4 resultados para Detection, Optimisation, Assessment, Highway


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper addresses a fully automatic landmarks detection method for breast reconstruction aesthetic assessment. The set of landmarks detected are the supraesternal notch (SSN), armpits, nipples, and inframammary fold (IMF). These landmarks are commonly used in order to perform anthropometric measurements for aesthetic assessment. The methodological approach is based on both illumination and morphological analysis. The proposed method has been tested with 21 images. A good overall performance is observed, although several improvements must be achieved in order to refine the detection of nipples and SSNs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study is part of an ongoing collaborative effort between the medical and the signal processing communities to promote research on applying standard Automatic Speech Recognition (ASR) techniques for the automatic diagnosis of patients with severe obstructive sleep apnoea (OSA). Early detection of severe apnoea cases is important so that patients can receive early treatment. Effective ASR-based detection could dramatically cut medical testing time. Working with a carefully designed speech database of healthy and apnoea subjects, we describe an acoustic search for distinctive apnoea voice characteristics. We also study abnormal nasalization in OSA patients by modelling vowels in nasal and nonnasal phonetic contexts using Gaussian Mixture Model (GMM) pattern recognition on speech spectra. Finally, we present experimental findings regarding the discriminative power of GMMs applied to severe apnoea detection. We have achieved an 81% correct classification rate, which is very promising and underpins the interest in this line of inquiry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The high prevalence of disease-related hospital malnutrition justifies the need for screening tools and early detection in patients at risk for malnutrition, followed by an assessment targeted towards diagnosis and treatment. At the same time there is clear undercoding of malnutrition diagnoses and the procedures to correct it Objectives: To describe the INFORNUT program/ process and its development as an information system. To quantify performance in its different phases. To cite other tools used as a coding source. To calculate the coding rates for malnutrition diagnoses and related procedures. To show the relationship to Mean Stay, Mortality Rate and Urgent Readmission; as well as to quantify its impact on the hospital Complexity Index and its effect on the justification of Hospitalization Costs. Material and methods: The INFORNUT® process is based on an automated screening program of systematic detection and early identification of malnourished patients on hospital admission, as well as their assessment, diagnoses, documentation and reporting. Of total readmissions with stays longer than three days incurred in 2008 and 2010, we recorded patients who underwent analytical screening with an alert for a medium or high risk of malnutrition, as well as the subgroup of patients in whom we were able to administer the complete INFORNUT® process, generating a report for each.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The glycosylated hemoglobin (HbA1c) is used to help monitor the degree of a diabetic’s hyperglycemia. Security and accuracy of the methods used in its detection are affected by variants forms of Hb or elevations in levels of Fetal Hb (HbF). These interference are the result of a change in the haemoglobin total net charge of the variant due of a substitution of one amino acid in the remaining amino terminal of the beta chain. International Standardization for HbA1c values (NGSP) not include interference assessment as part of the certification program. Therefore, the effect of each variant or the lifting of the HbF on HbA1c result should be examined in each sample depending on the detected variant and the method used for the detection of the same. The objectives were: to describe the possible variants of Hb and their interference in HbA1c measurement by our method, after the implementation of a computer program for their detection. To identify some variants detected by chromatography liquid ion exchange high resolution (HPLC) with DNA molecular sequencing.