77 resultados para burrow counting

em Universit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mitochondrial (M) and lipid droplet (L) volume density (vd) are often used in exercise research. Vd is the volume of muscle occupied by M and L. The means of calculating these percents are accomplished by applying a grid to a 2D image taken with transmission electron microscopy; however, it is not known which grid best predicts these values. PURPOSE: To determine the grid with the least variability of Mvd and Lvd in human skeletal muscle. METHODS: Muscle biopsies were taken from vastus lateralis of 10 healthy adults, trained (N=6) and untrained (N=4). Samples of 5-10mg were fixed in 2.5% glutaraldehyde and embedded in EPON. Longitudinal sections of 60 nm were cut and 20 images were taken at random at 33,000x magnification. Vd was calculated as the number of times M or L touched two intersecting grid lines (called a point) divided by the total number of points using 3 different sizes of grids with squares of 1000x1000nm sides (corresponding to 1µm2), 500x500nm (0.25µm2) and 250x250nm (0.0625µm2). Statistics included coefficient of variation (CV), 1 way-BS ANOVA and spearman correlations. RESULTS: Mean age was 67 ± 4 yo, mean VO2peak 2.29 ± 0.70 L/min and mean BMI 25.1 ± 3.7 kg/m2. Mean Mvd was 6.39% ± 0.71 for the 1000nm squares, 6.01% ± 0.70 for the 500nm and 6.37% ± 0.80 for the 250nm. Lvd was 1.28% ± 0.03 for the 1000nm, 1.41% ± 0.02 for the 500nm and 1.38% ± 0.02 for the 250nm. The mean CV of the three grids was 6.65% ±1.15 for Mvd with no significant differences between grids (P>0.05). Mean CV for Lvd was 13.83% ± 3.51, with a significant difference between the 1000nm squares and the two other grids (P<0.05). The 500nm squares grid showed the least variability between subjects. Mvd showed a positive correlation with VO2peak (r = 0.89, p < 0.05) but not with weight, height, or age. No correlations were found with Lvd. CONCLUSION: Different size grids have different variability in assessing skeletal muscle Mvd and Lvd. The grid size of 500x500nm (240 points) was more reliable than 1000x1000nm (56 points). 250x250nm (1023 points) did not show better reliability compared with the 500x500nm, but was more time consuming. Thus, choosing a grid with square size of 500x500nm seems the best option. This is particularly relevant as most grids used in the literature are either 100 points or 400 points without clear information on their square size.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the issue of double counting of health impacts in the context of cost of illness valuation. Double counting occurs when estimates are jointly used, which rely on valuation techniques that overlap. As a solution, we propose to limit the scope of each of the valuation method to a specific range of impacts. In order to limit the contingentvaluation method to the exclusive valuation of intangible costs, we propose a three steps approach : (1) leave the respondents free to valuate the consequences which matter to them, (2) elicit respondent's motivations, (3) control for the influence motivations have on elicited values. This procedure was applied in a Swiss contingent-valuation. An econometric treatment was applied in order to limit the scope of the estimates of the contingent valuation method to intangibles,therefore the possibility to a combination of methods with the risk of double-counting and underestimating costs being kept to a minimum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liquid scintillation counting (LSC) is one of the most widely used methods for determining the activity of 241Pu. One of the main challenges of this counting method is the efficiency calibration of the system for the low beta energies of 241Pu (Emax = 20.8 keV). In this paper we compare the two most frequently used methods, the CIEMAT/NIST efficiency tracing (CNET) method and the experimental quench correction curve method. Both methods proved to be reliable, and agree within their uncertainties, for the expected quenching conditions of the sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The radioactive concentrations of (166m)Ho, (134)Cs and (133)Ba solutions have been standardised using a 4πβ-4πγ coincidence counting system we have recently set up. The detection in the beta channel is performed using various geometries of a UPS-89 plastic scintillator optically coupled to a selected low-noise 1in. diameter photomultiplier tube. The light-tight thin capsule that encloses this beta detector is housed within the well of a 5in.×5in. NaI(Tl) monocrystal detector. The beta detection efficiency can be varied either by optical filtering or electronic discrimination when the electrons loose all their energy in the plastic scintillator. This 4πβ-4πγ coincidence system improves on our 4πβ(PC)-γ system in that its sample preparation is less labour intensive, it yields larger beta- and gamma-counting efficiencies thus enabling the standardisation of low activity sources with good statistics in reasonable time, and it makes standardising short-lived radionuclides easier. The resulting radioactive concentrations of (166m)Ho, (134)Cs and (133)Ba are found to agree with those measured with other primary measurement methods thus validating our 4πβ-4πγ coincidence counting system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Normal rats were injected intravenously with 131I- and 125I-labeled intact murine and chimeric mouse-human monoclonal antibodies directed against carcinoembryonic antigen or with the corresponding F(ab')2 fragments. At different times after injection, individual animals were killed and radioactivity of blood and major organs, including bones and bone marrow, was determined. Ratios comparing radioactivity concentration in different tissues with that of bone marrow were calculated and found to remain stable during several effective half-lives of the antibodies. Mean bone marrow radioactivity was 35% (range, 29%-40%) of that of blood and 126% (range, 108%-147%) of that of liver after injection of intact Mabs or F(ab')2 fragments. In nude rats bearing human colon carcinoma xenografts producing carcinoembryonic antigen, relative bone marrow radioactivity was slightly lower than that in normal rats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Goals: Adjuvant chemotherapy decisions in breast cancer are increasing based on the pathologist's assessment of the proliferation fraction in the tumor. Yet, how good and how reproducible are we pathologists at providing reliable Ki-67 readings on breast carcinomas. Exactly how to count and in which areas to count within a tumor remains inadequately standardized. The Swiss Working Group of Gyneco- and Breast Pathologists has tried to appreciate this dilemma and to propose ways to obtain more reproducible results.Methods: In a first phase, 5 pathologists evaluated Ki67 counts in 10 breast cancers by exact counting (500 cells) and by eyeballing. Pathologists were free to select the region in which Ki67 was evaluated. In a second phase 16 pathologists evaluated Ki-67 counts in 3 breast cancers also by exact counting and eyeballing, but in predefined fields of interest. In both phases, Ki67 was assessed in centrally immunostained slides (ZH) and on slides immunostained in the 11 participating laboratories. In a third phase, these same 16 pathologists were once again asked to read the 3 cases from phase 2, plus three new cases, and this time exact guidelines were provided as to what exactly is considered a Ki-67 positive nucleus.Results: Discordance of Ki67 assessment was due to each of the following 4 factors: (i) pathologists' divergent definitions of what counts as a positive nucleus (ii) the mode of assessment (counting vs. eyeballing), (iii) immunostaining technique/protocol/antibody, and (iv) the selection of the area in which to count.Conclusion: Providing guidelines as to where to count (representative field in the tumor periphery and omitting hot spots) and what nuclei to count (even faintly immunostained nuclei count as positive) reduces the discordance rates of Ki67 readings between pathologists. Laboratory technique is only of minor importance (even over a large antibody dilution range), and counting nuclei does not improve accuracy, but rather aggravates deviations from the group mean values.Disclosure of Interest: None Declared

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The diagnosis of malignant hematologic diseases has become increasingly complex during the last decade. It is based on the interpretation of results from different laboratory analyses, which range from microscopy to gene expression profiling. Recently, a method for the analysis of RNA phenotypes has been developed, the nCounter technology (Nanostring® Technologies), which allows for simultaneous quantification of hundreds of RNA molecules in biological samples. We evaluated this technique in a Swiss multi-center study on eighty-six samples from acute leukemia patients. METHODS: mRNA and protein profiles were established for normal peripheral blood and bone marrow samples. Signal intensities of the various tested antigens with surface expression were similar to those found in previously performed Affymetrix microarray analyses. Acute leukemia samples were analyzed for a set of twenty-two validated antigens and the Pearson Correlation Coefficient for nCounter and flow cytometry results was calculated. RESULTS: Highly significant values between 0.40 and 0.97 were found for the twenty-two antigens tested. A second correlation analysis performed on a per sample basis resulted in concordant results between flow cytometry and nCounter in 44-100% of the antigens tested (mean = 76%), depending on the number of blasts present in a sample, the homogeneity of the blast population, and the type of leukemia (AML or ALL). CONCLUSIONS: The nCounter technology allows for fast and easy depiction of a mRNA profile from hematologic samples. This technology has the potential to become a valuable tool for the diagnosis of acute leukemias, in addition to multi-color flow cytometry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 4πβ-γ coincidence counting method and its close relatives are widely used for the primary standardization of radioactivity. Both the general formalism and specific implementation of these methods have been well-documented. In particular, previous papers contain the extrapolation equations used for various decay schemes, methods for determining model parameters and, in some cases, tabulated uncertainty budgets. Two things often lacking from experimental reports are both the rationale for estimating uncertainties in a specific way and the details of exactly how a specific component of uncertainty was estimated. Furthermore, correlations among the components of uncertainty are rarely mentioned. To fill in these gaps, the present article shares the best-practices from a few practitioners of this craft. We explain and demonstrate with examples of how these approaches can be used to estimate the uncertainty of the reported massic activity. We describe uncertainties due to measurement variability, extrapolation functions, dead-time and resolving-time effects, gravimetric links, and nuclear and atomic data. Most importantly, a thorough understanding of the measurement system and its response to the decay under study can be used to derive a robust estimate of the measurement uncertainty.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fractal geometry is a fundamental approach for describing the complex irregularities of the spatial structure of point patterns. The present research characterizes the spatial structure of the Swiss population distribution in the three Swiss geographical regions (Alps, Plateau and Jura) and at the entire country level. These analyses were carried out using fractal and multifractal measures for point patterns, which enabled the estimation of the spatial degree of clustering of a distribution at different scales. The Swiss population dataset is presented on a grid of points and thus it can be modelled as a "point process" where each point is characterized by its spatial location (geometrical support) and a number of inhabitants (measured variable). The fractal characterization was performed by means of the box-counting dimension and the multifractal analysis was conducted through the Renyi's generalized dimensions and the multifractal spectrum. Results showed that the four population patterns are all multifractals and present different clustering behaviours. Applying multifractal and fractal methods at different geographical regions and at different scales allowed us to quantify and describe the dissimilarities between the four structures and their underlying processes. This paper is the first Swiss geodemographic study applying multifractal methods using high resolution data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The progressive development of Alzheimer's disease (AD)-related lesions such as neurofibrillary tangles,amyloid deposits and synaptic loss within the cerebral cortex is a main event of brain aging.Recent neuropathologic studies strongly suggested that the clinical diagnosis of dementia depends more on the severity and topography of pathologic changes than on the presence of a qualitative marker. However, several methodological problems such as selection biases, case-control design,density-based measures, and masking effects of concomitant pathologies should be taken into account when interpreting these data. In last years, the use of stereologic counting permitted to define reliably the cognitive impact of AD lesions in the human brain. Unlike fibrillar amyloid deposits that are poorly or not related to the dementia severity, the use of this method documented that total neurofibrillary tangles and neuron numbers in the CA1 field are the best correlates of cognitive deterioration in brain aging. Loss of dendritic spines in neocortical but not hippocampal areas has a modest but independent contribution to dementia. In contrast, the importance of early dendritic and axonal tau-related pathologic changes such as neuropil threads remains doubtful. Despite these progresses, neuronal pathology and synaptic loss in cases with pure AD pathology cannot explain more than 50% of clinical severity. The present review discusses the complex structure/function relationships in brain aging and AD within the theoretical framework of the functional neuropathology of brain aging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As part of a project to use the long-lived (T(1/2)=1200a) (166m)Ho as reference source in its reference ionisation chamber, IRA standardised a commercially acquired solution of this nuclide using the 4pibeta-gamma coincidence and 4pigamma (NaI) methods. The (166m)Ho solution supplied by Isotope Product Laboratories was measured to have about 5% Europium impurities (3% (154)Eu, 0.94% (152)Eu and 0.9% (155)Eu). Holmium had therefore to be separated from europium, and this was carried out by means of ion-exchange chromatography. The holmium fractions were collected without europium contamination: 162h long HPGe gamma measurements indicated no europium impurity (detection limits of 0.01% for (152)Eu and (154)Eu, and 0.03% for (155)Eu). The primary measurement of the purified (166m)Ho solution with the 4pi (PC) beta-gamma coincidence technique was carried out at three gamma energy settings: a window around the 184.4keV peak and gamma thresholds at 121.8 and 637.3keV. The results show very good self-consistency, and the activity concentration of the solution was evaluated to be 45.640+/-0.098kBq/g (0.21% with k=1). The activity concentration of this solution was also measured by integral counting with a well-type 5''x5'' NaI(Tl) detector and efficiencies computed by Monte Carlo simulations using the GEANT code. These measurements were mutually consistent, while the resulting weighted average of the 4pi NaI(Tl) method was found to agree within 0.15% with the result of the 4pibeta-gamma coincidence technique. An ampoule of this solution and the measured value of the concentration were submitted to the BIPM as a contribution to the Système International de Référence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several authors have demonstrated an increased number of mitotic figures in breast cancer resection specimen when compared with biopsy material. This has been ascribed to a sampling artifact where biopsies are (i) either too small to allow formal mitotic figure counting or (ii) not necessarily taken form the proliferating tumor periphery. Herein, we propose a different explanation for this phenomenon. Biopsy and resection material of 52 invasive ductal carcinomas was studied. We counted mitotic figures in 10 representative high power fields and quantified MIB-1 immunohistochemistry by visual estimation, counting and image analysis. We found that mitotic figures were elevated by more than three-fold on average in resection specimen over biopsy material from the same tumors (20±6 vs 6±2 mitoses per 10 high power fields, P=0.008), and that this resulted in a relative diminution of post-metaphase figures (anaphase/telophase), which made up 7% of all mitotic figures in biopsies but only 3% in resection specimen (P<0.005). At the same time, the percentages of MIB-1 immunostained tumor cells among total tumor cells were comparable in biopsy and resection material, irrespective of the mode of MIB-1 quantification. Finally, we found no association between the size of the biopsy material and the relative increase of mitotic figures in resection specimen. We propose that the increase in mitotic figures in resection specimen and the significant shift towards metaphase figures is not due to a sampling artifact, but reflects ongoing cell cycle activity in the resected tumor tissue due to fixation delay. The dwindling energy supply will eventually arrest tumor cells in metaphase, where they are readily identified by the diagnostic pathologist. Taken together, we suggest that the rapidly fixed biopsy material better represents true tumor biology and should be privileged as predictive marker of putative response to cytotoxic chemotherapy.