11 resultados para Dolichos lab lab


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Obesity is the most frequent metabolic disease in the World, and is associated with several comorbidities. Bariatric procedures arise as a promising treatment when classical approach is ineffective. Half of the operated patients are reproductive-aged women and there is evidence that obesity is related to worse maternal and fetal outcomes. Because nutritional status is affected by bariatric surgery and is a vital component during pregnancy, the aim of our study is to asses the impact of bariatric surgery on pregnancy in these patients. MATERIAL AND METHODS We studied 10 women and 15 pregnancies following bariatric surgery between 2003 and 2009. The visits took place every three months by an obstetrician and an endocrinologist with experience in nutrition, recording clinical features and lab work. RESULTS We found iron deficiency in 80% of the pregnancies, vitamin D in 46,7%, vitamin A in 20%, vitamin E in 13,3% and vitamin B12 in 26,7%. There were no complications during pregnancy, except one case of gravidic hiperemesis. There were nine deliveries without malformations, three of them were small for gestational age newborns and one suffered aspiration pneumonia. There were three stillbirths and one preterm delivery with fetal death. CONCLUSIONS our results show fewer complications during pregnancy in these women than obese women and similar to general population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Only multifaceted hospital wide interventions have been successful in achieving sustained improvements in hand hygiene (HH) compliance. METHODOLOGY/PRINCIPAL FINDINGS Pre-post intervention study of HH performance at baseline (October 2007-December 2009) and during intervention, which included two phases. Phase 1 (2010) included multimodal WHO approach. Phase 2 (2011) added Continuous Quality Improvement (CQI) tools and was based on: a) Increase of alcohol hand rub (AHR) solution placement (from 0.57 dispensers/bed to 1.56); b) Increase in frequency of audits (three days every three weeks: "3/3 strategy"); c) Implementation of a standardized register form of HH corrective actions; d) Statistical Process Control (SPC) as time series analysis methodology through appropriate control charts. During the intervention period we performed 819 scheduled direct observation audits which provided data from 11,714 HH opportunities. The most remarkable findings were: a) significant improvements in HH compliance with respect to baseline (25% mean increase); b) sustained high level (82%) of HH compliance during intervention; c) significant increase in AHRs consumption over time; c) significant decrease in the rate of healthcare-acquired MRSA; d) small but significant improvements in HH compliance when comparing phase 2 to phase 1 [79.5% (95% CI: 78.2-80.7) vs 84.6% (95% CI:83.8-85.4), p<0.05]; e) successful use of control charts to identify significant negative and positive deviations (special causes) related to the HH compliance process over time ("positive": 90.1% as highest HH compliance coinciding with the "World hygiene day"; and "negative":73.7% as lowest HH compliance coinciding with a statutory lay-off proceeding). CONCLUSIONS/SIGNIFICANCE CQI tools may be a key addition to WHO strategy to maintain a good HH performance over time. In addition, SPC has shown to be a powerful methodology to detect special causes in HH performance (positive and negative) and to help establishing adequate feedback to healthcare workers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Preanalytical mistakes (PAMs) in samples usually led to rejection upon arrival to the clinical laboratory. However, PAMs might not always be detected and result in clinical problems. Thus, PAMs should be minimized. We detected PAMs in samples from Primary Health Care Centres (PHCC) served by our central laboratory. Thus, the goal of this study was to describe the number and types of PAMs, and to suggest some strategies for improvement. METHODS The presence of PAMs, as sample rejection criteria, in samples submitted from PHCC to our laboratory during October and November 2007 was retrospectively analysed. RESULTS Overall, 3885 PAMs (7.4%) were detected from 52,669 samples for blood analyses. This included missed samples (n=1763; 45.4% of all PAMs, 3.3% of all samples), haemolysed samples (n=1408; 36.2% and 2.7%, respectively), coagulated samples (n=391; 10% and 0.7%, respectively), incorrect sample volume (n=110; 2.8% and 0.2%, respectively), and others (n=213; 5.5% and 0.4%, respectively). For urine samples (n=18,852), 1567 of the samples were missing (8.3%). CONCLUSIONS We found the proportion of PAMs in blood and urine samples to be 3-fold higher than that reported in the literature. Therefore, strategies for improvement directed towards the staff involved, as well as an exhaustive audit of preanalytical process are needed. To attain this goal, we first implemented a continued education programme, financed by our Regional Health Service and focused in Primary Care Nurses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been estimated that more than 70% of all medical activity is directly related to information providing analytical data. Substantial technological advances have taken place recently, which have allowed a previously unimagined number of analytical samples to be processed while offering high quality results. Concurrently, yet more new diagnostic determinations have been introduced - all of which has led to a significant increase in the prescription of analytical parameters. This increased workload has placed great pressure on the laboratory with respect to health costs. The present manager of the Clinical Laboratory (CL) has had to examine cost control as well as rationing - meaning that the CL's focus has not been strictly metrological, as if it were purely a system producing results, but instead has had to concentrate on its efficiency and efficacy. By applying re-engineering criteria, an emphasis has had to be placed on improved organisation and operating practice within the CL, focussing on the current criteria of the Integrated Management Areas where the technical and human resources are brought together. This re-engineering has been based on the concepts of consolidating and integrating the analytical platforms, while differentiating the production areas (CORE Laboratory) from the information areas. With these present concepts in mind, automation and virological treatment, along with serology in general, follow the same criteria as the rest of the operating methodology in the Clinical Laboratory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background A high level of red blood cell distribution width (RDW) is a novel prognostic marker that may reflect an underlying inflammatory state. It has recently shown that when increased, it is related to cardiovascular disease, mortality, and metabolic syndrome (MetS) in the general population. Objectives To analyse the potential relation between high levels of RDW and cardiovascular risk (CVR) and MetS in HIVpatients. Patients and methods Observational, cross-sectional study of a series of HIVoutpatients attended in our Hospital. Demographic, anthropometric, clinical, and fasting lab data were recorded in all cases. CVR at 10 years was evaluated by Framingham equation, and MetS diagnosed according to the National Cholesterol Education Program criteria. Statistic program: SPSS 17.0. Results 666 patients were included, 79.3% were men, and mean age was 44.7 years. Mean CD4 count was 506 cells/ mm3 , 87.5% of the patients were on antiretroviral therapy, and 85.3% had undetectable HIV viral load. Mean RDW was 13.07% (range: 7.7-33.6%; 75th percentile 14,1%), with a prevalence of MetS of 15.7, 9.3, 18.8 and 16.6% first through fourth RDW quartile, and of patients with CVR >20% of 8.4, 4.0, 4.4 and 6.4%, respectively (p>0,05). The highest quartile of RDW (>14.1%) was associated with AIDS (OR 1.6, 95%CI 1.0-2.4; p 0.02), detectable HIV viral load (OR 1.5, 95%CI 1.01-2.4; p 0.04), and hypertension (OR 2.3, 95%CI 1.4-4.0; p 0.001). Conclusions In HIV-infected outpatients, higher RDW is related with detectable HIV viral load and with AIDS. Although it was associated with a traditional CVR factor as hypertension, we found no relation with MetS nor with higher CVR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A workshop was convened to discuss best practices for the assessment of drug-induced liver injury (DILI) in clinical trials. In a breakout session, workshop attendees discussed necessary data elements and standards for the accurate measurement of DILI risk associated with new therapeutic agents in clinical trials. There was agreement that in order to achieve this goal the systematic acquisition of protocol-specified clinical measures and lab specimens from all study subjects is crucial. In addition, standard DILI terms that address the diverse clinical and pathologic signatures of DILI were considered essential. There was a strong consensus that clinical and lab analyses necessary for the evaluation of cases of acute liver injury should be consistent with the US Food and Drug Administration (FDA) guidance on pre-marketing risk assessment of DILI in clinical trials issued in 2009. A recommendation that liver injury case review and management be guided by clinicians with hepatologic expertise was made. Of note, there was agreement that emerging DILI signals should prompt the systematic collection of candidate pharmacogenomic, proteomic and/or metabonomic biomarkers from all study subjects. The use of emerging standardized clinical terminology, CRFs and graphic tools for data review to enable harmonization across clinical trials was strongly encouraged. Many of the recommendations made in the breakout session are in alignment with those made in the other parallel sessions on methodology to assess clinical liver safety data, causality assessment for suspected DILI, and liver safety assessment in special populations (hepatitis B, C, and oncology trials). Nonetheless, a few outstanding issues remain for future consideration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper introduces the evaluation report after fostering a Standard-based Interoperability Framework (SIF) between the Virgen del Rocío University Hospital (VRUH) Haemodialysis (HD) Unit and 5 outsourced HD centres in order to improve integrated care by automatically sharing patients' Electronic Health Record (EHR) and lab test reports. A pre-post study was conducted during fourteen months. The number of lab test reports of both emergency and routine nature regarding to 379 outpatients was computed before and after the integration of the SIF. Before fostering SIF, 19.38 lab tests per patient were shared between VRUH and HD centres, 5.52 of them were of emergency nature while 13.85 were routine. After integrating SIF, 17.98 lab tests per patient were shared, 3.82 of them were of emergency nature while 14.16 were routine. The inclusion of a SIF in the HD Integrated Care Process has led to an average reduction of 1.39 (p=0.775) lab test requests per patient, including a reduction of 1.70 (p=0.084) in those of emergency nature, whereas an increase of 0.31 (p=0.062) was observed in routine lab tests. Fostering this strategy has led to the reduction in emergency lab test requests, which implies a potential improvement of the integrated care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: APACHE-II IS a score, based on several clinical and analytical measurements within 24 hours of admission in Intensive Care Unit (ICU). C-Reactive Protein (CRP), Lactate and recently Procalcitonin (PCT), also are biomarkers for the assessment of septic patients. The aim of this study was to find out if CRP, lactate and PCT during the first 24 hours from severe sepsis or septic shock onset, improved prediction of the APACHE II in terms of prognosis. Conclusions: CRP improves the prediction of patients with sepsis used in conjunction with the APACHE II score in severe sepsis and, lactate along with the CRP are the best precictors of survival in the cases of septic shock. The PCT did not show any predictive value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The glycosylated hemoglobin (HbA1c) is used to help monitor the degree of a diabetic’s hyperglycemia. Security and accuracy of the methods used in its detection are affected by variants forms of Hb or elevations in levels of Fetal Hb (HbF). These interference are the result of a change in the haemoglobin total net charge of the variant due of a substitution of one amino acid in the remaining amino terminal of the beta chain. International Standardization for HbA1c values (NGSP) not include interference assessment as part of the certification program. Therefore, the effect of each variant or the lifting of the HbF on HbA1c result should be examined in each sample depending on the detected variant and the method used for the detection of the same. The objectives were: to describe the possible variants of Hb and their interference in HbA1c measurement by our method, after the implementation of a computer program for their detection. To identify some variants detected by chromatography liquid ion exchange high resolution (HPLC) with DNA molecular sequencing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The serum and urine proteins responsible for enhanced pigment production in Streptococcus agalactiae in culture media were purified by chromatography and were identified as amylases by comparison of their amino acid composition with that calculated for proteins with known sequences. Similar pigment-enhancing activity was displayed by other amylases of nonanimal origin and by maltooligosaccharides.