, PCR-based methods have been developed to simplify and reduce the time required for genotyping Mycobacterium tuberculosis (MTB) by standard approaches based on IS6110-Restriction Fragment Length Polymorphism (RFLP). Of these, MIRU-12-VNTR (Mycobacterial interspersed repetitive units- variable number of tandem repeats) (MIRU-12) has been considered a good alternative. Nevertheless, some limitations and discrepancies with RFLP, which are minimized if the technique is complemented with spoligotyping, have been found. Recently, a new version of MIRU-VNTR targeting 15 loci (MIRU-15) has been proposed to improve the MIRU-12 format. Results. We evaluated the new MIRU-15 tool in two different samples. First, we analyzed the same convenience sample that had been used to evaluate MIRU-12 in a previous study, and the new 15-loci version offered higher discriminatory power (Hunter-Gaston discriminatory index [HGDI]: 0.995 vs 0.978; 34.4% of clustered cases vs 57.5%) and better correlation (full or high correlation with RFLP for 82% of the clusters vs 47%). Second, we evaluated MIRU-15 on a population-based sample and, once again, good correlation with the RFLP clustering data was observed (for 83% of the RFLP clusters). To understand the meaning of the discrepancies still found between MIRU-15 and RFLP, we analyzed the epidemiological data for the clustered patients. In most cases, splitting of RFLP-clustered patients by MIRU-15 occurred for those without epidemiological links, and RFLP-clustered patients with epidemiological links were also clustered by MIRU-15, suggesting a good epidemiological background for clustering defined by MIRU-15. Conclusion. The data obtained by MIRU-15 suggest that the new design is very efficient at assigning clusters confirmed by epidemiological data. If we add this to the speed with which it provides results, MIRU-15 could be considered a suitable tool for real-time genotyping.
Resumo:
A new oligochromatographic assay, Speed-Oligo Novel Influenza A H1N1, was designed and optimized for the specific detection of the 2009 influenza A H1N1 virus. The assay is based on a PCR method coupled to detection of PCR products by means of a dipstick device. The target sequence is a 103-bp fragment within the hemagglutinin gene. The analytical sensitivity of the new assay was measured with serial dilutions of a plasmid that contained the target sequence, and we determined that down to one copy per reaction of the plasmid was reliably detected. Diagnostic performance was assessed with 103 RNAs from suspected cases (40 positive and 63 negative results) previously analyzed with a reference real-time PCR technique. All positive cases were confirmed, and no false-positive results were detected with the new assay. No cross-reactions were observed when other viral strains or clinical samples with other respiratory viruses were tested. According to these results, this new assay has 100% sensitivity and specificity. The turnaround time for the whole procedure was 140 min. The assay may be especially useful for the specific detection of 2009 H1N1 virus in laboratories not equipped with real-time PCR instruments
Resumo:
Objective. To evaluate the association between diabetes mellitus and health-related quality of life (HRQOL) controlled for several sociodemographic and anthropometric variables, in a representative sample of the Spanish population. Methods. A population-based, cross-sectional, and cluster sampling study, with the entire Spanish population as the target population. Five thousand and forty-seven participants (2162/2885 men/women) answered the HRQOL short form 12 questionnaire (SF-12). The physical (PCS-12) and the mental component summary (MCS-12) scores were assessed. Subjects were divided into four groups according to carbohydrate metabolism status: normal, prediabetes, unknown diabetes (UNKDM), and known diabetes (KDM). Logistic regression analyses were conducted. Results. Mean PCS-12/MCS-12 values were 50.9 ± 8.5/47.6 ± 10.2, respectively. Men had higher scores than women in both PCS-12 (51.8 ± 7.2 versus 50.3 ± 9.2; P < 0.001) and MCS-12 (50.2 ± 8.5 versus 45.5 ± 10.8; P < 0.001). Increasing age and obesity were associated with a poorer PCS-12 score. In women lower PCS-12 and MCS-12 scores were associated with a higher level of glucose metabolism abnormality (prediabetes and diabetes), (P < 0.0001 for trend), but only the PCS-12 score was associated with altered glucose levels in men (P < 0.001 for trend). The Odds Ratio adjusted for age, body mass index (BMI) and educational level, for a PCS-12 score below the median was 1.62 (CI 95%: 1.2–2.19; P < 0.002) for men with KDM and 1.75 for women with KDM (CI 95%: 1.26–2.43; P < 0.001), respectively. Conclusion. Current study indicates that increasing levels of altered carbohydrate metabolism are accompanied by a trend towards decreasing quality of life, mainly in women, in a representative sample of Spanish population.
Resumo:
Nonimmediate drug hypersensitivity reactions (DHRs) are difficult to manage in daily clinical practice, mainly owing to their heterogeneous clinical manifestations and the lack of selective biological markers. In vitro methods are necessaryto establish a diagnosis, especially given the low sensitivity of skin tests and the inherent risks of drug provocation testing. In vitro evaluation of nonimmediate DHRs must include approaches that can be applied during the different phases of the reaction. During the acute phase, monitoring markers in both skin and peripheral blood helps to discriminate between immediate and nonimmediate DHRs with cutaneous responses and to distinguish between reactions that, although they present similar clinical symptoms, are produced by different immunological mechanisms and therefore have a different treatment and prognosis. During the resolution phase, in vitro testing is used to detect the response of T cells to drug stimulation; however, this approach has certain limitations, such as the lack of validated studies assessing sensitivity. Moreover, in vitro tests indicate an immune response that is not always related to a DHR. In this review, members of the Immunology and Drug Allergy Committee of the Spanish Society of Allergy and Clinical Immunology (SEAIC) provide an overview of the most widely used in vitro tests for evaluating nonimmediate DHRs.
Resumo:
INTRODUCTION AND AIMS: Satisfaction of inpatients with served food within a hospital care system still constitutes one of the main attempts to modernize food services. The impact of type of menu, food category, hospital centre and timetable on the meals wastage produced in different Spanish healthcare settings, was evaluated. METHODS: Meal wastage was measured through a semiquantitative 5-point scale ("nothing on plate"; "¼ on plate"; "half on plate"; "¾ on plate" and "all on plate"). The study was carried out in two periods of three months each in 2010 and 2011. A trained person took charge of measuring plate waste classified into 726 servings belonging to 11 menus. In total 31,392 plates were served to 7,868 inpatients. A Kruskal-Wallis non-parametric test (p < 0.05) was applied to evaluate significant differences among the variables studied. RESULTS: The menus were satisfactorily consumed because more than 50% of the plates were classified as "nothing on plate". Regarding food categories, 26.78% of the plates corresponded to soups and purées, while pasta and rice, and prepared foods were only distributed in 4-5% of the servings. Desserts were mostly consumed, while cooked vegetables were less accepted by the inpatients evaluated. Other factors such as hospital centre influenced plate waste (p < 0.05) but timetable did not (p > 0.05). CONCLUSION: Visual inspections of plate waste might be useful to optimize type and quality of menus served. The type of menu served and the food category could have a great influence on food acceptability by the inpatientsstudied.
Resumo:
BACKGROUND The Bladder Cancer Index (BCI) is so far the only instrument applicable across all bladder cancer patients, independent of tumor infiltration or treatment applied. We developed a Spanish version of the BCI, and assessed its acceptability and metric properties. METHODS For the adaptation into Spanish we used the forward and back-translation method, expert panels, and cognitive debriefing patient interviews. For the assessment of metric properties we used data from 197 bladder cancer patients from a multi-center prospective study. The Spanish BCI and the SF-36 Health Survey were self-administered before and 12 months after treatment. Reliability was estimated by Cronbach's alpha. Construct validity was assessed through the multi-trait multi-method matrix. The magnitude of change was quantified by effect sizes to assess responsiveness. RESULTS Reliability coefficients ranged 0.75-0.97. The validity analysis confirmed moderate associations between the BCI function and bother subscales for urinary (r = 0.61) and bowel (r = 0.53) domains; conceptual independence among all BCI domains (r ≤ 0.3); and low correlation coefficients with the SF-36 scores, ranging 0.14-0.48. Among patients reporting global improvement at follow-up, pre-post treatment changes were statistically significant for the urinary domain and urinary bother subscale, with effect sizes of 0.38 and 0.53. CONCLUSIONS The Spanish BCI is well accepted, reliable, valid, responsive, and similar in performance compared to the original instrument. These findings support its use, both in Spanish and international studies, as a valuable and comprehensive tool for assessing quality of life across a wide range of bladder cancer patients.
Resumo:
BACKGROUND Recently, different genetic variants located within the IL2/IL21 genetic region as well as within both IL2RA and IL2RB loci have been associated to multiple autoimmune disorders. We aimed to investigate for the first time the potential influence of the IL2/IL21, IL2RA and IL2RB most associated polymorphisms with autoimmunity on the endogenous non-anterior uveitis genetic predisposition. METHODS A total of 196 patients with endogenous non-anterior uveitis and 760 healthy controls, all of them from Caucasian population, were included in the current study. The IL2/IL21 (rs2069762, rs6822844 and rs907715), IL2RA (2104286, rs11594656 and rs12722495) and IL2RB (rs743777) genetic variants were genotyped using TaqMan® allelic discrimination assays. RESULTS A statistically significant difference was found for the rs6822844 (IL2/IL21 region) minor allele frequency in the group of uveitis patients compared with controls (P(-value)=0.02, OR=0.64 CI 95%=0.43-0.94) although the significance was lost after multiple testing correction. Furthermore, no evidence of association with uveitis was detected for the analyzed genetic variants of the IL2RA or IL2RB loci. CONCLUSION Our results indicate that analyzed IL2/IL21, IL2RA and IL2RB polymorphisms do not seem to play a significant role on the non-anterior uveitis genetic predisposition although further studies are needed in order to clear up the influence of these loci on the non-anterior uveitis susceptibility.
Resumo:
The optimum treatment for prosthetic joint infections has not been clearly defined. We report our experience of the management of acute haematogenous prosthetic joint infection (AHPJI) in patients during a 3-year prospective study in nine Spanish hospitals. Fifty patients, of whom 30 (60%) were female, with a median age of 76 years, were diagnosed with AHPJI. The median infection-free period following joint replacement was 4.9 years. Symptoms were acute in all cases. A distant previous infection and/or bacteraemia were identified in 48%. The aetiology was as follows: Staphylococcus aureus, 19; Streptococcus spp., 14; Gram-negative bacilli, 12; anaerobes, two; and mixed infections, three. Thirty-four (68%) patients were treated with a conservative surgical approach (CSA) with implant retention, and 16 had prosthesis removal. At 2-year follow-up, 24 (48%) were cured, seven (14%) had relapsed, seven (14%) had died, five (10%) had persistent infection, five had re-infection, and two had an unknown evolution. Overall, the treatment failure rates were 57.8% in staphylococcal infections and 14.3% in streptococcal infections. There were no failures in patients with Gram-negative bacillary. By multivariate analysis, CSA was the only factor independently associated with treatment failure (OR 11.6; 95% CI 1.29-104.8). We were unable to identify any factors predicting treatment failure in CSA patients, although a Gram-negative bacillary aetiology was a protective factor. These data suggest that although conservative surgery was the only factor independently associated with treatment failure, it could be the first therapeutic choice for the management of Gram-negative bacillary and streptococcal AHPJI, and for some cases with acute S. aureus infections.
Resumo:
BACKGROUND Based on the mechanism of action, combining somatostatin analogues (SSAs) with mTOR inhibitors or antiangiogenic agents may provide synergistic effects for the treatment of patients with neuroendocrine tumours (NETs). Herein, we investigate the use of these treatment combinations in clinical practice. METHODS This retrospective cross-sectional analysis of patients with NETs treated with the SSA lanreotide and targeted therapies at 35 Spanish hospitals evaluated the efficacy and safety of lanreotide treatment combinations in clinical practice. The data of 159 treatment combinations with lanreotide in 133 patients was retrospectively collected. RESULTS Of the 133 patients, with a median age of 59.4 (16-83) years, 70 (52.6 %) patients were male, 64 (48.1 %) had pancreatic NET, 23 (17.3 %) had ECOG PS ≥2, 41 (30.8 %) had functioning tumours, 63 (47.7 %) underwent surgery of the primary tumour, 45 (33.8 %) had received prior chemotherapy, and 115 (86.5 %) had received prior SSAs. 115 patients received 1 lanreotide treatment combination and 18 patients received between 2 and 5 combinations. Lanreotide was mainly administered in combination with everolimus (73 combinations) or sunitinib (61 combinations). The probability of being progression-free was 78.5 % (6 months), 68.6 % (12 months) and 57.0 % (18 months) for patients who only received everolimus plus lanreotide (n = 57) and 89.3 % (6 months), 73.0 % (12 months), and 67.4 % (18 months) for patients who only received sunitinib and lanreotide (n = 50). In patients who only received everolimus plus lanreotide the median time-to-progression from the initiation of lanreotide combination treatment was 25.8 months (95 % CI, 11.3, 40.3) and it had not yet been reached among the subgroup of patients only receiving sunitinib plus lanreotide. The safety profile of the combination treatment was comparable to that of the targeted agent alone. CONCLUSIONS The combination of lanreotide and targeted therapies, mainly everolimus and sunitinib, is widely used in clinical practice without unexpected toxicities and suggests efficacy that should be explored in randomized prospective clinical trials.
Resumo:
We present the first evaluation of a novel molecular assay, the Speed-oligo Direct Mycobacterium tuberculosis (SO-DMT) assay, which is based on PCR combined with a dipstick for the detection of mycobacteria and the specific identification of M. tuberculosis complex (MTC) in respiratory specimens. A blind evaluation was carried out in two stages: first, under experimental conditions on convenience samples comprising 20 negative specimens, 44 smear- and culture-positive respiratory specimens, and 11 sputa inoculated with various mycobacterium-related organisms; and second, in the routine workflow of 566 fresh respiratory specimens (4.9% acid-fast bacillus [AFB] smear positives, 7.6% MTC positives, and 1.8% nontuberculous mycobacteria [NTM] culture positives) from two Mycobacterium laboratories. SO-DMT assay showed no reactivity in any of the mycobacterium-free specimens or in those with mycobacterium-related organisms. Compared to culture, the sensitivity in the selected smear-positive specimens was 0.91 (0.92 for MTC and 0.90 for NTM), and there was no molecular detection of NTM in a tuberculosis case or vice versa. With respect to culture and clinical data, the sensitivity, specificity, and positive and negative predictive values for the SO-DMT system in routine specimens were 0.76 (0.93 in smear positives [1.0 for MTC and 0.5 for NTM] and 0.56 in smear negatives [0.68 for MTC and 0.16 for NTM]), 0.99, 0.85 (1.00 in smear positives and 0.68 in smear negatives), and 0.97, respectively. Molecular misidentification of NTM cases occurred when testing 2 gastric aspirates from two children with clinically but not microbiologically confirmed lung tuberculosis. The SO-DMT assay appears to be a fast and easy alternative for detecting mycobacteria and differentiating MTC from NTM in smear-positive respiratory specimens.
Resumo:
BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.