2 resultados para Combines


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Challenges exist in the clinical diagnosis of drug-induced liver injury (DILI) and in obtaining information on hepatotoxicity in humans. OBJECTIVE (i) To develop a unified list that combines drugs incriminated in well vetted or adjudicated DILI cases from many recognized sources and drugs that have been subjected to serious regulatory actions due to hepatotoxicity; and (ii) to supplement the drug list with data on reporting frequencies of liver events in the WHO individual case safety report database (VigiBase). DATA SOURCES AND EXTRACTION (i) Drugs identified as causes of DILI at three major DILI registries; (ii) drugs identified as causes of drug-induced acute liver failure (ALF) in six different data sources, including major ALF registries and previously published ALF studies; and (iii) drugs identified as being subjected to serious governmental regulatory actions due to their hepatotoxicity in Europe or the US were collected. The reporting frequency of adverse events was determined using VigiBase, computed as Empirical Bayes Geometric Mean (EBGM) with 90% confidence interval for two customized terms, 'overall liver injury' and 'ALF'. EBGM of >or=2 was considered a disproportional increase in reporting frequency. The identified drugs were then characterized in terms of regional divergence, published case reports, serious regulatory actions, and reporting frequency of 'overall liver injury' and 'ALF' calculated from VigiBase. DATA SYNTHESIS After excluding herbs, supplements and alternative medicines, a total of 385 individual drugs were identified; 319 drugs were identified in the three DILI registries, 107 from the six ALF registries (or studies) and 47 drugs that were subjected to suspension or withdrawal in the US or Europe due to their hepatotoxicity. The identified drugs varied significantly between Spain, the US and Sweden. Of the 319 drugs identified in the DILI registries of adjudicated cases, 93.4% were found in published case reports, 1.9% were suspended or withdrawn due to hepatotoxicity and 25.7% were also identified in the ALF registries/studies. In VigiBase, 30.4% of the 319 drugs were associated with disproportionally higher reporting frequency of 'overall liver injury' and 83.1% were associated with at least one reported case of ALF. CONCLUSIONS This newly developed list of drugs associated with hepatotoxicity and the multifaceted analysis on hepatotoxicity will aid in causality assessment and clinical diagnosis of DILI and will provide a basis for further characterization of hepatotoxicity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The elderly population is particularly at risk for developing vitamin B12-deficiency. Serum cobalamin does not necessarily reflect a normal B12 status. The determination of methylmalonic acid is not available in all laboratories. Issues of sensitivity for holotranscobalamin and the low specificity of total homocysteine limit their utility. The aim of the present study is to establish a diagnostic algorithm by using a combination of these markers in place of a single measurement. METHODS: We compared the diagnostic efficiency of these markers for detection of vitamin B12 deficiency in a population (n = 218) of institutionalized elderly (median age 80 years). Biochemical, haematological and morphological data were used to categorize people with or without vitamin B12 deficiency. RESULTS: In receiver operating curves characteristics for detection on vitamin B12 deficiency using single measurements, serum folate has the greatest area under the curve (0.87) and homocysteine the lowest (0.67). The best specificity was observed for erythrocyte folate and methylmalonic acid (100% for both) but their sensitivity was very low (17% and 53%, respectively). The highest sensitivity was observed for homocysteine (81%) and serum folate (74%). When we combined these markers, starting with serum and erythrocyte folate, followed by holotranscobalamin and ending by methylmalonic acid measurements, the overall sensitivity and specificity of the algorithm were 100% and 90%, respectively. CONCLUSION: The proposed algorithm, which combines erythrocyte folate, serum folate, holotranscobalamin and methylmalonic acid, but eliminate B12 and tHcy measurements, is a useful alternative for vitamin B12 deficiency screening in an elderly institutionalized cohort.