6 resultados para Cromatografía por intercambio Iónico


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The glycosylated hemoglobin (HbA1c) is used to help monitor the degree of a diabetic’s hyperglycemia. Security and accuracy of the methods used in its detection are affected by variants forms of Hb or elevations in levels of Fetal Hb (HbF). These interference are the result of a change in the haemoglobin total net charge of the variant due of a substitution of one amino acid in the remaining amino terminal of the beta chain. International Standardization for HbA1c values (NGSP) not include interference assessment as part of the certification program. Therefore, the effect of each variant or the lifting of the HbF on HbA1c result should be examined in each sample depending on the detected variant and the method used for the detection of the same. The objectives were: to describe the possible variants of Hb and their interference in HbA1c measurement by our method, after the implementation of a computer program for their detection. To identify some variants detected by chromatography liquid ion exchange high resolution (HPLC) with DNA molecular sequencing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are exceptional situations where emergency services are required Primary Care in the application of material used by drug-dependent patients, being the response to this demand is something that many of the cases, to individual discretion and the randomness and variability every situation leads to an answer. It calls for a response commensurate to public services and preventive health philosophy in most cases will be carried out by the nurse to perform assistance Devices Critical Care (DCCU), often this first contact these patients and slots at the supply of resources diminishes the possibilities of acquisition of such material to them. That is why, and in the absence in this area of patient safety and professional, a workflow model and according to the prevailing philosophy of working in primary care in terms of prevention policies and recruitment of patients concerned, this project raises guidance for the development of a needle exchange program from the triage consultations DCCU.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new oligochromatographic assay, Speed-Oligo Novel Influenza A H1N1, was designed and optimized for the specific detection of the 2009 influenza A H1N1 virus. The assay is based on a PCR method coupled to detection of PCR products by means of a dipstick device. The target sequence is a 103-bp fragment within the hemagglutinin gene. The analytical sensitivity of the new assay was measured with serial dilutions of a plasmid that contained the target sequence, and we determined that down to one copy per reaction of the plasmid was reliably detected. Diagnostic performance was assessed with 103 RNAs from suspected cases (40 positive and 63 negative results) previously analyzed with a reference real-time PCR technique. All positive cases were confirmed, and no false-positive results were detected with the new assay. No cross-reactions were observed when other viral strains or clinical samples with other respiratory viruses were tested. According to these results, this new assay has 100% sensitivity and specificity. The turnaround time for the whole procedure was 140 min. The assay may be especially useful for the specific detection of 2009 H1N1 virus in laboratories not equipped with real-time PCR instruments

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION We functionally analyzed a frameshift mutation in the SCN5A gene encoding cardiac Na(+) channels (Nav1.5) found in a proband with repeated episodes of ventricular fibrillation who presented bradycardia and paroxysmal atrial fibrillation. Seven relatives also carry the mutation and showed a Brugada syndrome with an incomplete and variable expression. The mutation (p.D1816VfsX7) resulted in a severe truncation (201 residues) of the Nav1.5 C-terminus. METHODS AND RESULTS Wild-type (WT) and mutated Nav1.5 channels together with hNavβ1 were expressed in CHO cells and currents were recorded at room temperature using the whole-cell patch-clamp. Expression of p.D1816VfsX7 alone resulted in a marked reduction (≈90%) in peak Na(+) current density compared with WT channels. Peak current density generated by p.D1816VfsX7+WT was ≈50% of that generated by WT channels. p.D1816VfsX7 positively shifted activation and inactivation curves, leading to a significant reduction of the window current. The mutation accelerated current activation and reactivation kinetics and increased the fraction of channels developing slow inactivation with prolonged depolarizations. However, late INa was not modified by the mutation. p.D1816VfsX7 produced a marked reduction of channel trafficking toward the membrane that was not restored by decreasing incubation temperature during cell culture or by incubation with 300 μM mexiletine and 5 mM 4-phenylbutirate. CONCLUSION Despite a severe truncation of the C-terminus, the resulting mutated channels generate currents, albeit with reduced amplitude and altered biophysical properties, confirming the key role of the C-terminal domain in the expression and function of the cardiac Na(+) channel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gluten content from barley, rye, wheat and in certain oat varieties, must be avoid in individuals with celiac disease. In most of the Western countries, the level of gluten content in food to be considered as gluten-free products is below 20 parts per million measured by ELISA based on specific anti-gluten peptide antibody. However, in beverages or food suffering complex hydrolytic processes as beers, the relative proportion of reactive peptides for celiac patients and the analytical techniques may differ, because of the diversity of the resulting peptide populations after fermentations. A beer below 20 parts per million of gluten but yet detectable levels of gluten peptides by anti-gliadin 33-mer antibodies (G12 and A1) was analyzed. We identified and characterized the relevant peptides for either antibody recognition or immunoactivity in celiac patients. The beer was fractionated by HPLC. The relative reactivity of the different HPLC fractions to the G12/A1 antibodies correlated to the reactivity of peripheral blood mononuclear cells isolated from 14 celiac individuals. Peptides from representative fractions classified according to the relative reactivity to G12/A1 antibodies were identified by mass spectrometry. The beer peptides containing sequences with similarity to those of previously described G12 and A1 epitopes were synthesized and confirmed significant reactivity for the antibodies. The most reactive peptides for G12/A1 also confirmed the highest immunogenicity by peripheral blood mononuclear cell activation and interferon γ production from celiac patients. We concluded that preparative HPLC combined with anti-gliadin 33-mer G12/A1 antibodies were very sensitive and specific methods to analyze the relevant immunogenic peptides in hydrolyzed gluten.