2 resultados para DETERIORO CONGNITIVO


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Current high survival in hemodialysis patients (52% at 5 years) have made the chronic manifestations to emerge such as the high hyponutrition prevalence of these patients, as well as the importance of the nutritional status in their morbimortality. The reason for protein-caloric hyponutrition is multifactorial, although chronic inflammatory conditions associated to the dialysis technique are becoming more and more relevant. The variations in several nutritional biochemical parameters (total proteins, plasma albumin, transferrin, and total cholesterol) have been assessed in 73 hemodialysis patients for one year. The mean age of the patients was 53.3 +/- 18.69 years (43 males and 30 females). The average on hemodialysis program was 43 +/- 33 months, with a mean session duration of 246 +/- 24 minutes, and mean hemodialysis dose administered of 1.37 +/- 0.27 (KT/V) (second generation Daurgidas). A decrease in all the biochemical parameters assessed has been observed, with statistically significant differences: total proteins (p < 0.001), albumin (p < 0.00001), total cholesterol (p < 0.05), and transferrin (p < 0.01). The evolution of the nutritional biochemical parameters assessed showed an important nutritional deterioration of the patients remaining stable with the therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. To study the utility of the Mini-Cog test for detection of patients with cognitive impairment (CI) in primary care (PC). Methods. We pooled data from two phase III studies conducted in Spain. Patients with complaints or suspicion of CI were consecutively recruited by PC physicians. The cognitive diagnosis was performed by an expert neurologist, after formal neuropsychological evaluation. The Mini-Cog score was calculated post hoc, and its diagnostic utility was evaluated and compared with the utility of the Mini-Mental State (MMS), the Clock Drawing Test (CDT), and the sum of the MMS and the CDT (MMS + CDT) using the area under the receiver operating characteristic curve (AUC). The best cut points were obtained on the basis of diagnostic accuracy (DA) and kappa index. Results. A total sample of 307 subjects (176 CI) was analyzed. The Mini-Cog displayed an AUC (±SE) of 0.78 ± 0.02, which was significantly inferior to the AUC of the CDT (0.84 ± 0.02), the MMS (0.84 ± 0.02), and the MMS + CDT (0.86 ± 0.02). The best cut point of the Mini-Cog was 1/2 (sensitivity 0.60, specificity 0.90, DA 0.73, and kappa index 0.48 ± 0.05). Conclusions. The utility of the Mini-Cog for detection of CI in PC was very modest, clearly inferior to the MMS or the CDT. These results do not permit recommendation of the Mini-Cog in PC.