2 resultados para Cola acuminata
Resumo:
The aim of this validation study was to assess the measurement properties of the CECA (Spanish acronym for the Specific Questionnaire for Condylomata Acuminata) in patients with anogenital condylomas. A total of 247 patients aged > 18 years completed the questionnaire on 2 occasions as well as the Dermatology Life Quality Index (DLQI). The CECA questionnaire showed good internal consistency (Cronbach's alpha values of 0.86 and 0.91 in the emotional and sexual activity dimensions) and good testretest reliability (intraclass correlation coefficient 0.76 emotional dimension, 0.82 sexual activity dimension). Patients with de novo lesions and those with more extensive lesions and larger number of warts showed poorer health-related quality of life. CECA and DLQI scores correlated moderately. Patients whose lesions cleared at follow-up or with a reduction of >or= 50% showed a better improvement of health-related quality of life. The CECA questionnaire is a valid, reliable and sensitive tool for the assessment of health-related quality of life in patients with anogenital warts.
Resumo:
BACKGROUND It is unknown if lack of polymer can provoke a different edge response in drug-eluting stents. The aim of this study was to compare edge vascular response between polymer-free paclitaxel-eluting stent (PF-PES) and polymer-based paclitaxel-eluting stents (PB-PES). METHODS AND RESULTS: A total of 165 eligible patients undergoing percutaneous coronary intervention were prospectively randomized 1:1 to receive either PF-PES or PB-PES. Those patients with paired intravascular ultrasound (IVUS) after procedure and at 9-month follow-up were included in this analysis.Seventy-six patients with 84 lesions, divided into PB-PES (38 patients, 41 lesions) and PF-PES groups (38 patients, 43 lesions) had paired post-procedure and 9-month follow-up IVUS and were therefore included in this substudy. There was a significant lumen decrease at the proximal edge of PF-PES (from 9.02±3.06 mm(2)to 8.47±3.05 mm(2); P=0.040), and a significant plaque increase at the distal edges of PF-PES (from 4.39±2.73 mm(2)to 4.78±2.63 mm(2); P=0.004). At the distal edge there was a significant plaque increase in the PF-PES compared to PB-PES (+8.0% vs. -0.6%, respectively; P=0.015) with subsequent lumen reduction (-5.2% vs. +6.0%, respectively; P=0.024). CONCLUSIONS PF-PES had significant plaque increase and lumen reduction at the distal edge as compared to PB-PES, probably due to difference in polymer-based drug-release kinetics between the 2 platforms.