44 resultados para augmented reality
em Universit
Resumo:
OBJECTIVE: Our aim was to evaluate a fluorescence-based enhanced-reality system to assess intestinal viability in a laparoscopic mesenteric ischemia model. MATERIALS AND METHODS: A small bowel loop was exposed, and 3 to 4 mesenteric vessels were clipped in 6 pigs. Indocyanine green (ICG) was administered intravenously 15 minutes later. The bowel was illuminated with an incoherent light source laparoscope (D-light-P, KarlStorz). The ICG fluorescence signal was analyzed with Ad Hoc imaging software (VR-RENDER), which provides a digital perfusion cartography that was superimposed to the intraoperative laparoscopic image [augmented reality (AR) synthesis]. Five regions of interest (ROIs) were marked under AR guidance (1, 2a-2b, 3a-3b corresponding to the ischemic, marginal, and vascularized zones, respectively). One hour later, capillary blood samples were obtained by puncturing the bowel serosa at the identified ROIs and lactates were measured using the EDGE analyzer. A surgical biopsy of each intestinal ROI was sent for mitochondrial respiratory rate assessment and for metabolites quantification. RESULTS: Mean capillary lactate levels were 3.98 (SD = 1.91) versus 1.05 (SD = 0.46) versus 0.74 (SD = 0.34) mmol/L at ROI 1 versus 2a-2b (P = 0.0001) versus 3a-3b (P = 0.0001), respectively. Mean maximal mitochondrial respiratory rate was 104.4 (±21.58) pmolO2/second/mg at the ROI 1 versus 191.1 ± 14.48 (2b, P = 0.03) versus 180.4 ± 16.71 (3a, P = 0.02) versus 199.2 ± 25.21 (3b, P = 0.02). Alanine, choline, ethanolamine, glucose, lactate, myoinositol, phosphocholine, sylloinositol, and valine showed statistically significant different concentrations between ischemic and nonischemic segments. CONCLUSIONS: Fluorescence-based AR may effectively detect the boundary between the ischemic and the vascularized zones in this experimental model.
Resumo:
The mouse has emerged as an animal model for many diseases. At IRO, we have used this animal to understand the development of many eye diseases and treatment of some of them. Precise evaluation of vision is a prerequisite for both these approaches. In this unit we describe three ways to measure vision: testing the optokinetic response, and evaluating the fundus by direct observation and by fluorescent angiography.
Performance on a Virtual Reality Angled Laparoscope Task Correlates with Spatial Ability of Trainees
Resumo:
The aim of the present study was to investigate whether trainees' performance on a virtual reality angled laparoscope navigation task correlates with scores obtained on a validated conventional test of spatial ability. 56 participants of a surgery workshop performed an angled laparoscope navigation task on the Xitact LS 500 virtual reality Simulator. Performance parameters were correlated with the score of a validated paper-and-pencil test of spatial ability. Performance at the conventional spatial ability test significantly correlated with performance at the virtual reality task for overall task score (p < 0.001), task completion time (p < 0.001) and economy of movement (p = 0.035), not for endoscope travel speed (p = 0.947). In conclusion, trainees' performance in a standardized virtual reality camera navigation task correlates with their innate spatial ability. This VR session holds potential to serve as an assessment tool for trainees.
Resumo:
OBJECTIVE: To compare the expression of the prostaglandin (PG) E(2) transporter multidrug resistance-associated protein 4 (MRP4) in eutopic and ectopic endometrial tissue from endometriosis patients with that of control subjects and to examine whether MRP4 is regulated by the antiinflammatory lipid lipoxin A(4) (LXA(4)) in endometriotic epithelial cells. DESIGN: Molecular analysis in human samples and a cell line. SETTING: Two university hospitals and a private clinic. PATIENT(S): A total of 59 endometriosis patients and 32 age- and body mass index-matched control subjects undergoing laparoscopy or hysterectomy. INTERVENTION(S): Normal, eutopic, and ectopic endometrial biopsies as well as peritoneal fluid were obtained during surgery performed during the proliferative phase of the menstrual cycle. 12Z endometriotic epithelial cells were used for in vitro mechanistic studies. MAIN OUTCOME MEASURE(S): Tissue MRP4 mRNA levels were quantified by quantitative reverse-transcription polymerase chain reaction (qRT-PCR), and localization was analyzed with the use of immunohistochemistry. Cellular MRP4 mRNA and protein were quantified by qRT-PCR and Western blot, respectively. PGE(2) was measured in peritoneal fluid and cell supernatants using an enzyme immunoassay (EIA). RESULT(S): MRP4 was expressed in eutopic and ectopic endometrium, where it was overexpressed in peritoneal lesions and localized in the cytoplasm of glandular epithelial cells. LXA(4) attenuated MRP4 mRNA and protein levels in endometriotic epithelial cells in a dose-dependent manner, while not affecting the expression of enzymes involved in PGE(2) metabolism. Investigations employing receptor antagonists and small interfering RNA revealed that this occurred through estrogen receptor α. Accordingly, LXA(4) treatment inhibited extracellular PGE(2) release. CONCLUSION(S): We report for the first time that MRP4 is expressed in human endometrium, elevated in peritoneal endometriosis, and modulated by LXA(4) in endometriotic epithelial cells.
Resumo:
Introduction. Preoperative malnutrition is a major risk factor for increased postoperative morbidity and mortality. Definition and diagnosis of malnutrition and its treatment is still subject for controversy. Furthermore, practical implementation of nutrition-related guidelines is unknown. Methods. A review of the available literature and of current guidelines on perioperative nutrition was conducted. We focused on nutritional screening and perioperative nutrition in patients undergoing digestive surgery, and we assessed translation of recent guidelines in clinical practice. Results and Conclusions. Malnutrition is a well-recognized risk factor for poor postoperative outcome. The prevalence of malnutrition depends largely on its definition; about 40% of patients undergoing major surgery fulfil current diagnostic criteria of being at nutritional risk. The Nutritional Risk Score is a pragmatic and validated tool to identify patients who should benefit from nutritional support. Adequate nutritional intervention entails reduced (infectious) complications, hospital stay, and costs. Preoperative oral supplementation of a minimum of five days is preferable; depending on the patient and the type of surgery, immune-enhancing formulas are recommended. However, surgeons' compliance with evidence-based guidelines remains poor and efforts are necessary to implement routine nutritional screening and nutritional support.
Resumo:
Background: In children, video game experience improves spatial performance, a predictor of surgical performance. This study aims at comparing laparoscopic virtual reality (VR) task performance of children with different levels of experience in video games and residents. Participants and methods: A total of 32 children (8.4 to 12.1 years), 20 residents, and 14 board-certified surgeons (total n = 66) performed several VR and 2 conventional tasks (cube/spatial and pegboard/fine motor). Performance between the groups was compared (primary outcome). VR performance was correlated with conventional task performance (secondary outcome). Results: Lowest VR performance was found in children with low video game experience, followed by those with high video game experience, residents, and board-certified surgeons. VR performance correlated well with the spatial test and moderately with the fine motor test. Conclusions: The use of computer games can be considered not only as pure entertainment but may also contribute to the development of skills relevant for adequate performance in VR laparoscopic tasks. Spatial skills are relevant for VR laparoscopic task performance.
Resumo:
A previously described extract of sheep fetal liver was reported to reverse many of the cytokine changes associated with aging in mice, including an augmented spleen cell ConA-stimulated production of IL-4 and decreased production of IL-2. Similar effects were not seen with adult liver preparations. These changes were observed in various strains of mice, including BALB/c, DBA/2 and C57BL/6, using mice with ages ranging from 8 to 110 weeks. Preliminary characterization of this crude extract showed evidence for the presence of Hb gamma chain, as well as of lipid A of LPS. We show below that purified preparations of sheep fetal Hb, but not adult Hb, in concert with suboptimally stimulating doses of LPS (lipid A), cooperate in the regulation of production of a number of cytokines, including TNFalpha and IL-6, in vitro. Furthermore, isolated fresh spleen or peritoneal cells from animals treated in vivo with the same combination of Hb and LPS, showed an augmented capacity to produce these cytokines on further culture in vitro. Evidence was also obtained for a further interaction between CLP, LPS and fetal Hb itself in this augmented cytokine production. These data suggest that some of the functional activities in the fetal liver extract reported earlier can be explained in terms of a novel immunomodulatory role of a mixture of LPS (lipid A) and fetal Hb.
Resumo:
BACKGROUND: Surgeons' personalities have been described as different from those of the general population, but this was based on small descriptive studies limited by the choice of evaluation instrument. Furthermore, although the importance of the human factor in team performance has been recognized, the effect of personality traits on technical performance is unknown. This study aimed to compare surgical residents' personality traits with those of the general population and to evaluate whether an association exists between their personality traits and technical performance using a virtual reality (VR) laparoscopy simulator. METHODS: In this study, 95 participants (54 residents with basic, 29 with intermediate laparoscopic experience, and 12 students) underwent personality assessment using the NEO-Five Factor Inventory and performed five VR tasks of the Lap Mentor? basic tasks module. The residents' personality traits were compared with those of the general population, and the association between VR performance and personality traits was investigated. RESULTS: Surgical residents showed personality traits different from those of the general population, demonstrating lower neuroticism, higher extraversion and conscientiousness, and male residents showed greater openness. In the multivariable analysis, adjusted for gender and surgical experience, none of the personality traits was found to be an independent predictor of technical performance. CONCLUSIONS: Surgical residents present distinct personality traits that differ from those of the general population. These traits were not found to be associated with technical performance in a virtual environment. The traits may, however, play an important role in team performance, which in turn is highly relevant for optimal surgical performance.
Resumo:
INTRODUCTION: The endogenous opioid system has been reported to interact with both the cardiac sympathetic and renin-angiotensin systems in exerting a local regulatory action on the heart. The goal of this investigation was to examine how cardiac levels of enkephalin production are altered in the development of normotensive primary hypertrophy due to elevated intra-cardiac angiotensin II (Ang II) production. METHODS: Atrial and ventricular methionine-enkephalin (ME) levels were measured by quantitative radioimmunoassay in 14 and 28-week-old male transgenic mice (TG1306/1R) and control mice. The TG1306/1R exhibit cardiac specific Ang II overexpression and cardiac hypertrophy, but not hypertension. RESULTS: TG1306/1R mice had significantly higher heart/body weight ratios (15-20%) than control littermates at both 14 (p=0.02) and 28 weeks (p=0.04). Relative to controls, ME content was significantly elevated (approximately two-fold) in atria and ventricles in the older 28-week TG1306/1R mice only. A significant inverse correlation between heart size and ME level was observed for 28-week TG1306/1R only. CONCLUSIONS: We have provided evidence that a marked elevation of myocardial enkephalin level is observed in the established (but not early) phase of cardiac hypertrophy associated with cardiac-specific Ang II-overexpression. This study identifies a potentially important relationship between two endogenous peptidergic signalling systems involved in the regulation of growth and function of the hypertrophic heart.
Resumo:
BACKGROUND: The aim of this study was to assess whether virtual reality (VR) can discriminate between the skills of novices and intermediate-level laparoscopic surgical trainees (construct validity), and whether the simulator assessment correlates with an expert's evaluation of performance. METHODS: Three hundred and seven (307) participants of the 19th-22nd Davos International Gastrointestinal Surgery Workshops performed the clip-and-cut task on the Xitact LS 500 VR simulator (Xitact S.A., Morges, Switzerland). According to their previous experience in laparoscopic surgery, participants were assigned to the basic course (BC) or the intermediate course (IC). Objective performance parameters recorded by the simulator were compared to the standardized assessment by the course instructors during laparoscopic pelvitrainer and conventional surgery exercises. RESULTS: IC participants performed significantly better on the VR simulator than BC participants for the task completion time as well as the economy of movement of the right instrument, not the left instrument. Participants with maximum scores in the pelvitrainer cholecystectomy task performed the VR trial significantly faster, compared to those who scored less. In the conventional surgery task, a significant difference between those who scored the maximum and those who scored less was found not only for task completion time, but also for economy of movement of the right instrument. CONCLUSIONS: VR simulation provides a valid assessment of psychomotor skills and some basic aspects of spatial skills in laparoscopic surgery. Furthermore, VR allows discrimination between trainees with different levels of experience in laparoscopic surgery establishing construct validity for the Xitact LS 500 clip-and-cut task. Virtual reality may become the gold standard to assess and monitor surgical skills in laparoscopic surgery.
Resumo:
The need for an early neurorehabilitation pathway was identified in an acute university hospital. A team was formed to draw up and implement it. A neuro-sensorial, interdisciplinary and coordinated therapy program was developed, focused on tracheostomised patients as soon as they were admitted to the intermediate care in neurology and neurosurgery. The impact of this care plan was evaluated by comparing the results obtained with that pertaining to patients treated previously in the same services. The comparison showed a reduction of 48% of the mean duration of tracheostomy, of 39% in the time to inscription in a neurorehabilitation centre and of 20% in the length of stay in the intermediate care. An early neurorehabilitation care program, with an interdisciplinary and coordinated team, reduces complications and lengths of stay.
Resumo:
Non-steroidal anti-inflammatory drugs (NSAIDs) and specific inhibitors of cyclooxygenase (COX)-2, are therapeutic groups widely used for the treatment of pain, inflammation and fever. There is growing experimental and clinical evidence indicating NSAIDs and COX-2 inhibitors also have anti-cancer activity. Epidemiological studies have shown that regular use of Aspirin and other NSAIDs reduces the risk of developing cancer, in particular of the colon. Molecular pathology studies have revealed that COX-2 is expressed by cancer cells and cells of the tumor stroma during tumor progression and in response to chemotherapy or radiotherapy. Experimental studies have demonstrated that COX-2 over expression promotes tumorigenesis, and that NSAIDs and COX-2 inhibitors suppress tumorigenesis and tumor progression. Clinical trials have shown that NSAIDs and COX-2 inhibitors suppress colon polyp formation and malignant progression in patients with familial adenomatous polyposis (FAP) syndrome. Recent advances in the understanding of the cellular and molecular mechanisms of the anti-cancer effects of NSAIDs and COX-2 inhibitors have demonstrated that these drugs target both tumor cells and the tumor vasculature. The therapeutic benefits of COX-2 inhibitors in the treatment of human cancer in combination with chemotherapy or radiotherapy are currently being tested in clinical trials. In this article we will review recent advances in the understanding of the anti-tumor mechanisms of these drugs and discuss their potential application in clinical oncology.
Resumo:
Decision to revascularize a patient with stable coronary artery disease should be based on the detection of myocardial ischemia. If this decision can be straightforward with significant stenosis or in non-significant stenosis, the decision with intermediate stenosis is far more difficult and require invasive measures of functional impact of coronary stenosis on maximal blood (flow fractional flow reserve=FFR). A recent computer based method has been developed and is able to measure FFR with data acquired during a standard coronary CT-scan (FFRcT). Two recent clinical studies (DeFACTO and DISCOVER-FLOW) show that diagnostic performance of FFRcT was associated with improved diagnostic accuracy versus standard coronary CT-scan for the detection of myocardial ischemia although FFRcT need further development.
Resumo:
BACKGROUND: Virtual reality (VR) simulators are widely used to familiarize surgical novices with laparoscopy, but VR training methods differ in efficacy. In the present trial, self-controlled basic VR training (SC-training) was tested against training based on peer-group-derived benchmarks (PGD-training). METHODS: First, novice laparoscopic residents were randomized into a SC group (n = 34), and a group using PGD-benchmarks (n = 34) for basic laparoscopic training. After completing basic training, both groups performed 60 VR laparoscopic cholecystectomies for performance analysis. Primary endpoints were simulator metrics; secondary endpoints were program adherence, trainee motivation, and training efficacy. RESULTS: Altogether, 66 residents completed basic training, and 3,837 of 3,960 (96.8 %) cholecystectomies were available for analysis. Course adherence was good, with only two dropouts, both in the SC-group. The PGD-group spent more time and repetitions in basic training until the benchmarks were reached and subsequently showed better performance in the readout cholecystectomies: Median time (gallbladder extraction) showed significant differences of 520 s (IQR 354-738 s) in SC-training versus 390 s (IQR 278-536 s) in the PGD-group (p < 0.001) and 215 s (IQR 175-276 s) in experts, respectively. Path length of the right instrument also showed significant differences, again with the PGD-training group being more efficient. CONCLUSIONS: Basic VR laparoscopic training based on PGD benchmarks with external assessment is superior to SC training, resulting in higher trainee motivation and better performance in simulated laparoscopic cholecystectomies. We recommend such a basic course based on PGD benchmarks before advancing to more elaborate VR training.