10 resultados para Diagnósticos territoriales


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 75-year-old man diagnosed with lower esophageal adenocarcinoma suffered from epirubicin extravasation during the second cycle of neoadjuvant chemotherapy with epirubicin and oxaliplatin. A full recovery was achieved after treatment with dexrazoxane (Cardioxane® ). This is the first time in our hospital that extravasation of an anthracycline has been treated with dexrazoxane. We used Cardioxane® , approved for the prevention of anthracycline-induced cardiotoxicity, while Savene® is indicated for the treatment of anthracycline extravasation. The treatment was effective, and the selection of Cardioxane® (seven-fold cheaper than Savene® ) yielded a cost saving. Consequently, Cardioxane® has been included in our guidelines for anthracycline extravasation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En la port.: Dirección General de Planificación e Innovación Sanitaria, Servicio de Conciertos Sanitarios

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND. The phenomenon of misdiagnosing tuberculosis (TB) by laboratory cross-contamination when culturing Mycobacterium tuberculosis (MTB) has been widely reported and it has an obvious clinical, therapeutic and social impact. The final confirmation of a cross-contamination event requires the molecular identification of the same MTB strain cultured from both the potential source of the contamination and from the false-positive candidate. The molecular tool usually applied in this context is IS6110-RFLP which takes a long time to provide an answer, usually longer than is acceptable for microbiologists and clinicians to make decisions. Our purpose in this study is to evaluate a novel PCR-based method, MIRU-VNTR as an alternative to assure a rapid and optimized analysis of cross-contamination alerts. RESULTS. MIRU-VNTR was prospectively compared with IS6110-RFLP for clarifying 19 alerts of false positivity from other laboratories. MIRU-VNTR highly correlated with IS6110-RFLP, reduced the response time by 27 days and clarified six alerts unresolved by RFLP. Additionally, MIRU-VNTR revealed complex situations such as contamination events involving polyclonal isolates and a false-positive case due to the simultaneous cross-contamination from two independent sources. CONCLUSION. Unlike standard RFLP-based genotyping, MIRU-VNTR i) could help reduce the impact of a false positive diagnosis of TB, ii) increased the number of events that could be solved and iii) revealed the complexity of some cross-contamination events that could not be dissected by IS6110-RFLP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Laboratory cross-contamination by Mycobacterium tuberculosis is known to be responsible for the misdiagnosis of tuberculosis, but its impact on other contexts has not been analyzed. We present the findings of a molecular epidemiology analysis in which the recent transmission events identified by a genotyping reference center were overestimated as a result of unnoticed laboratory cross-contamination in the original diagnostic laboratories.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Preanalytical mistakes (PAMs) in samples usually led to rejection upon arrival to the clinical laboratory. However, PAMs might not always be detected and result in clinical problems. Thus, PAMs should be minimized. We detected PAMs in samples from Primary Health Care Centres (PHCC) served by our central laboratory. Thus, the goal of this study was to describe the number and types of PAMs, and to suggest some strategies for improvement. METHODS The presence of PAMs, as sample rejection criteria, in samples submitted from PHCC to our laboratory during October and November 2007 was retrospectively analysed. RESULTS Overall, 3885 PAMs (7.4%) were detected from 52,669 samples for blood analyses. This included missed samples (n=1763; 45.4% of all PAMs, 3.3% of all samples), haemolysed samples (n=1408; 36.2% and 2.7%, respectively), coagulated samples (n=391; 10% and 0.7%, respectively), incorrect sample volume (n=110; 2.8% and 0.2%, respectively), and others (n=213; 5.5% and 0.4%, respectively). For urine samples (n=18,852), 1567 of the samples were missing (8.3%). CONCLUSIONS We found the proportion of PAMs in blood and urine samples to be 3-fold higher than that reported in the literature. Therefore, strategies for improvement directed towards the staff involved, as well as an exhaustive audit of preanalytical process are needed. To attain this goal, we first implemented a continued education programme, financed by our Regional Health Service and focused in Primary Care Nurses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The accuracy of the MicroScan WalkAway, BD Phoenix, and Vitek-2 systems for susceptibility testing of quinolones and aminoglycosides against 68 enterobacteria containing qnrB, qnrS, and/or aac(6 ')-Ib-cr was evaluated using reference microdilution. Overall, one very major error (0.09%), 6 major errors (0.52%), and 45 minor errors (3.89%) were noted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Missed, delayed or incorrect diagnoses are considered to be diagnostic errors. The aim of this paper is to describe the methodology of a study to analyse cognitive aspects of the process by which primary care (PC) physicians diagnose dyspnoea. It examines the possible links between the use of heuristics, suboptimal cognitive acts and diagnostic errors, using Reason's taxonomy of human error (slips, lapses, mistakes and violations). The influence of situational factors (professional experience, perceived overwork and fatigue) is also analysed. METHODS Cohort study of new episodes of dyspnoea in patients receiving care from family physicians and residents at PC centres in Granada (Spain). With an initial expected diagnostic error rate of 20%, and a sampling error of 3%, 384 episodes of dyspnoea are calculated to be required. In addition to filling out the electronic medical record of the patients attended, each physician fills out 2 specially designed questionnaires about the diagnostic process performed in each case of dyspnoea. The first questionnaire includes questions on the physician's initial diagnostic impression, the 3 most likely diagnoses (in order of likelihood), and the diagnosis reached after the initial medical history and physical examination. It also includes items on the physicians' perceived overwork and fatigue during patient care. The second questionnaire records the confirmed diagnosis once it is reached. The complete diagnostic process is peer-reviewed to identify and classify the diagnostic errors. The possible use of heuristics of representativeness, availability, and anchoring and adjustment in each diagnostic process is also analysed. Each audit is reviewed with the physician responsible for the diagnostic process. Finally, logistic regression models are used to determine if there are differences in the diagnostic error variables based on the heuristics identified. DISCUSSION This work sets out a new approach to studying the diagnostic decision-making process in PC, taking advantage of new technologies which allow immediate recording of the decision-making process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The elderly population is particularly at risk for developing vitamin B12-deficiency. Serum cobalamin does not necessarily reflect a normal B12 status. The determination of methylmalonic acid is not available in all laboratories. Issues of sensitivity for holotranscobalamin and the low specificity of total homocysteine limit their utility. The aim of the present study is to establish a diagnostic algorithm by using a combination of these markers in place of a single measurement. METHODS: We compared the diagnostic efficiency of these markers for detection of vitamin B12 deficiency in a population (n = 218) of institutionalized elderly (median age 80 years). Biochemical, haematological and morphological data were used to categorize people with or without vitamin B12 deficiency. RESULTS: In receiver operating curves characteristics for detection on vitamin B12 deficiency using single measurements, serum folate has the greatest area under the curve (0.87) and homocysteine the lowest (0.67). The best specificity was observed for erythrocyte folate and methylmalonic acid (100% for both) but their sensitivity was very low (17% and 53%, respectively). The highest sensitivity was observed for homocysteine (81%) and serum folate (74%). When we combined these markers, starting with serum and erythrocyte folate, followed by holotranscobalamin and ending by methylmalonic acid measurements, the overall sensitivity and specificity of the algorithm were 100% and 90%, respectively. CONCLUSION: The proposed algorithm, which combines erythrocyte folate, serum folate, holotranscobalamin and methylmalonic acid, but eliminate B12 and tHcy measurements, is a useful alternative for vitamin B12 deficiency screening in an elderly institutionalized cohort.